BS EN 14150:2019 – TC:2020 Edition
$134.27
Tracked Changes. Geosynthetic barriers. Determination of permeability to liquids
Published By | Publication Date | Number of Pages |
BSI | 2020 | 42 |
This document specifies a method for measuring the steady-state liquid flow through a geosynthetic barrier, used to contain liquids in long-term applications. The test method and described apparatus allow the measurement of flows accurately down to 10?6 m³/m²/day. In particular circumstances where testing indicates that values obtained for a geosynthetic barrier lie below the threshold of sensitivity of this test method, then the value of liquid flow is declared as being less than10?6 m³/m²/day. Due to its long duration, this test method is not suitable for production control testing. Clay geosynthetic barriers cannot be tested with this apparatus.
PDF Catalog
PDF Pages | PDF Title |
---|---|
26 | undefined |
30 | 1 Scope 2 Normative references 3 Terms and definitions 4 Principle 5 Apparatus 5.1 Cell |
31 | 5.2 Volume measuring devices and pressure delivery system |
33 | 5.3 Liquid supply 5.4 Temperature control |
34 | 6 Specimens 7 Procedure 7.1 General 7.2 Installation 7.2.1 General 7.2.2 Type A volume measuring devices: |
35 | 7.2.3 Type B volume measuring devices: 7.3 Test stage |
36 | 8 Results 9 Test validity |
37 | 10 Test report |
38 | Annex A (normative)Description of post-control stages A.1 General A.2 First post-control stage A.3 Second post-control stage A.4 Calculations |
39 | A.5 Volume-temperature dependence coefficients A.6 Test |