BS EN 15703-2:2014
$102.76
Copper and copper alloys. Determination of manganese content – Flame atomic absorption spectrometric method (FAAS)
Published By | Publication Date | Number of Pages |
BSI | 2014 | 18 |
This European Standard specifies a flame atomic absorption spectrometric method (FAAS) for the determination of the manganese content of copper and copper alloys in the form of unwrought, wrought and cast products.
The method is applicable to products having manganese mass fractions between 0,001 0 % and 6,0 %.
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | Contents Page |
5 | Foreword |
6 | 1 Scope 2 Normative references 3 Principle 4 Reagents 4.1 Hydrochloric acid, HCl (ρ = 1,19 g/ml) 4.2 Nitric acid, HNO3 (ρ = 1,40 g/ml) 4.3 Hydrofluoric acid, HF (ρ = 1,13 g/ml) 4.4 Nitric acid solution, 1 + 1 4.5 Lanthanum(III) chloride solution, 100 g/l 4.6 Sulphuric acid, H2SO4 (ρ = 1,84 g/ml) |
7 | 4.7 Sulphuric acid solution, 1 + 9 4.8 Manganese stock solution, 1,0 g/l Mn 4.8.1 Cleaning of manganese metal 4.8.2 Preparation of stock solution 4.9 Manganese standard solution, 0,10 g/l 4.10 Manganese standard solution, 0,010 g/l 4.11 Copper matrix solution, 20 g/l Cu 4.12 Copper matrix solution, 2 g/l Cu 5 Apparatus 5.1 Atomic absorption spectrometer, fitted with an air/acetylene burner |
8 | 5.2 Manganese hollow-cathode lamp 6 Sampling 7 Procedure 7.1 Preparation of the test portion solution 7.1.1 Test portion 7.1.2 Test portion solution 7.1.3 Manganese mass fractions between 0,001 % and 0,020 % 7.1.4 Manganese mass fractions between 0,020 % and 0,50 % 7.1.5 Manganese mass fractions between 0,50 % and 2,0 % 7.1.6 Manganese mass fractions between 2,0 % and 6,0 % |
9 | 7.2 Blank test 7.3 Check test 7.4 Establishment of the calibration curve 7.4.1 Preparation of the calibration solutions 7.4.1.1 General 7.4.1.2 Manganese mass fractions between 0,001 0 % and 0,020 % |
10 | 7.4.1.3 Manganese mass fractions between 0,020 % and 0,5 % 7.4.1.4 Manganese mass fractions between 0,5 % and 2,0 % |
11 | 7.4.1.5 Manganese mass fractions between 2,0 % and 6,0 % 7.4.2 Adjustment of the atomic absorption spectrometer |
12 | 7.4.3 Spectrometric measurement of the calibration solutions 7.4.4 Calibration curve 7.5 Determination 7.5.1 General 7.5.2 Preliminary spectrometric measurement 7.5.3 Spectrometric measurements 7.5.3.1 Use of the calibration curve 7.5.3.2 Use of bracketing method 8 Expression of results 8.1 Use of the calibration curve |
13 | 8.2 Use of the bracketing method |
14 | 9 Precision |
15 | 10 Test report |
16 | Bibliography |