This part of BS 6262 gives information and recommendations for vertical glazing in the external walls and interiors of buildings, with respect to:

  1. structural sealant glazing;

  2. bolt fixed structural glazing;

  3. frameless doors and entrances;

  4. mirrors.

  5. Bolt fixed structural glazing with countersunk holes is not specifically covered.

NOTE some guidance is also given on non-vertical use of mirrors.

These recommendations do not apply to:

  1. patent glazing (see BS 5516-1);

  2. glass in non-vertical applications (see BS 5516-2);

  3. glazing for furniture and fittings (see BS 7376 and BS 7449);

  4. glazing for commercial greenhouses (see BS 5502-21);

  5. glazing for domestic greenhouses.

Requirements for standards of workmanship for the application of sealants have been published separately as BS 8000-16, and therefore this subject is not dealt with in this standard.

PDF Catalog

PDF Pages PDF Title
1 BRITISH STANDARD
2 Committees responsible for this British Standard
3 Contents
5 1 Scope
2 Normative references
3 Terms and definitions
glazing (noun)
glazing (verb)
insulating glass unit
pane
6 plastics glazing sheet material
sealant bite
vertical glazing
four edge bonded structural sealant glazing
two edge bonded structural sealant glazing
Definition of sealant bite in structural sealant glazing
4 Structural sealant glazing
4.1 General
7 4.2 Design principles
8 Principles of a structural sealant glazing system
4.3 Compatibility of materials
9 4.4 Assembly
5 Glazing using structural glass fins
5.1 General
5.2 Design
5.3 Performance of glass with fin supports
10 Fin thickness
11 Determination of annealed float glass fin width to resist the design wind load
12 5.4 Fixing
6 Suspended glazing with annealed glass
13 Fin support box
7 Bolt fixed structural glazing
7.1 General
14 Principles of a toughened glass infill panel bolted connection
15 Relationship between bolt size, spreader plates and glass thickness
7.2 Bolt fixing of glass in barriers
16 Typical localized fixing clamp for free standing glass barrier
17 Typical continuous fixing clamp for free standing glass barrier
7.3 Frameless doors and door assemblies
Recommended frameless toughened door thicknesses
18 Principles of a cantilever fin support
19 Spacing of bolts in cantilevered fin support systems
7.4 Toughened glass suspended assemblies
8 Mirrors
8.1 General
20 8.2 Safety
8.3 Glass mirrors
21 8.4 Plastics mirrors
22 (informative) Simplified calculation of sealant dimensions for structural sealant glazing
(informative) Simplified calculation of sealant dimensions for structural sealant glazing
General
Structural sealant dimensions
Symbols
Limitations of the method
23 Calculation