Shopping Cart

No products in the cart.

BIFMA X5.6 2016 RA2021

$81.25

ANSI/BIFMA X5.6-2016 (R2021) Panel Systems

Published By Publication Date Number of Pages
BIFMA 2016 121
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This standard is intended to provide a common basis for evaluating the safety, durability, and structural performance of panel systems products, such as panels, screens, panel-supported systems, access doors and various hang-on components used in conjunction with panel systems products. Building wall-mounted components are not covered by this standard; they are covered by the ANSI/BIFMA X5.9 Standard for Office Furniture Storage Units ? Tests. Where a product may be covered by more than one ANSI/BIFMA standard, the manufacturer shall determine which standard provides most appropriate test conditions. Where a product is intended for use outside of the commercial office and related institutional environments, it is the responsibility of the user of this standard to determine if it is suitable for use in such evaluations. This standard specifies acceptance levels to help ensure reasonable safety and performance independent of construction materials, manufacturing processes, mechanical designs, or aesthetic designs. The acceptance levels herein are based on the actual field and test experience of BIFMA members. This standard also provides recommendations for acoustical performance of panel systems products, and an Informative Annex that addresses considerations for Full-height Relocatable Wall products. The standard defines tests used to determine the acceptability of the product and specifies the acceptance levels of performance. These tests are not intended to assess a product that has been in use. The tests were developed with an estimated product life of ten years based on a single-shift usage. Product life will be affected by product use, care and maintenance, environment, and other factors. Product compliance to this standard does not necessarily guarantee a ten-year product life. Products may perform longer than ten years with appropriate use and care. ISO 17025 requirements for reporting uncertainty do not apply when determining conformance to this standard.

PDF Catalog

PDF Pages PDF Title
1 Cover
2 Copyright
3 ANSI Approval
4 Foreword
5 Contents
8 1 Scope
9 2 Definitions
13 3 General
3.1 Testing Considerations
15 3.2 Manufacturer’s Instructions
3.3 Clearance Between Adjustable Surfaces
3.4 Test Conditions and Restrictions
16 3.5 Figures
3.6 Figure Symbols
3.7 Tolerances
3.8 Pretest Inspection
17 3.9 Test Report Format
20 3.10 Loading Configurations
21 3.11 Temperature and Humidity Considerations
3.12 Glass Surfaces
22 Tables
1 Test Loads for Surfaces
23 4 Panel Flammability Test
25 5 Stability Tests for Panel Systems Products
5.1 Force Stability Test
27 5.2 Impact Stability Test
29 5.3 Force Stability Test for Freestanding Screens
32 6 Mechanical Strength Test for Panel Systems Products
34 Figures
3 Loading Configurations for Extendible Elements ………………………………………………. 16,17 5 Stability Tests for Panel Systems Products ………………………………………………….. 22,24,26 6 Mechanical Strength Tests for Panel Systems Products ……………………………………. 28,29 7 Panel Glide Assembly Strength Test
35 7 Panel Glide Assembly Strength Test
36 8 Panel Component Static Load Tests
8.1 Primary Surface Concentrated Functional Load Test
41 8.2 Horizontal Surface Distributed Functional Load Tests
42 8.3 Primary Surface Concentrated Proof Load Tests
8.4 Horizontal Surface Distributed Proof Load Tests
44 8.5 Transaction Surface Torsional Load Test
46 8.6 Functional Load Test For Panel Mounted Storage Units – Static
47 8.7 Proof Load Test for Panel Mounted Storage Units – Static
49 9 Lock Tests – Static
9.1 Test for Extendible Element Locks
51 9.2 Force Test for Door Locks
53 10 Panel Mounted Component Cyclic Durability Tests
10.1 Top Load Ease Cycle Test (for Primary Surfaces)
55 10.2 Cycle Test for Extendible Elements
56 2 Cycles for Extendible Elements
57 10.3 Cycle Test for Low Height Drawers
59 10.4 Extendible Element Retention Impact and Durability Tests
61 10.5 Extendible Element Rebound Test
63 10.6 Locking Mechanism Cycle Test
65 10.7 Adjustable Keyboard Support and Input Device Support Cycle Tests
68 10.8 Work Surface Vertical Adjustment Test
72 11 Panel-mounted Storage Unit Door Tests
3 Door Test Applicability
73 11.2 Strength Test for Vertically Hinged Doors, Bi-fold Doors, and Vert. Receding
4 Door Height vs. Load
75 11.3 Hinge Override Test for Vertically Hinged Doors
76 11.4 Vertical Receding Doors Strength Test
78 11.5 Horizontal Receding Doors Strength Test
81 11.6 Wear and Fatigue Tests for Hinged, Horizontally Sliding, and Tambour Doors
82 5 Wear and Fatigue Tests for Doors
84 11.7 Wear and Fatigue Test for Vertical Receding Door
86 11.8 Wear and Fatigue Test for Horizontal Receding Door
89 11.9 Vertical or Horizontal Receding Door Out Stop Test, Cyclic Impact & Durability
91 11.10 Slam Closed Test for Vertically Hinged Doors
93 11.11 Drop Cycle Test for Horizontally Hinged and Horizontally Receding Doors
94 11.12 Slam Test for Doors which Free-Fall Open or Closed
95 11.13 Slam Open/Closed Test for Doors that Do Not Free-Fall
97 11.14 Door Latch Test
99 12 Disengagement Tests for Panel Mounted Components
12.1 Upward Force Static Disengagement Test for Panel Mounted Components
6 Panel Mounted Component Disengagement Forces
101 12.2 Upward Force Impact Disengagement Test for Panel Mounted Components
102 8 Panel Component Static Load Tests ………………………………………………….. 34,36-38,41,43 9 Tests for Unit Locks ………………………………………………………………………………………. 46,48 10 Panel Mounted Component Cyclic Durability Tests ……………. 50,52,56,58,60,62-64,65,67 11 Door Tests ………………………………………………………. 71-73,75,77,78,81,83,86,88,90,92,93 12 Disengagement Tests for Panel Mounted Components ……………………………………… 96,98 13 Pull Force Test
103 13 Pull Force Test
104 14 Wear and Fatigue Test for Vertically Hinged and Horizontally Sliding Access Doors
105 14 Wear and Fatigue Test for Vertically Hinged and Horizontally Sliding Access Doors
106 15 Slam Open and Closed Test for Sliding Access Doors
107 15 Slam Open and Closed Test for Sliding Access Doors
109 16 Slam Closed Test for Vertically Hinged Access Doors
111 17 Force Test for Access Door Lock
16 Slam Closed Test for Vertically Hinged Access Doors. ………………………………….. 106-108 17 Force Test for Access Door Lock
113 18 Glass Retention Test for Access Doors
114 18 Glass Retention Test for Access Doors
115 Informative Annex A: Acoustical Performance
117 Annex A Bibliography
118 Informative Annex B: Full-Height Relocatable Walls
119 Informative Annex C: Summary of Changes
BIFMA X5.6 2016 RA2021
$81.25