BS 7870-4.12:2001

$142.49

LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV – Single core 11 kV copper foil sheath cables – Section 4.12: single core 11 kV copper foil sheath cables

Published By Publication Date Number of Pages
BSI 2001 26
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
1 BRITISH STANDARD
2 Committees responsible for this British�Standard
3 Contents
5 1 Scope
2 Normative references
3 Voltage designation
6 4 Construction and dimensions
4.1 Conductors
4.2 Screens and insulation
4.3 Water blocking tape
4.4 Copper foil sheath
7 4.5 Oversheath
4.6 Triplex cables
4.7 Marking
8 4.8 End sealing
4.9 Dimensions
Table 1
5 Tests
9 Table 2
10 6 Routine tests
6.1 Spark test
6.2 Conductor resistance
6.3 Copper foil sheath resistance
Table 3
6.4 Voltage test
6.5 Partial discharge test
6.6 Cable markings
7 Sample tests
7.1 Conductor material and construction
7.2 Conductor screen
7.3 Insulation
11 7.4 Circularity of insulated core
7.5 Insulation screen
7.6 Irregularities of insulation and screen
7.7 Water blocking tape
7.8 Copper foil sheath
7.9 Oversheath
7.10 Bending test/4�h voltage test
12 8 Type tests
8.1 Material tests
Table 4
13 Table 5
14 Table 6
8.2 Sequential electrical tests
15 Table 7
Table 8
8.3 Long term test
8.4 Short-circuit test
8.5 Earth fault spiking test
16 Annex A (informative)
Guidance on selection of single core copper foil sheath cables
Table A.1 Information to be specified by the user
17 Annex B (informative)
Guidance on type tests
General
Type tests on cables
Compatibility test
Type tests on components
Annex C (informative)
Water penetration test
Test piece
Test
18 Figure 1 Water penetration test
19 Annex D (informative)
Peel strength of copper foil overlap
Figure D.1 Peel strength of copper foil overlap
20 Annex E (informative)
Sidewall pressure test
Figure E.1 Sidewall pressure test
Table E.1 Sidewall pressure
21 Annex F (normative)
Impact test
Figure F.1 Impact test
22 Annex G (normative)
Earth fault spiking test
Objective
Spiking test sample
Electrical circuit
Spiking procedure
Test procedure
23 Number of samples/tests
Examination
BS 7870-4.12:2001