Shopping Cart

No products in the cart.

BS EN 16905-5:2022:2023 Edition

$198.66

Gas-fired endothermic engine driven heat pumps – Calculation of seasonal performances in heating and cooling mode

Published By Publication Date Number of Pages
BSI 2023 58
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of EN 16905 specifies the calculation of the seasonal performance factor for gas-fired endothermic engine driven heat pumps for heating and/or cooling mode including the engine heat recovery, to be used outdoors. This document only applies to appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions. This document only applies to appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437:2021. This document only applies to appliances having: a) gas fired endothermic engines under the control of fully automatic control systems; b) closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated; c) where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 °C during normal operation; d) where the maximum operating pressure in the: 1) heating water circuit (if installed) does not exceed 6 bar, 2) domestic hot water circuit (if installed) does not exceed 10 bar. This document applies to GEHP appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery. This document is applicable to GEHP appliances that are intended to be type tested. Requirements for GEHP appliances that are not type tested would need to be subject to further consideration.

PDF Catalog

PDF Pages PDF Title
2 undefined
10 1 Scope
2 Normative references
3 Terms and definitions
11 4 Part load conditions for space cooling
4.1 General
4.2 Air-to-air units
12 4.3 Water-to-air and brine-to-air units
4.4 Air-to-water and air-to-brine units
13 4.5 Water-to-water and brine-to-water units
15 5 Part load conditions for space heating
5.1 General
5.2 Air-to-air units
16 5.3 Water(brine)-to-air units
17 5.4 Air-to-water(brine) units
5.4.1 General
5.4.2 Low temperature application
18 5.4.3 Intermediate temperature application
19 5.4.4 Medium temperature application
5.5 DX-to-water(brine), water-to-water(brine), brine-to-water(brine) units
5.5.1 General
20 5.5.2 Low temperature application
21 5.5.3 Intermediate temperature application
22 5.5.4 Medium temperature application
23 6 Calculation methods for reference SPERc
6.1 General
6.2 General formula for calculation of GUEc and AEFc
6.3 General formula for calculation of EHREc and AEHRFc
6.4 General formula for calculation of reference SGUEc
24 6.5 Calculation of reference SEHREc
25 6.6 Calculation of reference SGUETc
6.7 Calculation of reference SAEFc
6.8 Calculation of reference annual cooling demand (Qref,c)
26 6.9 Calculation of reference SAEFcON
6.10 Calculation of reference SAEHRFc
27 6.11 Calculation of reference total SAEFTc
6.12 Procedures for the determination of GUEcPL / AEFcPL values
6.13 Procedures for the determination of EHREcPL / AEHRFcPL values
6.14 Calculation of reference SPERc
28 6.15 Calculation of the annual primary energy consumption cooling QCP
6.16 Calculation of the seasonal space cooling efficiency ηs,c
7 Calculation methods for reference SPERh
7.1 General
29 7.2 General formula for calculation of GUEh and AEFh
7.3 General formula for calculation of EHREh
7.4 General formula for calculation of reference SGUEh
32 7.5 Calculation of reference SEHREh
7.6 Calculation of reference SGUETh
7.7 Calculation of reference SAEFh
33 7.8 Calculation of reference annual heating demand (Qref,h)
7.9 Calculation of reference SAEFhON
34 7.10 Calculation of reference SAEHRFh
7.11 Calculation of reference total SAEFTh
7.12 Procedures for the determination of GUEhPL / AEFhPL values
7.13 Procedures for the determination of EHREhPL / AEHRFhPL values
35 7.14 Calculation of reference SPERh
7.15 Calculation of the annual primary energy consumption heating QHP
7.16 Calculation of the seasonal space heating efficiency ηs,h
36 8 Technical documentation
37 Annex A (normative)Determination of reference annual cooling/heating demands and determination of hours for active mode, thermostat off, standby, off mode and crankcase heater mode for reference SAEFc and SAEFh calculation
A.1 Air-to-air, water-to-air and brine-to-air units
A.1.1 Hours for active mode, thermostat-off and standby
38 A.1.2 Hours for crankcase heater mode
A.2 Air-to-water, air-to-brine, water-to-water, brine-to-water, DX –to-water and DX-to brine units
A.2.1 Hours for active mode, thermostat-off and standby
A.2.2 Hours for crankcase heater mode
39 Annex B (informative)Calculation example for reference SGUEc, SAEFc, SEHREc, SAEHRFc, SGUETc, SAEFTc and SPERc
42 Annex C (informative)Calculation example for reference SGUEh, SAEFh, SEHREh, SAEHRFh, SGUETc, SAEFTh and SPERh
45 Annex D (informative)Template for technical documentation
50 Annex E (normative)Rating of outdoor units of multi-split air conditioners and heat pumps
E.1 General
E.2 Terms and definitions
51 E.3 Rating of outdoor units
E.3.1 General
52 E.3.2 Test procedure
E.4 Calculation of the SPERc based on the PERc outdoor
E.5 Calculation of the SPERh based on the SPERh outdoor
53 Annex ZA (informative)Relationship between this European Standard and the requirements of Commission Regulation (EU) No 813/2013 aimed to be covered
54 Annex ZB (informative)Relationship between this European Standard and the requirements of Commission Regulation (EU) No 2016/2281 aimed to be covered
55 Annex ZC (informative)Relationship between this European Standard and the requirements of Commission Regulation (EU) No 811/2013 aimed to be covered
BS EN 16905-5:2022