BS EN 15501:2013
$189.07
Thermal insulation products for building equipment and industrial installations. Factory made expanded perlite (EP) and exfoliated vermiculite (EV) products. Specification
Published By | Publication Date | Number of Pages |
BSI | 2013 | 46 |
This European Standard specifies the requirements for factory made expanded perlite and exfoliated vermiculite products which are used for the thermal insulation of building equipment and industrial installations with an operating temperature in the range of approximately 0 °C to + 1 100 °C.
Expanded perlite and exfoliated vermiculite products can be used below 0 °C but special tests regarding the suitability of the product in the intended application are advised (e.g. liquefaction of oxygen). Manufacturer’s advice should be heeded in all cases.
The products are manufactured in the form of boards, pipe sections, segments, prefabricated ware and special ware.
This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
Products covered by this European Standard are also used in prefabricated thermal insulation systems and composite panels; the structural performance of systems incorporating these products is not covered.
This European Standard does not specify the required level of a given property that is achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application can be found in regulations and invitations to tender.
Products with a declared thermal conductivity greater than 0,6 W/(mK) at 10 °C are not covered by this European Standard.
This European Standard does not cover products intended to be used for the insulation of the building structure.
The European Standard does not cover the following acoustical aspects: direct airborne sound insulation and impact transmission noise index.
PDF Catalog
PDF Pages | PDF Title |
---|---|
9 | 1 Scope 2 Normative references |
10 | 3 Terms, definitions, symbols, units and abbreviated terms 3.1 Terms and definitions 3.1.1 Terms and definitions as given in EN ISO 9229:2007 |
11 | 3.1.2 Additional terms and definitions |
12 | 3.2 Symbols, units and abbreviated terms 3.2.1 Symbols and units |
13 | 3.2.2 Abbreviated terms 4 Requirements 4.1 General |
14 | 4.2 For all applications 4.2.1 Thermal conductivity 4.2.2 Dimensions and tolerances 4.2.2.1 Linear dimensions 4.2.2.2 Squareness |
15 | 4.2.2.3 Flatness 4.2.2.4 Pipe section linearity 4.2.3 Dimensional stability 4.2.4 Reaction to fire 4.2.5 Durability characteristics 4.2.5.1 General 4.2.5.2 Durability of reaction to fire against ageing/degradation and high temperature |
16 | 4.2.5.3 Durability of thermal resistance against ageing/degradation 4.2.5.4 Durability of thermal resistance against high temperature 4.3 For specific applications 4.3.1 General 4.3.2 Maximum service temperature 4.3.3 Minimum service temperature |
17 | 4.3.4 Compressive stress or compressive strength 4.3.5 Trace quantities of water soluble ions and the pH value 4.3.6 Water vapour diffusion resistance 4.3.7 Short term water absorption by partial immersion 4.3.8 Dangerous substances |
18 | 4.3.9 Continuous glowing combustion 5 Test methods 5.1 Sampling 5.2 Conditioning 5.3 Testing 5.3.1 General |
20 | 5.3.2 Thermal conductivity |
21 | 5.3.3 Maximum service temperature 5.3.3.1 General 5.3.3.2 Test specimens 5.3.4 Reaction to fire 6 Designation code |
22 | 7 Evaluation of conformity 7.1 General 7.2 Initial Type Testing 7.3 Factory Production Control 8 Marking and labelling |
23 | Annex A (normative) Factory production control |
27 | Annex B (normative) Special conditions for the determination of organic content B.1 Principle B.2 Apparatus B.3 Procedure B.4 Calculation and expression of results |
28 | B.5 Test report |
29 | Annex C (informative) Preparation of the test specimens to measure thermal conductivity C.1 Preparation of the test specimens to measure thermal conductivity C.2 Ageing |
30 | Annex D (informative) Product specific details for mounting and fixing for reaction to fire testing |
34 | Annex E (informative) Additional properties E.1 General E.2 Coefficient of thermal expansion E.3 Apparent and true porosity E.4 Air flow resistance E.5 Creep in compression E.6 Permeability to gases E.7 Bending strength E.8 Apparent density |
36 | Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Directive ZA.1 Scope and relevant characteristics |
38 | ZA.2 Procedures for attestation of conformity of factory made expanded perlite and exfoliated vermiculite products ZA.2.1 Systems of attestation of conformity |
40 | ZA.2.2 EC certificate and declaration of conformity |
41 | ZA.3 CE Marking and labelling |