Shopping Cart

No products in the cart.

AZ Phoenix City MechanicalCode 2006

$37.38

International Mechanical Code: As Amended by the City of Phoenix

Published By Publication Date Number of Pages
AZ 2006 136
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The 2006 International Mechanical Code® fully integrated with the City of Phoenix amendments

PDF Catalog

PDF Pages PDF Title
1 WELCOME PAGE
INTERNATIONAL MECHANICAL CODE® 2006 AS AMENDED BY THE CITY OF PHOENIX
2 COPYRIGHT
3 PREFACE
5 ORDINANCE
7 TABLE OF CONTENTS
11 CHAPTER 1 ADMINISTRATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY
12 SECTION 103 DEPARTMENT OF MECHANICAL INSPECTION
SECTION 104 DUTIES AND POWERS OF THE CODE OFFICIAL
SECTION 105 APPROVAL
13 SECTION 106 PERMITS
14 SECTION 107 INSPECTIONS AND TESTING
15 SECTION 108 VIOLATIONS
16 SECTION 109 MEANS OF APPEAL
19 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
29 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 GENERAL
30 SECTION 302 PROTECTION OF STRUCTURE
31 SECTION 303 EQUIPMENT AND APPLIANCE LOCATION
SECTION 304 INSTALLATION
32 SECTION 305 PIPING SUPPORT
33 TABLE 305.4 PIPING SUPPORT SPACINGa
SECTION 306 ACCESS AND SERVICE SPACE
34 SECTION 307 CONDENSATE DISPOSAL
35 SECTION 308 CLEARANCE REDUCTION
36 TABLE 308.6 CLEARANCE REDUCTION METHODS
[B] SECTION 309 TEMPERATURE CONTROL
37 [F] SECTION 310 EXPLOSION CONTROL
[F] SECTION 311 SMOKE AND HEAT VENTS
SECTION 312 HEATING AND COOLING LOAD CALCULATIONS
39 CHAPTER 4 VENTILATION
SECTION 401 GENERAL
TABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING OUTDOOR EXHAUST AND AIR INTAKE OPENINGS
[B] SECTION 402 NATURAL VENTILATION
40 SECTION 403 MECHANICAL VENTILATION
(EQUATION 4-1)
41 TABLE 403.3 REQUIRED OUTDOOR VENTILATION AIR
SECTION 404 ENCLOSED PARKING GARAGES
SECTION 405 SYSTEMS CONTROL
SECTION 406 VENTILATION OF UNINHABITED SPACES
42 TABLE 403.3—continued REQUIRED OUTDOOR VENTILATION AIR
TABLE 403.3—continued REQUIRED OUTDOOR VENTILATION AIR
43 SECTION 407 EVAPORATIVE COOLING SYSTEMS
45 CHAPTER 5 EXHAUST SYSTEMS
SECTION 501 GENERAL
SECTION 502 REQUIRED SYSTEMS
46 EQUATION 5-1
51 SECTION 503 MOTORS AND FANS
52 SECTION 504 CLOTHES DRYER EXHAUST
53 SECTION 505 DOMESTIC KITCHEN EXHAUST EQUIPMENT
SECTION 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT
56 SECTION 507 COMMERCIAL KITCHEN HOODS
57 TABLE 507.11 MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE
59 SECTION 508 COMMERCIAL KITCHEN MAKEUP AIR
SECTION 509 FIRE SUPPRESSION SYSTEMS
SECTION 510 HAZARDOUS EXHAUST SYSTEMS
61 TABLE 510.8 MINIMUM DUCT THICKNESS
TABLE 510.8.2 CLEARANCE TO COMBUSTIBLES
SECTION 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS
62 TABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL CHIMNEYS
SECTION 512 SUBSLAB SOIL EXHAUST SYSTEMS
SECTION 513 SMOKE CONTROL SYSTEMS
64 (EQUATION 5-2)
(EQUATION 5-3)
(EQUATION 5-4)
66 SECTION 514 ENERGY RECOVERY VENTILATION SYSTEMS
67 CHAPTER 6 DUCT SYSTEMS
SECTION 601 GENERAL
SECTION 602 PLENUMS
68 SECTION 603 DUCT CONSTRUCTION AND INSTALLATION
69 TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESSES FOR SINGLE DWELLING UNITS
70 SECTION 604 INSULATION
71 SECTION 605 AIR FILTERS
SECTION 606 SMOKE DETECTION SYSTEMS CONTROL
72 [B] SECTION 607 DUCT AND TRANSFER OPENINGS
TABLE 607.3.1 FIRE DAMPER RATING
79 CHAPTER 7 COMBUSTION AIR
SECTION 701 GENERAL
SECTION 702 INDOOR AIR
SECTION 703 OUTDOOR AIR
80 SECTION 704 COMBINED USE OF INDOOR AND OUTDOOR AIR (CONDITION 1)
SECTION 705 COMBINED USE OF INDOOR AND OUTDOOR AIR (CONDITION 2)
SECTION 706 FORCED COMBUSTION AIR SUPPLY
SECTION 707 DIRECT CONNECTION
81 SECTION 708 COMBUSTION AIR DUCTS SECTION 710
SECTION 709 OPENING OBSTRUCTIONS
SECTION 710 OPENING LOCATION AND PROTECTION
83 CHAPTER 8 CHIMNEYS AND VENTS
SECTION 801 GENERAL
84 SECTION 802 VENTS
TABLE 802.2 VENT APPLICATION
85 SECTION 803 CONNECTORS
TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES
TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES
86 TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCESa,b,c,d
TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES
SECTION 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS
87 SECTION 805 FACTORY-BUILT CHIMNEYS
88 SECTION 806 METAL CHIMNEYS
89 CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT
SECTION 901 GENERAL
SECTION 902 MASONRY FIREPLACES
SECTION 903 FACTORY-BUILT FIREPLACES INCINERATORS AND CREMATORIES
SECTION 904 PELLET FUEL-BURNING APPLIANCES
SECTION 905 FIREPLACE STOVES AND ROOM HEATERS
SECTION 906 FACTORY-BUILT BARBECUE APPLIANCES
SECTION 907 INCINERATORS AND CREMATORIES
SECTION 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS
90 SECTION 909 VENTED WALL FURNACES
SECTION 910 FLOOR FURNACES
SECTION 911 DUCT FURNACES
SECTION 912 INFRARED RADIANT HEATERS
SECTION 913 CLOTHES DRYERS
91 SECTION 914 SAUNA HEATERS
SECTION 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES
SECTION 916 POOL AND SPA HEATERS
SECTION 917 COOKING APPLIANCES
SECTION 918 FORCED-AIR WARM-AIR FURNACES
92 SECTION 919 CONVERSION BURNERS
SECTION 920 UNIT HEATERS
SECTION 921 VENTED ROOM HEATERS
93 SECTION 922 KEROSENE AND OIL-FIRED STOVES
SECTION 923 SMALL CERAMIC KILNS
SECTION 924 STATIONARY FUEL CELL POWER SYSTEMS
SECTION 925 MASONRY HEATERS
SECTION 926 GASEOUS HYDROGEN SYSTEMS
SECTION 927 WOODSTOVE/FIREPLACE INSTALLATIONS
95 CHAPTER 10 BOILERS,WATER HEATERS AND PRESSURE VESSELS
SECTION 1001 GENERAL
SECTION 1002 WATER HEATERS
SECTION 1003 PRESSURE VESSELS
SECTION 1004 BOILERS
96 SECTION 1005 BOILER CONNECTIONS
SECTION 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS
SECTION 1007 BOILER LOW-WATER CUTOFF
97 SECTION 1008 STEAM BLOWOFF VALVE
SECTION 1009 HOT WATER BOILER EXPANSION TANK SECTION 1011
EQUATION 10-1
SECTION 1010 GAUGES
SECTION 1011 TESTS
99 CHAPTER 11 REFRIGERATION
SECTION 1101 GENERAL
SECTION 1102 SYSTEM REQUIREMENTS
100 SECTION 1103 REFRIGERATION SYSTEM CLASSIFICATION
SECTION 1104 SYSTEM APPLICATION REQUIREMENTS
101 [F]TABLE 1103.1 REFRIGERANT CLASSIFICATION, AMOUNT AND TLV-TWA
102 [F]TABLE 1103.1-continued REFRIGERANT CLASSIFICATION, AMOUNT AND TLV-TWA
103 [F]TABLE 1103.1-continued REFRIGERANT CLASSIFICATION, AMOUNT AND TLV-TWA
104 TABLE 1104.3.2 MAXIMUM PERMISSIBLE QUANTITIES OF REFRIGERANTS
105 SECTION 1105 MACHINERY ROOM, GENERAL REQUIREMENTS
EQUATION 11-1
106 EQUATION 11-2
SECTION 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS
SECTION 1107 REFRIGERANT PIPING
107 SECTION 1108 FIELD TEST
108 [F] SECTION 1109 PERIODIC TESTING
109 CHAPTER 12 HYDRONIC PIPING
SECTION 1201 GENERAL
SECTION 1202 MATERIAL
TABLE 1202.4 HYDRONIC PIPE
TABLE 1202.4-continued HYDRONIC PIPE
TABLE 1202.5 HYDRONIC PIPE FITTINGS
110 SECTION 1203 JOINTS AND CONNECTIONS
111 SECTION 1204 PIPE INSULATION
SECTION 1205 VALVES
SECTION 1206 PIPING INSTALLATION
112 SECTION 1207 TRANSFER FLUID
SECTION 1208 TESTS
SECTION 1209 EMBEDDED PIPING
113 CHAPTER 13 FUEL OIL PIPING AND STORAGE
SECTION 1301 GENERAL
SECTION 1302 MATERIAL
TABLE 1302.3 FUEL OIL PIPING
SECTION 1303 JOINTS AND CONNECTIONS
114 SECTION 1304 PIPING SUPPORT
SECTION 1305 FUEL OIL SYSTEM INSTALLATION
115 SECTION 1306 OIL GAUGING
SECTION 1307 FUEL OIL VALVES
SECTION 1308 TESTING
117 CHAPTER 14 SOLAR SYSTEMS
SECTION 1401 GENERAL
SECTION 1402 INSTALLATION
SECTION 1403 HEAT TRANSFER FLUIDS
118 SECTION 1404 MATERIALS
119 CHAPTER 15 REFERENCED STANDARDS
ACCA
ANSI
ARI
ASHRAE
ASME
120 ASSE
ASTM
121 AWS
122 CSA
DOL
FS
ICC
123 IIAR
MSS
NAIMA
NFPA
SMACNA
124 UL
125 APPENDIX A COMBUSTION AIR OPENINGS AND CHIMNEY CONNECTOR PASS-THROUGHS
FIGURE A-1 ALL AIR FROM INSIDE THE BUILDING
FIGURE A-2 ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC
126 FIGURE A-3 ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC
FIGURE A-4 ALL AIR FROM OUTDOORS THROUGH HORIZONTAL DUCTS OR DIRECT OPENINGS
127 FIGURE A-5 CHIMNEY CONNECTOR SYSTEMS
128 FIGURE A-5-continued CHIMNEY CONNECTOR SYSTEMS
129 APPENDIX B RECOMMENDED PERMIT FEE SCHEDULE
B101 MECHANICAL WORK, OTHER THAN GAS PIPING SYSTEMS
B102 FEE FOR REINSPECTION
B103 TEMPORARY OPERATION INSPECTION FEE
B104 SELF-CONTAINED UNITS LESS THAN 2 TONS
131 INDEX
AZ Phoenix City MechanicalCode 2006
$37.38