Shopping Cart

No products in the cart.

BS EN 15254-5:2018

$142.49

Extended application of results from fire resistance tests. Non-loadbearing walls – Metal sandwich panel construction

Published By Publication Date Number of Pages
BSI 2018 26
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document defines rules for extended applications, provides guidance, and, where appropriate, defines procedures, for variations of certain parameters and factors associated with the design of internal and external non-loadbearing walls constructed of metal sandwich panels and that have been tested in accordance with EN 1364-1, which could generate a classification in accordance with EN 13501-2. EN 15254-5 applies for self-supporting, double skin metal faced sandwich panels having an insulating core bonded to both facings as defined in EN 14509.

PDF Catalog

PDF Pages PDF Title
2 undefined
6 1 Scope
2 Normative references
3 Terms and definitions, symbols and abbreviations
3.1 Terms and definitions
8 3.2 Symbols and abbreviations
9 4 Establishing the field of extended application
4.1 General
4.2 Assumptions in the extended application
10 5 Rules for extended applications of the tested product/construction
5.1 General
12 5.2 Variations in the materials of the product
5.2.1 General
5.2.2 Variations in the metal sheets
5.2.2.1 Variations in the coatings
5.2.2.2 Variations in the metal material
5.2.2.3 Changes in profile geometry of facing
13 5.2.3 Variations in the adhesive
5.2.4 Variations in the core material
5.2.4.1 General
5.2.4.2 Mineral wool (MW)
14 5.2.4.3 Polyurethane (PUR) and polyisocyanurate (PIR)
5.2.4.4 Extruded polystyrene (XPS) and expanded polystyrene (EPS)
5.2.4.5 Phenolic foam (PF)
5.2.4.6 Cellular glass (CG)
5.3 Variations in the construction
5.3.1 Variations in span length
16 5.3.2 Variations in orientation
5.3.3 Variations in the panel thickness
17 5.3.4 Variations in the longitudinal joint construction
5.3.5 Variations in the boundary conditions and fixing system
5.3.6 Length and height of wall construction
5.4 Interaction between the factor influences
5.5 Support structure
18 5.6 Heating conditions
6 Calculation methods and additional measurements
6.1 Calculation methods
6.1.1 General
6.1.2 Calculation of strength properties
6.2 Additional measurements to be carried out in the reference test
19 7 Report of the extended application analysis
20 Annex A (informative)Typical behaviour of a metal faced sandwich panel wall when exposed to fire
21 Annex B (normative)Evaluation of extension of span length
BS EN 15254-5:2018