AWWA C905 2010
$75.83
AWWA C905-10: Polyvinyl Chloride (PVC) Pressure Pipe & Fabricated Fittings, 14 In Thru 48 In (350 MM Thru 1,200 MM) For Water Transmission And Distribution
Published By | Publication Date | Number of Pages |
AWWA | 2010 | 40 |
Pipe manufactured to this standard is generally well suited for conveying potable water, reclaimed water, irrigation water, wastewater, or any fluid compatible with non-plasticized PVC. The standard includes eight dimension ratio (DRs) and nominal pipe sizes ranging from 14 in. through 48 in. (350 mm through 1,200 mm). Pipe outside diameters (ODs) conform to those established for CI-equivalent ODs (CIOD) and steel-pipe-equivalent ODs (IPS). Pressure classes range from 80 psi (550 kPa) to 305 psi (2,100 kPa).
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | ANSI/AWWA C905-10 |
3 | Committee Personnel |
5 | Contents |
7 | Foreword I. Introduction. |
9 | II. Special Issues. III. Use of This Standard. |
10 | IV. Major Revisions. |
11 | V. Comments. |
13 | AWWA Standard Polyvinyl Chloride (PVC) Pressure Pipe and Fabricated Fittings, 14 In. Through 48 In. (350 mm Through 1,200 mm) SECTION 1: GENERAL Sec. 1.1 Scope Sec. 1.2 Purpose |
14 | Sec. 1.3 Application SECTION 2: REFERENCES |
15 | SECTION 3: DEFINITIONS |
19 | SECTION 4: REQUIREMENTS Sec. 4.1 Permeation Sec. 4.2 Materials |
20 | Sec. 4.3 Pipe Requirements |
21 | Table 1-A Dimensions, pressure classes, and dimension ratios for PVC pipe with IPS outside diameter |
22 | Table 1-B Dimensions, pressure classes, and dimension ratios for PVC pipe with CI outside diameter (continued) |
23 | Table 1-B Dimensions, pressure classes, and dimension ratios for PVC pipe with CI outside diameter (continued) |
24 | Table 2 Pressure-test requirements |
25 | Table 3 Temperature coefficients, F Sec. 4.4 Machined Coupling Requirements |
26 | Sec. 4.5 Fabricated Fitting Requirements |
28 | Sec. 4.6 Joint Requirements Sec. 4.7 Pressure Rating Designations |
29 | Table 4 Allowable maximum occasional surge pressure capacity and allowable sudden changes in water velocity for pipe operating at 73°F at working pressures expressed as percent of nominal pressure class (PC) |
30 | SECTION 5: VERIFICATION Sec. 5.1 Quality-Control and Qualification Test Requirements |
32 | Sec. 5.2 Quality Control Records |
33 | Sec. 5.3 Plant Inspection SECTION 6: DELIVERY Sec. 6.1 Marking |
34 | Sec. 6.2 Shipping and Delivery Sec. 6.3 Notice of Nonconformance Sec. 6.4 Affidavit of Compliance |
35 | APPENDIX A Bibliography |
37 | APPENDIX B Recurring (Cyclic) Surge-Figures and Design Example SECTION B.1: DISCUSSION SECTION B.2: DESIGN EXAMPLE |