BS 6037-1:2017
$167.15
Planning, design, installation and use of permanently installed access equipment. Code of practice – Suspended access equipment
Published By | Publication Date | Number of Pages |
BSI | 2017 | 38 |
This part of BS 6037 gives recommendations for the planning, design, installation, use, examination, maintenance and testing of permanently installed suspended access equipment, including equipment installed on a building to facilitate continuing routine maintenance of the building. It is intended for use by those involved in specifying, designing, managing the use of, maintaining and examining permanently installed suspended access equipment.
This British Standard does not cover industrial rope access and work positioning techniques, recommendations for which are given in BS 7985 .
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | Foreword |
5 | Introduction 1 Scope 2 Normative references |
6 | 3 Terms and definitions |
7 | 4 Identifying hazards and taking preventative action |
8 | Table 1 — Hazards encountered when installing, maintaining and using suspended access equipment with recommended actions |
9 | 5 Planning and exchange of information |
12 | 6 Health and safety |
13 | Table 2 — Safe use of suspended access equipment 7 Attachment of the suspended access equipment to the building |
14 | 8 Track system |
15 | 9 Suspension and safety wire ropes 10 Protection against lightning 11 Restraint systems |
16 | 12 Electrical systems |
17 | 13 Marking |
18 | 14 Commissioning, verification and handover Table 3 — Safety requirements for all suspended access equipment |
19 | 15 Responsibilities of the duty holder |
20 | 16 Operating instructions |
22 | 17 Instructions for use |
25 | 18 Provision of notices 19 Training and instruction |
26 | 20 Inspection, maintenance, testing and thorough examinations |
30 | 21 Record keeping |
31 | 22 Changes to the suspended access equipment |
32 | Annex A (informative) CE marking and declaration of conformity Annex B (normative) Control of hazards from electromagnetic fields (EMFs) |
33 | Annex C (informative) Suspended access equipment breakdown/rescue |
34 | Figure C.1 — Suspended access equipment breakdown/rescue flowchart |
35 | Annex D (normative) Training and retraining recommendations Annex E (informative) Useful addresses and contact information Table E.1 — Useful addresses and contact information |
37 | Bibliography |