Thermal insulation products for building equipment and industrial installations. Factory made expanded perlite (EP) and exfoliated vermiculite (EV) products. Specification

Published By Publication Date Number of Pages
BSI 2013 46
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This European Standard specifies the requirements for factory made expanded perlite and exfoliated vermiculite products which are used for the thermal insulation of building equipment and industrial installations with an operating temperature in the range of approximately 0 °C to + 1 100 °C.

Expanded perlite and exfoliated vermiculite products can be used below 0 °C but special tests regarding the suitability of the product in the intended application are advised (e.g. liquefaction of oxygen). Manufacturer’s advice should be heeded in all cases.

The products are manufactured in the form of boards, pipe sections, segments, prefabricated ware and special ware.

This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.

Products covered by this European Standard are also used in prefabricated thermal insulation systems and composite panels; the structural performance of systems incorporating these products is not covered.

This European Standard does not specify the required level of a given property that is achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application can be found in regulations and invitations to tender.

Products with a declared thermal conductivity greater than 0,6 W/(mK) at 10 °C are not covered by this European Standard.

This European Standard does not cover products intended to be used for the insulation of the building structure.

The European Standard does not cover the following acoustical aspects: direct airborne sound insulation and impact transmission noise index.

PDF Catalog

PDF Pages PDF Title
9 1 Scope
2 Normative references
10 3 Terms, definitions, symbols, units and abbreviated terms
3.1 Terms and definitions
3.1.1 Terms and definitions as given in EN ISO 9229:2007
11 3.1.2 Additional terms and definitions
12 3.2 Symbols, units and abbreviated terms
3.2.1 Symbols and units
13 3.2.2 Abbreviated terms
4 Requirements
4.1 General
14 4.2 For all applications
4.2.1 Thermal conductivity
4.2.2 Dimensions and tolerances
4.2.2.1 Linear dimensions
4.2.2.2 Squareness
15 4.2.2.3 Flatness
4.2.2.4 Pipe section linearity
4.2.3 Dimensional stability
4.2.4 Reaction to fire
4.2.5 Durability characteristics
4.2.5.1 General
4.2.5.2 Durability of reaction to fire against ageing/degradation and high temperature
16 4.2.5.3 Durability of thermal resistance against ageing/degradation
4.2.5.4 Durability of thermal resistance against high temperature
4.3 For specific applications
4.3.1 General
4.3.2 Maximum service temperature
4.3.3 Minimum service temperature
17 4.3.4 Compressive stress or compressive strength
4.3.5 Trace quantities of water soluble ions and the pH value
4.3.6 Water vapour diffusion resistance
4.3.7 Short term water absorption by partial immersion
4.3.8 Dangerous substances
18 4.3.9 Continuous glowing combustion
5 Test methods
5.1 Sampling
5.2 Conditioning
5.3 Testing
5.3.1 General
20 5.3.2 Thermal conductivity
21 5.3.3 Maximum service temperature
5.3.3.1 General
5.3.3.2 Test specimens
5.3.4 Reaction to fire
6 Designation code
22 7 Evaluation of conformity
7.1 General
7.2 Initial Type Testing
7.3 Factory Production Control
8 Marking and labelling
23 Annex A (normative) Factory production control
27 Annex B (normative) Special conditions for the determination of organic content
B.1 Principle
B.2 Apparatus
B.3 Procedure
B.4 Calculation and expression of results
28 B.5 Test report
29 Annex C (informative) Preparation of the test specimens to measure thermal conductivity
C.1 Preparation of the test specimens to measure thermal conductivity
C.2 Ageing
30 Annex D (informative) Product specific details for mounting and fixing for reaction to fire testing
34 Annex E (informative) Additional properties
E.1 General
E.2 Coefficient of thermal expansion
E.3 Apparent and true porosity
E.4 Air flow resistance
E.5 Creep in compression
E.6 Permeability to gases
E.7 Bending strength
E.8 Apparent density
36 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Directive
ZA.1 Scope and relevant characteristics
38 ZA.2 Procedures for attestation of conformity of factory made expanded perlite and exfoliated vermiculite products
ZA.2.1 Systems of attestation of conformity
40 ZA.2.2 EC certificate and declaration of conformity
41 ZA.3 CE Marking and labelling