BS EN 15287-1:2023 – TC

$280.87

Tracked Changes. Chimneys. Design, installation and commissioning – Chimneys and connecting flue pipes for non-room sealed combustion appliances

Published By Publication Date Number of Pages
BSI 2023 364
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document describes the method of specifying the design, installation and labelling criteria for system chimneys, construction of custom-built chimneys, the relining of existing chimneys and connecting flue pipes for non-room sealed combustion appliances as well as the use of chimney products. It also gives information on commissioning of an installed chimney. This document applies to chimneys which are subject to the following limiting conditions: – the distance between the supports not to exceed 4 m; – the distance above the last structural attachment not to exceed 3 m; – the free-standing height above the uppermost structural support attachment for chimneys with rectangular cross section is not more than five times the smallest external dimension. The methods in this part of this document are applicable to chimneys and connecting flue pipes for non-room sealed combustion appliances. The methods in Part 2 of this document are applicable to chimneys and connecting flue pipes for room sealed combustion appliances.

PDF Catalog

PDF Pages PDF Title
1 30483915
216 A-30432872
217 undefined
224 1 Scope
2 Normative references
225 3 Terms and definitions
233 4 Design
4.1 General
4.2 Characteristics
4.2.1 Designation of an installed chimney
4.2.2 Temperature classes
234 4.2.3 Pressure classes
4.2.4 Condensate resistance classes
235 4.2.5 Corrosion resistance classes
4.2.6 Sootfire resistance classes
4.2.7 Minimum distance to combustible material
236 4.3 Required information
4.3.1 Sources of data and information
4.3.2 Local conditions
4.3.3 Combustion appliance information
4.3.4 Combustion air supply
4.3.5 Building structure and chimney route
237 4.3.6 Existing chimney
4.3.7 Chimney product specification
4.4 Design requirements
4.4.1 General
4.4.2 Route of the chimney and the connecting flue pipe
4.4.2.1 Location of chimney outlet
238 4.4.2.2 Chimney route
4.4.2.3 Connecting flue pipe route
239 4.4.3 Designation classes
4.4.3.1 General
4.4.3.2 System chimney
4.4.3.3 Custom-built and relined chimney
240 4.4.3.4 Connecting flue pipe
4.4.4 Materials of construction
4.4.4.1 System chimneys
4.4.4.2 Custom-built and relined chimneys
241 4.4.4.3 Connecting flue pipe and adapters
4.4.4.4 Supplementary components or additional materials
4.4.5 Chimney sizing and characteristics
4.4.6 Installation requirements
4.4.6.1 Fire resistance external to external
4.4.6.2 Minimum distance to combustible material (resistance to fire – internal to external)
242 4.4.6.3 Accidental human contact
4.4.6.4 Accidental ignition of extraneous material
4.4.6.5 Supports
243 4.4.6.6 Joints
4.4.6.7 Condensate drainage and rainwater disposal
4.4.6.8 Positive pressure chimneys
244 4.4.6.9 Chimney offsets
4.4.6.10 Access for inspection, cleaning and measuring
4.4.6.11 Minimum distance between openings in the chimney
4.4.6.12 Back ventilation
245 4.4.6.13 External parts
4.4.6.14 Weatherproofing
246 4.4.6.15 Lightning protection
4.4.6.16 Earthing of chimneys
4.4.7 Accessories
4.4.7.1 General
4.4.7.2 Draught regulator, standstill opening device and combined secondary air device
247 4.4.7.3 Explosion relief
4.4.7.4 Silencer
4.4.7.5 Rain cap
4.4.7.6 Flue damper
248 4.4.7.7 Chimney fans
4.4.7.8 Terminals
249 4.4.7.9 Particulate matter filters or separators
4.5 Chimney plate and additional information
250 5 Installation
5.1 General
5.2 Construction of relined chimneys
5.3 Chimney plate
251 6 Commissioning/handover
252 Annex A (informative)Terminology
255 Annex B (informative)List of combustion appliance data required for the design of a chimney
B.1 For choosing the chimney type (required chimney designation)
B.2 For calculation of the chimney (sizing, see 4.4.5)
B.3 For combustion appliance/connecting flue pipe/chimney adapter design/choice
256 Annex C (informative)Example of typical building structure designed to assist exchange of information
259 Annex D (informative)Location of chimney outlets
263 Annex E (informative)Correlation between the product designation of metal system chimneys, liners and connecting flue pipes and the corrosion loads in Member States (MS)
270 Annex F (informative)Correlation between type of flue liner according to the designation of parameters for clay/ceramic flue liners, clay/ceramic flue blocks and concrete flue blocks and the designation according to EN 1443
272 Annex G (informative)Example for chimney plates
273 Annex H (informative)Determination of the chimney designation for custom-built and relined chimneys
H.1 General
H.2 Temperature class
281 H.3 Pressure class
282 H.4 Condensate resistance class
H.5 Corrosion resistance class
H.6 Sootfire resistance class
283 H.7 Minimum distance to combustible material
284 Annex I (informative)Example for the determination of the designation of a relined chimney using a metal flue liner
I.1 Input data for a typical relined chimney
I.1.1 Existing chimney
I.1.2 Flue liner
I.1.3 Insulation
285 I.2 Temperature class
I.2.1 General
I.2.2 Material characteristic
I.2.3 Resistance to fire – internal to external
286 I.2.4 Human contact
I.2.5 Determination of temperature class
I.2.6 Check of mean temperatures
287 I.3 Pressure class
I.4 Condensate resistance class
I.5 Corrosion resistance class
I.6 Sootfire resistance class
I.7 Minimum distance to combustible material
288 I.8 Designation of the relined chimney
I.9 Chimney plate of the relined chimney in this example
289 Annex J (informative)Example for the determination of the designation of a custom-built chimney using a clay/ceramic flue liner
J.1 Input data for a custom-built chimney
J.1.1 General
J.1.2 Flue liner
J.1.3 Insulation
J.1.4 Enclosure
J.2 Temperature class
J.2.1 General
290 J.2.2 Material characteristic
J.2.3 Resistance to fire – internal to external
291 J.2.4 Human contact
J.2.5 Determination of temperature class
J.2.6 Check of the temperature at the outer surface of the chimney
J.3 Pressure class
J.4 Condensate resistance class
J.5 Corrosion resistance class
292 J.6 Sootfire resistance class
J.7 Minimum distance to combustible material
J.8 Designation of the custom-built chimney
J.9 Chimney plate for the custom-built chimney in this example
293 Annex K (informative)Minimum distances to combustible material
K.1 Connecting flue pipes without designation according to 4.2
K.2 Access components
294 K.3 Plastic flue liners in a chimney stack
296 Annex L (informative)Calculating the temperature of adjacent material
L.1 Example for calculation of the temperature of adjacent material (e.g. weatherproofing)
297 L.2 Example for calculation of the temperature of adjacent materials (e.g. weatherproofing)
299 Annex M (informative)Useful hints for handling of materials and components on site
M.1 General
M.2 Check of existing chimney
M.3 Checking before installation
M.4 Checking on delivery of materials
M.5 Site handling and storage
300 M.6 Coordination of work
301 Annex N (informative)Chimney commissioning
N.1 General
N.2 Physical checks
302 N.3 Operational checks
N.3.1 General
N.3.2 Tightness of the chimney
N.3.2.1 Flue flow test for gas
N.3.2.2 Flue flow test for oil
303 N.3.2.3 Flue flow test for solid fuel
N.3.2.4 Pressure test for positive pressure chimneys
304 N.3.3 Function of the combustion appliance (Flue draught test)
305 Annex O (informative)Recommendations for inspection, cleaning and maintenance
O.1 General
O.2 Inspection and cleaning
O.3 Maintenance
306 Annex P (informative)Flue damper
P.1 General
307 P.2 Flue damper types
P.2.1 Type 1
308 P.2.2 Type 2
P.2.3 Type 3
P.2.4 Type 4
309 P.2.5 Type 5
P.3 Additional information for the use of a flue damper type 2 and 4
P.3.1 Combustion appliances with forced draught burners
310 P.3.2 Combustion appliances with burners with fan without air purging
P.3.3 Combustion appliances with burners with fan with post-purge period
P.3.4 Combustion appliances with gas burners without fan
P.3.5 Closing time of the flue damper flap
P.3.6 Malfunction of the flue damper
311 Annex Q (informative)Terminals
Q.1 Terminal types
Q.2 Required information
BS EN 15287-1:2023 - TC
$280.87