Shopping Cart

No products in the cart.

AWWA C905 2010

$75.83

AWWA C905-10: Polyvinyl Chloride (PVC) Pressure Pipe & Fabricated Fittings, 14 In Thru 48 In (350 MM Thru 1,200 MM) For Water Transmission And Distribution

Published By Publication Date Number of Pages
AWWA 2010 40
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Pipe manufactured to this standard is generally well suited for conveying potable water, reclaimed water, irrigation water, wastewater, or any fluid compatible with non-plasticized PVC. The standard includes eight dimension ratio (DRs) and nominal pipe sizes ranging from 14 in. through 48 in. (350 mm through 1,200 mm). Pipe outside diameters (ODs) conform to those established for CI-equivalent ODs (CIOD) and steel-pipe-equivalent ODs (IPS). Pressure classes range from 80 psi (550 kPa) to 305 psi (2,100 kPa).

PDF Catalog

PDF Pages PDF Title
1 ANSI/AWWA C905-10
3 Committee Personnel
5 Contents
7 Foreword
I. Introduction.
9 II. Special Issues.
III. Use of This Standard.
10 IV. Major Revisions.
11 V. Comments.
13 AWWA Standard Polyvinyl Chloride (PVC) Pressure
Pipe and Fabricated Fittings, 14 In.
Through 48 In. (350 mm Through
1,200 mm)

SECTION 1: GENERAL
Sec. 1.1 Scope
Sec. 1.2 Purpose
14 Sec. 1.3 Application
SECTION 2: REFERENCES
15 SECTION 3: DEFINITIONS
19 SECTION 4: REQUIREMENTS
Sec. 4.1 Permeation
Sec. 4.2 Materials
20 Sec. 4.3 Pipe Requirements
21 Table 1-A Dimensions, pressure classes, and dimension ratios for PVC pipe with IPS outside
diameter
22 Table 1-B Dimensions, pressure classes, and dimension ratios for PVC pipe with CI outside
diameter (continued)
23 Table 1-B Dimensions, pressure classes, and dimension ratios for PVC pipe with CI outside
diameter (continued)
24 Table 2 Pressure-test requirements
25 Table 3 Temperature coefficients, F
Sec. 4.4 Machined Coupling Requirements
26 Sec. 4.5 Fabricated Fitting Requirements
28 Sec. 4.6 Joint Requirements
Sec. 4.7 Pressure Rating Designations
29 Table 4 Allowable maximum occasional surge pressure capacity and allowable sudden
changes in water velocity for pipe operating at 73°F at working pressures expressed as percent
of nominal pressure class (PC)
30 SECTION 5: VERIFICATION
Sec. 5.1 Quality-Control and Qualification Test Requirements
32 Sec. 5.2 Quality Control Records
33 Sec. 5.3 Plant Inspection
SECTION 6: DELIVERY
Sec. 6.1 Marking
34 Sec. 6.2 Shipping and Delivery
Sec. 6.3 Notice of Nonconformance
Sec. 6.4 Affidavit of Compliance
35 APPENDIX A Bibliography
37 APPENDIX B Recurring (Cyclic) Surge-Figures and Design Example

SECTION B.1: DISCUSSION
SECTION B.2: DESIGN EXAMPLE
AWWA C905 2010
$75.83