Shopping Cart

No products in the cart.

BS EN 1650:2019 – TC:2020 Edition

$246.62

Tracked Changes. Chemical disinfectants and antiseptics. Quantitative suspension test for the evaluation of fungicidal or yeasticidal activity of chemical disinfectants and antiseptics used in food, industrial, domestic and institutional areas. Test method and requirements (phase 2, step 1)

Published By Publication Date Number of Pages
BSI 2020 103
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document specifies a test method and the minimum requirements for fungicidal or yeasticidal activity of chemical disinfectant and antiseptic products that form a homogeneous, physically stable preparation when diluted with hard water or – in the case of ready-to-use-products – with water. Products can only be tested at a concentration of 80 % or less as some dilution is always produced by adding the test organisms and interfering substance. This document applies to products that are used in food, industrial, domestic and institutional areas excluding areas and situations where disinfection is medically indicated and excluding products used on living tissues except those for hand hygiene in the above considered areas. The following areas are at least included: a) processing, distribution and retailing of: 1) food of animal origin: 2) food of vegetable origin: – milk and milk products; – beverages; – meat and meat products; – fruits, vegetables and derivatives (including sugar, distillery …); – fish, seafood, and related products; – flour, milling and baking; – eggs and egg products; – animal feeds; – animal feeds; – etc. – etc. b) institutional and domestic areas: – catering establishments; – public areas; – public transports; – schools; – nurseries; – shops; – sports rooms; – waste containers (bins …); – hotels; – dwellings; – clinically non-sensitive areas of hospitals; – offices; – etc. c) other industrial areas: – packaging material; – biotechnology (yeast, proteins, enzymes, …); – pharmaceutical; – cosmetics and toiletries; – textiles; – space industry, computer industry; – etc. EN 14885 specifies in detail the relationship of the various tests to one another and to ‘use recommendations’.

PDF Catalog

PDF Pages PDF Title
55 undefined
61 1 Scope
62 2 Normative references
3 Terms and definitions
4 Requirements
64 5 Test method
5.1 Principle
65 5.2 Materials and reagents
5.2.1 Test organisms
5.2.2 Culture media and reagents
5.2.2.1 General
5.2.2.2 Water
66 5.2.2.3 Malt extract agar (MEA)
5.2.2.4 Diluent
5.2.2.5 Neutralizer
5.2.2.6 Rinsing liquid (for membrane filtration)
5.2.2.7 Hard water for dilution of products
67 5.2.2.8 Interfering substance
68 5.3 Apparatus and glassware
69 5.4 Preparation of test organism suspensions and product test solutions
5.4.1 Test organism suspensions (test and validation suspension)
5.4.1.1 General
5.4.1.2 Preservation and stock cultures of test organisms
5.4.1.3 Working culture of test organisms
70 5.4.1.4 Test suspension (“N”)
73 5.4.1.5 Validation suspension (“Nv”)
5.4.1.6 Incubation and counting of the test and the validation suspensions
5.4.2 Product test solutions
74 5.5 Procedure for assessing the fungicidal or yeasticidal activity of the product
5.5.1 General
5.5.1.1 Experimental conditions
5.5.1.2 Choice of test method (dilution-neutralization or membrane filtration)
5.5.1.3 General instructions for validation and control procedures
5.5.1.4 Equilibration of temperature
75 5.5.1.5 Precautions for manipulation of test organisms
5.5.2 Dilution-neutralization method )
5.5.2.1 General
5.5.2.2 Test “Na” – determination of fungicidal or yeasticidal concentrations
76 5.5.2.3 Experimental conditions control “A” – validation of the selected experimental conditions and/or verification of the absence of any lethal effect in the test conditions
5.5.2.4 Neutralizer control “B” – verification of the absence of toxicity of the neutralizer
5.5.2.5 Method validation “C” – dilution-neutralization validation
77 5.5.2.6 Incubation and counting of the test mixture and the control and validation mixtures
5.5.3 Membrane filtration method )
5.5.3.1 General
5.5.3.2 Test “Na” – determination of the fungicidal or yeasticidal concentrations
78 5.5.3.3 Experimental conditions control “A” – validation of the selected experimental conditions and/or verification of the absence of any lethal effect in the test conditions
5.5.3.4 Filtration control “B” – validation of the filtration procedure
5.5.3.5 Method validation “C” – validation of the membrane filtration method or counting of the fungi on the membranes which have previously been in contact with the mixture of product and interfering substance
79 5.5.3.6 Incubation and counting of the test mixture and the control and the validation mixtures
5.6 Experimental data and calculation
5.6.1 Explanation of terms and abbreviations
5.6.1.1 Overview of the different suspensions and test mixtures
80 5.6.1.2 Vc values
5.6.2 Calculation
5.6.2.1 General
5.6.2.2 Determination of Vc values
81 5.6.2.3 Calculation of N and N0
5.6.2.4 Calculation of Na
82 5.6.2.5 Calculation of Nv and Nv0
5.6.2.6 Calculation of A, B and C
83 5.7 Verification of methodology
5.7.1 General
5.7.2 Control of weighted mean counts
5.7.3 Basic limits
5.7.4 Microscopic observation
84 5.8 Expression of results and precision
5.8.1 Reduction
5.8.2 Control of active and non-active product test solution (5.4.2)
5.8.3 Limiting test organism and fungicidal/yeasticidal concentration
5.8.3.1 Fungicidal concentration
5.8.3.2 Yeasticidal concentration
5.8.4 Precision, replicates
85 5.9 Interpretation of results – conclusion
5.9.1 General
5.9.2 Fungicidal activity for general purposes
5.9.3 Yeasticidal activity for general purposes
5.9.4 Yeasticidal activity for hand hygiene
5.10 Test report
87 Annex A (informative)Referenced strains in national collections
88 Annex B (informative)Examples of neutralizers of the residual antimicrobial activity of chemical disinfectants and antiseptics and rinsing liquids
90 Annex C (informative)Graphical representations of dilution-neutralization method and membrane filtration method
C.1 Dilution – neutralization method
92 C.2 Membrane filtration method
94 Annex D (informative)Example of a typical test report
99 Annex E (informative)Precision of the test result
BS EN 1650:2019 - TC