BS EN 16211:2015
$167.15
Ventilation for buildings. Measurement of air flows on site. Methods
Published By | Publication Date | Number of Pages |
BSI | 2015 | 44 |
This European Standard specifies simplified methods for the measurement of air flows on site. It provides a description of the air flow methods and how measurements are performed within the margins of stipulated method uncertainties.
One measurement method is to take point velocity measurements across a cross-section of a duct to obtain the air flow. This simplified method is an alternative to the method described in ISO 3966 and EN 12599 . This European Standard requests certain measurement conditions (length of straight duct and uniform velocity profile) to be met to achieve the stipulated measurement uncertainties for the simplified method.
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | Contents Page |
6 | Foreword |
7 | 1 Scope 2 Normative references 3 Terms, definitions and symbols 3.1 Terms and definitions 3.2 Symbols |
9 | 4 Principles and parameters of influence 4.1 Hydraulic diameter 4.2 Flow disturbances 4.3 Air density, ρ 4.4 Dynamic pressure, pd |
10 | 4.5 Corrections for air density, ρ 5 Sources of errors 5.1 General |
11 | 5.2 Systematic errors Figure 1 — Explanation of systematic error |
12 | 5.3 Random errors 6 Measurement uncertainty 6.1 Overall measurement uncertainty |
13 | 6.2 Standard instrument uncertainty, u1 6.3 Standard method uncertainty, u2 6.4 Standard reading uncertainty, u3 6.5 Expanded measurement uncertainty, Um |
14 | 7 Measurement requirements 7.1 Method requirements and corrections 7.2 Measurements using a manometer Table 1 — Resolution for the ranges of manometers |
15 | 7.3 Measurements using an anemometer 7.4 Measurements using Pitot static tube 7.5 Measuring temperature and barometric pressure 7.6 Mean value calculation of measurement signal 8 Methods for measurement of air flows in ducts – ID (In Duct) methods 8.1 Overview of recommended methods |
16 | Table 2 — Methods of measurement of airflows in duct 8.2 Point velocity measurements using a Pitot static tube (method ID 1) or an anemometer (method ID 2) 8.2.1 Method description |
17 | Figure 2 — Measurements with Pitot static tubes 8.2.2 Preparations to be made at the site of measurement 8.2.2.1 Equipment |
18 | 8.2.2.2 Necessary straight sections before and after the plane of measurement Table 3 — Necessary straight sections before and after the plane of measurement 8.2.2.3 Preparation procedure and selection of measuring planes |
19 | Table 4 — Measurement points for circular ducts Table 5 — Measurement points for rectangular ducts related to the longer dimension: L2 Table 6 — Measurements points for rectangular ducts related to the longer dimension — Values recalculated in accordance with L2 |
20 | Table 7 — Measurements points for rectangular ducts on the height, L1 Figure 3 — Cases A and B — Cross-section of a horizontal duct — A bent upstream is in a horizontal or vertical plane 8.2.3 Measurement procedure |
21 | 8.2.4 Corrections of measured values and calculation of air flow Figure 4 — Correction factor k1 for density |
22 | Table 8 — Correction for duct shape k2 for circular ducts Table 9 — Correction for duct shape k2 for rectangular ducts 8.2.5 Standard method uncertainty 8.3 Fixed devices for flow measurement – Method ID 3 8.3.1 Method description 8.3.2 Preparations of measurements — Equipment |
23 | 8.3.3 Measurement procedure 8.3.4 Correction of measured values 8.3.5 Standard method uncertainty 8.4 Tracer gas measurement – Method ID 4 8.4.1 Method description |
24 | 8.4.2 Equipment Figure 5 — Tracer gas measurement equipment |
25 | Figure 6 — Nozzle device for injecting tracer gas 8.4.3 Calculation of air flow Table 10 — Example of density of N2O 8.4.4 Standard measurement uncertainty |
26 | 8.4.5 Conditions for homogeneous mixing of tracer gas Table 11 — Mixing length (L) required for standard method uncertainty to fall below 5 % and 10 % |
27 | 9 Methods for measurement of air flows in Supply ATDs (air terminal devices) – ST (Supply (Air) Terminal (Devices)) methods 9.1 Overview of recommended methods Table 12 — Methods of measurement of supply airflows at ATD 9.2 Measurement of reference pressure – Method ST 1 9.2.1 Introduction |
28 | Figure 7 — Example: Effects of disturbance from a 90 bend for terminal with pressure nozzles in the intake 9.2.2 Equipment 9.2.3 Correction of measured values |
29 | 9.2.4 Standard method uncertainty 9.3 Measurement with tight bag – Method ST 2 9.3.1 Method description Figure 8 — The principles of the measurement bag method 9.3.2 Limitations 9.3.3 Equipment |
30 | 9.3.4 Preparation 9.3.5 Measurement 9.3.6 Correction of measured values 9.3.7 Standard method uncertainty 9.4 Measurements with flow hood – Method ST 3 9.4.1 Introduction |
31 | 9.4.2 Equipment |
32 | Figure 9 — Example of measurement using method ST 31 Figure 10 — Flow hood with auxiliary fan (ST 32) 9.4.3 Measurement |
33 | 9.4.4 Correction of measured values 9.4.5 Standard method uncertainty |
34 | 10 Methods for Exhaust ATDs (air terminal devices) – ET (Exhaust (Air) Terminal (Devices)) methods 10.1 Overview of recommended methods Table 13 — Methods of measurement of exhaust airflows at ATD 10.2 Measurement of reference pressure at exhaust ATD – Method ET 1 10.2.1 Method description |
35 | Figure 11 — Example of measurement using Method ET 1 10.2.2 Limitations 10.2.3 Equipment 10.2.4 Correction of measured values |
36 | 10.2.5 Standard method uncertainty 10.3 Measurement using a flow hood – Method ET 2 10.3.1 Introduction 10.3.2 Equipment |
37 | Figure 12 — Example of measurement using method ET 21 Figure 13 — Example of measurement using method ET 22 10.3.3 Measurement |
38 | 10.3.4 Correction of measured values 10.3.5 Standard method uncertainty |
39 | Annex A (informative) Uncertainties A.1 Examples of calculations |
40 | A.2 Compound uncertainties A.3 Example of applications |
41 | Bibliography |