BS EN 13203-2:2018
$167.15
Gas-fired domestic appliances producing hot water – Assessment of energy consumption
Published By | Publication Date | Number of Pages |
BSI | 2018 | 44 |
This document is applicable to gas-fired appliances producing domestic hot water. It applies to both instantaneous and storage tank appliances; waters-heaters and combination boilers that have: – a heat input not exceeding 400 kW; and – a hot water storage tank capacity (if any) not exceeding 2000 l. In the case of combination boilers, with or without storage tank, domestic hot water production is integrated or coupled, the whole being marketed as a single unit. EN 13203-1 sets out in qualitative and quantitative terms the performance in delivery of domestic hot water for a selected variety of uses. It also gives a system for presenting the information to the user. The present document sets out a method for assessing the energy performance of the appliances. It defines a number of daily load profiles for each domestic hot water use, kitchen, shower, bath and a combination of these, together with corresponding test procedures, enabling the energy performances of different gas-fired appliances to be compared and matched to the needs of the user. Where other technologies are combined with a gas-fired boiler or a water heater to produce domestic hot water, specific parts of EN 13203 apply.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
8 | 1 Scope 2 Normative references 3 Terms and definitions |
10 | 4 General test conditions 4.1 Reference conditions 4.2 Measurement uncertainties 4.2.1 General |
11 | 4.2.2 Steady state conditions 4.3 Test conditions 4.3.1 General 4.3.2 Test room 4.3.3 Water supply |
12 | 4.3.4 Initial adjustment of the appliance 4.3.5 Conditions for the determination of the maximum load profile 4.3.6 Electrical supply |
13 | 5 Determination of the energy consumption of the appliance 5.1 General 5.2 Load profiles |
20 | 5.3 Determination of the energy recovered by the useful water |
21 | 5.4 Calculation of gas energy 5.4.1 Calculation of daily gas energy consumption in summer mode 5.4.2 Calculation of daily gas energy consumption in winter mode |
22 | 5.4.3 Daily gas energy consumption seasonally weighted 5.5 Calculation of daily electrical energy consumption |
23 | 5.6 Measurement of energy consumption in standby mode 5.6.1 General 5.6.2 Calculation of daily gas energy consumption in standby mode |
24 | 5.6.3 Calculation of daily auxiliary electrical energy consumption in standby mode 5.7 Determination of daily auxiliary electrical energy consumption in off mode 6 Determination of the ratio of wasted water to total water |
25 | 7 Eco design Related Products Data 7.1 Water heating energy efficiency |
26 | 7.2 Annual fuel consumption (AFC) |
27 | 7.3 Annual electricity consumption (AEC) 7.4 Mixed water at 40°C (V40) for storage water heaters |
30 | Annex A (informative) Test conditions |
33 | Annex B (informative) Test rig and measurement devices B.1 General |
34 | B.2 Pressure measurement B.3 Temperature measurement |
38 | Annex C (informative)Declaration of the Maximum Load Profile |
39 | Annex ZA (informative)Relationship between this European Standard and the ecodesign requirements of Commission Regulation (EU) n° 814/2013 [OJEU L239 of 6 September 2013] aimed to be covered |
40 | Annex ZB (informative)Relationship between this European Standard and the energy labelling requirements of Commission Delegated Regulation (EU) No 812/2013 [OJEU L239 of 6 September 2013] aimed to be covered |
41 | Annex ZC (informative)Relationship between this European Standard and the ecodesign requirements of Commission Regulation (EU) n° 813/2013 [OJEU L239 of 6 September 2013] aimed to be covered |
42 | Annex ZD (informative)Relationship between this European Standard and the energy labelling requirements of Commission Delegated Regulation (EU) No 811/2013 [OJEU L239 of 6 September 2013] aimed to be covered |