BS EN 15625:2021
$142.49
Railway applications. Braking. Automatic variable load sensing devices
Published By | Publication Date | Number of Pages |
BSI | 2021 | 30 |
This document applies to automatic variable load sensing devices designed to continuously sense the load of a railway vehicle and provide a pneumatic output signal that can be used by a relay valve for the automatic variation of the air pressure used for brake applications, thereby adjusting the brake force accordingly to achieve the required brake performance.
This document specifies the requirements for the design, testing and quality assurance of automatic variable load sensing devices.
The requirements of this document are not fully applicable for tests on vehicle level (vehicle homologation tests).
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
7 | 1 Scope 2 Normative references 3 Terms and definitions |
9 | 4 Symbols and abbreviations 5 Design and manufacture 5.1 General 5.2 Functional requirements 5.2.1 Operating requirements 5.2.2 Characteristics of weighing valves |
10 | 5.2.3 Mechanical requirements 5.2.4 Tightness 5.3 Fire behaviour |
11 | 5.4 Shock and vibration 5.5 Service life 5.6 Compressed air quality 5.7 Environmental conditions 5.7.1 General 5.7.2 Ambient temperature 5.7.3 Altitude |
12 | 5.7.4 Humidity 5.7.5 Rain 5.7.6 Snow, ice and hail 5.7.7 Solar radiation 5.7.8 Pollution |
13 | 5.8 External appearance 5.9 Design requirements regarding pressure stress 5.10 Pneumatic connections 6 Type tests 6.1 General |
14 | 6.2 Individual automatic variable load sensing device type tests 6.2.1 Test bench for individual automatic variable load sensing devices type tests |
15 | 6.2.2 Sampling for type test 6.2.3 Test requirements |
16 | 6.2.4 Check of physical and geometrical characteristics 6.2.4.1 Procedure 6.2.4.2 Pass/fail criteria 6.2.5 Tightness 6.2.5.1 General 6.2.5.2 Leakage for F = 0 kN |
17 | 6.2.5.3 Leakage for F = 10 kN 6.2.5.4 Leakage for F = 50 kN 6.2.6 Characteristic, hysteresis 6.2.6.1 Procedure |
18 | 6.2.6.2 Pass/fail criteria 6.2.7 Operation at extreme temperature 6.2.7.1 General |
19 | 6.2.7.2 Leakage for F = 0 kN 6.2.7.3 Leakage for F = 10 kN 6.2.7.4 Leakage for F = 50 kN 6.2.7.5 Characteristic and hysteresis at extreme temperatures |
20 | 6.2.8 Shock and vibration tests 6.2.8.1 Procedure |
21 | 6.2.8.2 Test sequence 6.2.8.3 Pass/fail criteria 7 In-service assessment 8 Designation 9 Identification and marking |
23 | Annex A (informative)Assessment of an automatic variable load sensing device when fitted to a vehicle A.1 General A.2 Design acceptance testing set up A.3 Running tests A.3.1 General A.3.2 Pneumatic automatic variable load sensing device – Air consumption A.3.2.1 Procedure A.3.2.2 Pass/fail criteria |
24 | A.3.3 Automatic variable load sensing device – Output signal variation A.3.3.1 Procedure A.3.3.2 Pass/fail criteria |
25 | Annex B (normative)In-service assessment |
26 | Annex ZA (informative)Relationship between this European Standard and the Essential Requirements of EU Directive 2016/797/EU aimed to be covered |