Shopping Cart

No products in the cart.

BS EN 16573:2017

$198.66

Ventilation for Buildings. Performance testing of components for residential buildings. Multifunctional balanced ventilation units for single family dwellings, including heat pumps

Published By Publication Date Number of Pages
BSI 2017 64
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This European Standard specifies the laboratory test methods and test requirements for aerodynamic, energy rating and acoustic performance, of multifunctional balanced units intended for use in a single dwelling. In the case of units consisting of several parts, this standard applies only to those designed and supplied as a complete package with the mount instructions. It covers units that contain at least, within one or more casing: – supply and exhaust air fans; – air filters – common control system; and one or more of the additional components: – air to water heat pump; – air to air heat pump; – air-to-air heat exchanger. Units including only an air to air heat exchanger and/or an exhaust air to supply air heat pump are covered by EN 13141 7. A non-exhaustive list of possible configurations of multifunctional units covered by this standard is given in Clause 5. The standard does not cover the thermal aspects of humidity transfer in the air-to-air heat exchanger. This standard does not deal with non-ducted units on supply and extract air side. This standard does not deal with collective units (centralized or semi-centralized systems) These multifunctional balanced units can be connected to ground heat exchanger for air preheating, solar collector or other heating systems. This standard does not cover the testing with these additional components. This standard does not cover units including combustion engine driven compression heat pumps and sorption heat pump.

PDF Catalog

PDF Pages PDF Title
7 1 Scope
2 Normative references
8 3 Terms, definitions and symbols
3.1 Terms and definitions
9 3.2 Symbols
10 4 Functions
5 Description and testing of multifunctional units
15 6 Performance testing of aerodynamic characteristics
6.1 Leakages
6.1.1 Test method
6.1.2 Requirements
6.2 Air flow/pressure curve
6.3 Reference point for aerodynamic conditions
16 6.4 Pressure drop setting
17 7 Performance testing of thermal characteristics
7.1 General
7.2 Air flow settings and uncertainty
7.2.1 General
18 7.2.2 Configuration without any recirculation
7.2.3 Configuration with recirculation from outdoor air to exhaust air
19 7.2.4 Configuration with recirculation from extract to supply air
7.2.5 Configuration with two recirculations
20 7.3 Ventilation heat recovery performance
7.3.1 General
7.3.2 Air flow test conditions
21 7.3.3 Test procedure
7.3.4 Data to be recorded
23 7.3.5 Calculations
7.4 Ventilation and domestic hot water production
7.4.1 General
7.4.2 Test procedure
7.4.2.1 General
7.4.2.2 Phase I: Starting conditions and ventilation measurements
7.4.2.3 Phase II: Heating up period and stand by power measurement
24 7.4.2.4 Phase III: Hot water performances measurement
7.4.2.5 Phase IV: Reference hot water temperature and maximum volume of usable hot water measurements
7.4.3 Data to be recorded
26 7.4.4 Performance rating calculations
7.4.4.1 Overall performance
7.4.4.2 Domestic hot water stand-by losses
7.4.4.3 Domestic hot water performance
7.5 Ventilation with hydronic space heating/cooling
7.5.1 General
27 7.5.2 Temperature test conditions
29 7.5.3 Test procedure
7.5.3.1 General
7.5.3.2 Phase I: Starting conditions and ventilation measurements
7.5.3.3 Phase II: Heating/cooling performance measurements
7.5.4 Data to be recorded
31 7.5.5 Performance rating calculations
7.5.5.1 General
7.5.5.2 Overall performance
32 7.5.5.3 Heating performance
7.5.5.4 Cooling performance
33 7.6 Ventilation combined with supply air heating/cooling
7.6.1 General
7.6.2 Temperature test conditions
7.6.3 Test procedure
7.6.3.1 General
34 7.6.3.2 Phase I: Starting conditions and ventilation measurements
7.6.3.3 Phase II: Air heating/cooling performance measurements
7.6.4 Data to be recorded
36 7.6.5 Performance rating calculations
7.6.5.1 General
7.6.5.2 Overall performance
7.6.5.3 Air heating performance
37 7.6.5.4 Air cooling performance
7.7 Ventilation combined with both hydronic and supply air heating/cooling
7.7.1 General
7.7.2 Test procedure
7.7.2.1 General
38 7.7.2.2 Phase I: Starting conditions and ventilation measurements
7.7.2.3 Phase II: Heating/cooling performance measurements
7.7.3 Data to be recorded
41 7.7.4 Performance rating calculations
7.7.4.1 General
7.7.4.2 Overall performance
7.7.4.3 Heating performance and or cooling performance
42 7.8 Ventilation combined with heating and hot water production
7.8.1 General
7.8.2 Test procedure
7.8.2.1 General
43 7.8.2.2 Phase I: Starting conditions and ventilation measurements
7.8.2.3 Phase II: Heating up and stand-by power input measurements
7.8.2.4 Phase III: Hydronic and/or air heating performance measurements
44 7.8.2.5 Phase IV: Hot water production performance measurements
7.8.2.6 Phase IVbis optional: Hot water production performance measurements without heating
7.8.2.7 Phase V: Reference hot water temperature and maximum volume of usable hot water measurements
7.8.3 Data to be recorded
47 7.8.4 Performance rating calculations
7.8.4.1 General
7.8.4.2 Overall performance
48 7.8.4.3 Heating performance
49 7.8.4.4 Hot water production performance
50 7.9 Ventilation combined with cooling and hot water production
7.9.1 General
7.9.2 Test procedure
7.9.2.1 General
51 7.9.2.2 Phase I: Starting conditions and ventilation measurements
7.9.2.3 Phase II: Heating up and stand-by power input measurements
7.9.2.4 Phase III: Cooling performance measurements
52 7.9.2.5 Phase IV: Hot water production performance measurements
7.9.2.6 Phase IVbis optional: Hot water production performance measurements without cooling
7.9.2.7 Phase IVter optional: Hot water production performance measurements with supply air free cooling
7.9.2.8 Phase V: Reference hot water temperature and maximum volume of usable hot water measurements
7.9.3 Data to be recorded
55 7.9.4 Performance rating calculations
7.9.4.1 General
56 7.9.4.2 Overall performance
7.9.4.3 Cooling performance
57 7.9.4.4 Hot water production performance
59 8 Performance testing of acoustic characteristics
8.1 General
8.2 Configurations to be tested
8.3 Performance testing ventilation only
8.4 Performance testing ventilation and hydronic heating
8.5 Performance testing ventilation and supply air heating
8.6 Performance testing ventilation and supply air heating and hydronic heating
60 8.7 Performance testing ventilation and domestic hot water
9 Test report
9.1 General information
61 9.2 Additional information
9.3 Rating test results
9.3.1 Product specifications
9.3.2 Leakages
9.3.3 Air flow/pressure curve
9.3.4 Temperature ratios of ventilation function
9.3.5 Performance data of ventilation and domestic hot water functions
9.3.6 Performance data of ventilation and hydronic space heating and/or cooling
9.3.7 Performance data of ventilation and air heating and/or cooling
9.3.8 Performance data of ventilation with both hydronic and air heating/cooling
9.3.9 Performance data of ventilation with heating and hot water production
9.3.10 Performance data of ventilation with cooling and hot water production
62 9.4 Acoustic characteristics
BS EN 16573:2017
$198.66