Shopping Cart

No products in the cart.

AWWA C907 2012

$75.83

AWWA C907-12: Polyvinyl Chloride (PVC) Pressure Fittings For Water 4 Inch Thru 8 Inch (100 MM Thru 200 MM) For Water Distribution

Published By Publication Date Number of Pages
AWWA 2012 32
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This standard describes Pressure Class 150 polyvinyl chloride (PVC) injection-molded fittings with push-on, rubber-gasketed joints in nominal sizes 4 in. through 12 in. (100 mm through 300 mm). The fittings are for use with PVC water distribution pipe having an outside diameter conforming to the dimensions of cast-iron pipe and with dimension ratios (DR) of 18 (Class 150) or 25 (Class 100), as described in ANSI/AWWA C900, Standard for Polyvinyl Chloride (PVC) Pressure Pipe and Fabricated Fittings, 4 in. Through 12 in. (100 mm Through 300 mm), for Water Distribution. Major changes made to the standard in this revision include the following: the inclusion of 10-in. (250-mm) repair and line couplings; the inclusion of 4-in. (100-mm), 6-in. (150-mm), and 8-in. (200-mm) single-tapped and double-tapped couplings; the inclusion of 4-in. through 8-in. (100-mm through 200-mm) 11

PDF Catalog

PDF Pages PDF Title
1 ANSI/AWWA C907-12
3 Committee Personnel
5 Contents
7 Foreword
I. Introduction.
9 II. Special Issues.
III. Use of This Standard.
IV. Major Revisions.
10 V. Comments.
11 AWWA Standard Injection-Molded Polyvinyl Chloride
(PVC) Pressure Fittings, 4 In.
Through 12 In. (100 mm Through
300 mm), for Water, Wastewater, and
Reclaimed Water Service

SECTION 1: GENERAL
Sec. 1.1 Scope
12 Sec. 1.2 Purpose
Sec. 1.3 Application
SECTION 2: REFERENCES
13 SECTION 3: DEFINITIONS
15 SECTION 4: REQUIREMENTS
Sec. 4.1 Permeation
Sec. 4.2 Materials
16 Sec. 4.3 Fitting Requirements
17 Table 1 Wall thicknesses, bell depths, and inside diameters of PVC fittings (refer to Figure 1)
18 Table 2 Tees and reducing tees
19 Table 3 11-1/4° bends (B × B)

Table 4 22-1/2° bends (B × B)

Table 5 45° bends (B × B)
20 Table 6 45° bends (B × Sp)

Table 7 90° bends (B × B)

Table 8 Increaser/reducer coupling (B × Sp)

Table 10 Repair coupling (B × B)
21 Table 9 Line coupling (B × B)
Table 11 Single-tapped coupling (B × B × AWWA)
Table 12 Single-tapped coupling (B × B × AWWA)
22 Table 13 Double-tapped coupling (B × B × AWWA × AWWA)
Table 14 Plug (Sp)
23 Table 15 Tapped plug (Sp × NPT)
Table 16 IPS × CI Adapter (B × Sp)
24 Table 17 Cap (B)
Table 18 Hydrant Tees
25 Sec. 4.4 Pressure Class of Fittings
Sec. 4.5 Pressure Class Thermal Derating Factors
26 Table 19 Temperature coefficients
Sec. 4.6 Transient Surge Pressure
SECTION 5: VERIFICATION
Sec. 5.1 Test Methods
27 Table 20 Allowable maximum occasional surge pressure capacity and allowable sudden
changes in water velocity for pipe operating at 73°F at working pressures expressed as percent
of nominal pressure class (PC)*
30 Sec. 5.2 Inspection
SECTION 6: DELIVERy
Sec. 6.1 Marking
31 Sec. 6.2 Shipping and Delivery
Sec. 6.3 Affidavit of Compliance
AWWA C907 2012
$75.83