BS EN 12098-1:2013

$167.15

Controls for heating systems – Control equipment for hot water heating systems

Published By Publication Date Number of Pages
BSI 2013 36
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

This European Standard applies to electronic control equipment for heating systems with water as the heating medium and a flow water temperature up to 120 Ā°C.

This control equipment controls and regulates the distribution and/or the generation of heat in relation to the outside temperature and time and other reference variables.

This standard covers also controllers which contain an integrated optimum start or an optimum start-stop control function.

Safety requirements on heating systems remain unaffected by this standard. The dynamic behaviour of the valves and actuators are not covered in this standard.

A multi-distribution and/or multi-generation system needs a coordinated solution to prevent undesired interaction and is not part of this standard.

PDF Catalog

PDF Pages PDF Title
4 Contents Page
6 Foreword
7 Introduction
8 1 Scope
2 Normative references
3 Terms and definitions
14 4 Functionality
4.1 Functional objective
15 4.2 Control equipment functionality
5 Graphical symbols
6 Requirements
6.1 Data protection
6.2 Characteristic heating curve
16 6.3 Input signal ā€“ Sensors
17 6.4 Controller operation modes
6.4.1 General
6.4.2 Comfort operation mode
6.4.3 Economy operation mode
18 6.4.4 Building protection operation mode
6.4.5 Automatic operation mode
6.5 Frost protection
6.6 Additional functions
6.6.1 General
6.6.2 Summer/Winter switch function
6.6.3 Set back function
6.6.4 Optimum start function
6.6.5 Optimum stop function
19 6.7 Switching times
6.8 Manual Emergency Operation Mode (MEOM)
6.9 Parameter settings
6.10 Factory settings / Default values
6.10.1 Characteristic heating curve
20 6.10.2 Switching times / Operating condition
6.11 Switching relays
6.12 Electrical requirements
6.12.1 Electrical connections
6.12.2 Supply voltage
6.12.3 Electrical safety
6.12.4 Electro magnetic compatibility
6.13 Degree of protection
6.14 Environmentally induced stress due to temperature
21 6.15 Materials
6.16 Use of graphical symbols
7 Test methods
7.1 Data protection
7.2 Controller operation modes
7.3 Controller characteristic heating curve
26 7.4 Frost protection
7.5 Switching times
7.6 Manual Emergency Operation Mode
7.7 Optimum start-stop function
7.7.1 General
28 7.7.2 Test conditions
7.7.3 Test run
29 7.7.4 Test results start optimisation
31 7.7.5 Test results stop optimisation
7.7.6 Summer/Winter-switch
7.8 Set back
7.9 Parameter settings
7.10 Factory settings
7.11 Switching relays
7.12 Electrical test
32 7.13 Degrees of protection
7.14 Environmental individual stress due to temperature
8 Marking
9 Documentation
9.1 Technical documents
9.2 Technical specifications
9.2.1 Controller
33 9.2.2 Output signals
9.2.3 Input signals (Sensors)
9.3 Instruction installation
9.4 User guideline
34 Bibliography