BS EN 13639:2017
$142.49
Determination of total organic carbon in limestone
Published By | Publication Date | Number of Pages |
BSI | 2017 | 30 |
This European Standard specifies methods for the determination of the total organic carbon content (TOC) in limestone. The standard describes the reference method and alternative methods which can be considered to be equivalent. In the case of a dispute, only the reference method is used. Any other methods may be used provided they are calibrated, either against the reference method or against internationally accepted reference materials, in order to demonstrate their equivalence.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
7 | 1 Scope 2 Normative references 3 General requirements for testing 3.1 Number of tests 3.2 General statistical terms |
8 | 3.3 Expression of masses and results 3.4 Blank determinations 3.5 Sampling and sampling preparation 3.6 General test principles |
9 | 4 Reagents |
11 | 5 General apparatus 5.1 Balances 5.2 Laboratory ovens |
12 | 5.3 Crucibles 6 Gravimetric method with wet oxidation (reference method) 6.1 Principle 6.2 Apparatus |
13 | 6.3 Procedure |
14 | 6.4 Calculation 7 Gravimetric method with furnace oxidation (alternative method No. 1) 7.1 Principle 7.2 Apparatus |
16 | 7.3 Procedure 7.3.1 Filling the quartz tube 7.3.2 Preparing an absorption tube 7.3.3 Determination 7.4 Calculation |
17 | 8 Infrared detection method with furnace oxidation (low temperature) (alternative method No. 2) 8.1 Principle 8.2 Apparatus |
19 | 8.3 Procedure 8.3.1 Filling the quartz tube 8.3.2 Filling the absorption tower 8.3.3 Filling the adsorption tower 8.3.4 Adjustments 8.3.5 Cleaning |
20 | 8.3.6 Calibration 8.3.7 Validation 8.3.8 Determination 8.4 Calculation |
21 | 9 Infrared detection or conductivity methods with furnace oxidation (high temperature): procedure A (alternative method No. 3) 9.1 Principle 9.2 Apparatus |
22 | 9.3 Procedure 9.3.1 Calibration 9.3.2 Determination 9.3.3 Expression of results |
23 | 10 Infrared detection or conductivity methods with furnace oxidation (high temperature): procedure B (alternative method No. 4) 10.1 Principle 10.2 Apparatus 10.3 Procedure 10.3.1 Calibration 10.3.2 Determination 10.3.3 Expression of results |
24 | 11 Repeatability and reproducibility standard deviation, determination limit 12 Test report |
25 | Annex A (informative)Features of commercial HF (High Frequency) combustion/infrared carbon analyzers A.1 Combustion |
26 | A.2 Infrared gas analyser |
27 | Annex B (informative)Assignment of reagents to methods |