This document specifies design requirements for non-powered access installed on cranes.
For other type of access, a requirement for information to be supplied is specified.
Slidable, retractable means of access are excluded from the scope, except movable hoop guards.
This document covers means of access to control stations and all access required for maintenance, certain erection and dismantling operations.
For those cranes which are intended to be erected and dismantled frequently to change their places of work, specific requirements for the access needed during these operations are not covered by this document and should be given in the appropriate European Standards for specific crane types.
Lighting of means of access is not covered by this document and should be given in the appropriate European Standards for specific crane types.
Specific requirements for access on particular types of cranes are given in the appropriate European Standard for the particular crane type.
The requirements given in this document do not take into account the safety distances related to:
-
guarding against hazard from moving parts;
-
relative movement between crane and adjacent structure or the ground/floor;
-
hazardous surface temperature;
-
electrical equipment.
The significant hazards covered by this document are identified in Clause 4.
This document is not applicable to cranes which are manufactured before the date of publication by CEN of this standard.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
7 | 1 Scope 2 Normative references |
8 | 3 Terms and definitions 4 List of significant hazards |
9 | 5 Safety requirements and protective measures 5.1 Selection of means of access |
10 | 5.2 Classification of access |
11 | 5.3 General design principles |
12 | 5.4 Stairs and step ladders |
13 | 5.5 Spiral stairs |
14 | 5.6 Rung ladders – footholds 5.6.1 Rung ladders |
16 | 5.6.2 Footholds |
17 | 5.7 Hoop guards 5.7.1 General |
18 | 5.7.2 Movable hoop-guards |
19 | 5.8 Walkways, inclined walkways, platforms |
20 | 5.9 Minimum clear passage of access routes |
21 | 5.10 Handrails and side protection |
23 | 5.11 Handholds |
24 | 5.12 Hatches and manholes |
25 | 5.13 Strength, means of access and their supporting structures 6 Verification of the safety requirements and/or protective measures |
26 | 7 Information for use |
27 | Annex A (informative)Selection of a suitable set of crane standards for a given application |
29 | Annex B (informative)Examples of surfaces considered to be slip-resistant |
31 | Annex ZA (informative)Relationship between this European standard and the essential requirements of Directive 2006/42/EC aimed to be covered |