BS EN 16147:2017

$198.66

Heat pumps with electrically driven compressors. Testing, performance rating and requirements for marking of domestic hot water units

Published By Publication Date Number of Pages
BSI 2017 56
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This European Standard specifies methods for testing, rating of performance and calculation of water heating energy efficiency of air/water, brine/water, water/water and direct exchange/water heat pump water heaters and heat pump combination heaters with electrically driven compressors and connected to or including a domestic hot water storage tank for domestic hot water production.

This European Standard comprises only the testing procedure for the domestic hot water production of the heat pump system.

NOTE 1

Testing procedures for simultaneous operation for domestic hot water production and space heating are not treated in this standard. Simultaneous means that domestic hot water production and space heating generation occur at the same time and may interact.

NOTE 2

For heat pump combination heaters the seasonal efficiency of space heating is determined according to EN 14825 .

This European Standard only applies to water heaters which are supplied in a package of heat pump and storage tank. In the case of water heaters consisting of several parts with refrigerant connections, this European Standard applies only to those designed and supplied as a complete package.

This European Standard does not specify requirements of the quality of the used water.

PDF Catalog

PDF Pages PDF Title
2 National foreword
8 1 Scope
2 Normative references
9 3 Terms and definitions
12 4 Symbols and abbreviations
14 5 Installation requirements
5.1 Test apparatus and uncertainties of measurement
15 5.2 Test room for the outdoor heat exchanger of air source heat pumps
16 5.3 Installation and connection of the heat pump
5.4 Installation of heat pumps consisting of several parts
6 Settings and test conditions
6.1 General
6.2 Settings for non-ducted air source units
17 6.3 Setting the external static pressure difference for ducted air source units
6.4 Setting the difference of temperature for heat pumps using a liquid as heat source
6.5 Test conditions
6.5.1 General test conditions
6.5.2 Additional test conditions
20 7 Performance tests
7.1 General
7.2 Basic principles
21 7.3 Off-peak products
7.4 Power input corrections
7.4.1 Power input of fans for heat pumps with duct connection
22 7.4.2 Power input of liquid pumps
23 7.5 Stabilization [stage A]
7.6 Filling and storage [stage B]
7.7 Filling and heating up period [stage C]
24 7.8 Standby power input [stage D]
7.9 Water draw-offs and COP calculation [stage E]
7.9.1 Determination of the useful energy
26 7.9.2 Determination of the electrical energy consumption (WEL-LP)
27 7.9.3 Coefficient of performance (COPDHW)
7.10 Reference hot water temperature and volume of mixed water at 40 °C [stage F]
28 7.11 Calculation of the smart control factor SCF
7.11.1 General
7.11.2 Smart Control Test procedure
7.11.2.1 Measurement procedure
29 7.11.2.2 Installation
7.11.2.3 Stabilization
30 7.11.2.4 Filling and heat-up
7.11.2.5 Stabilization before reference period
7.11.2.6 Reference period
31 7.11.2.7 Smart period
32 7.11.2.8 Reporting of “Smart Control Factor” (SCF)
7.11.2.9 Check cycle
7.12 Determination of the ambient correction term Qcor
33 7.13 Water heating energy efficiency ηwh
7.13.1 Determination of Qelec
7.13.2 Calculation of ηwh for heat pump water heaters and heat pump combination water heaters
7.13.3 Calculation of the Annual Consumption of electric energy
7.14 Other performance
7.14.1 Rated heat output
34 7.14.2 Seasonal coefficient of performance (SCOPDHW)
8 Other tests
8.1 Temperature operating range
35 8.2 Outside the operating range
8.3 Safety devices checking test
8.3.1 General
8.3.2 Shutting off the heat transfer medium flows
36 8.3.3 Complete power supply failure
8.4 Condensate draining
9 Test results and test report
9.1 Data to be recorded
38 9.2 Test report
9.2.1 General information
39 9.2.2 Main results
40 10 Marking
11 Documentation
11.1 Technical data sheet
11.1.1 General description
11.1.2 Performance characteristics
41 11.2 Instructions
11.2.1 General
11.2.2 Physical description
11.2.3 Additional heating devices, if integrated in unit
11.2.4 Control and safety
42 11.2.5 Instructions for installation
11.2.6 Instructions for maintenance
43 Annex A (normative)Load profiles
48 Annex ZA (informative)Relationship between this European Standard and the ecodesign requirements of Commission Regulation (EU) No 814/2013 aimed to be covered
50 Annex ZB (informative)Relationship between this European Standard and and the ˜energy labelling™ requirements of Commission ˜Delegated™ Regulation (EU) No 812/2013 aimed to be covered
51 Annex ZC (informative)Relationship between this European Standard and the ecodesign requirements of Commission Regulation (EU) No 813/2013 aimed to be covered
52 Annex ZD (informative)Relationship between this European Standard and the ˜energy labelling™ requirements of Commission ˜Delegated™ Regulation (EU) No 811/2013 aimed to be covered
BS EN 16147:2017