BS EN 17037:2018+A1:2021:2022 Edition
$215.11
Daylight in buildings
Published By | Publication Date | Number of Pages |
BSI | 2022 | 74 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
9 | 1 Scope 2 Normative references 3 Terms and definitions |
12 | 4 Symbols and abbreviations |
14 | 5 Assessment of daylight in interior spaces 5.1 Daylight Provision 5.1.1 General 5.1.2 Criteria for daylight provision |
15 | 5.1.3 Daylight Provision Calculation Methods 5.1.4 Verification of daylight provision 5.2 Assessment for view out 5.2.1 General |
16 | 5.2.2 Criteria for view out 5.2.3 Verification of view out 5.3 Exposure to sunlight 5.3.1 General 5.3.2 Criteria for exposure to sunlight 5.3.3 Verification of sunlight duration |
17 | 5.4 Protection from glare 5.4.1 General 5.4.2 Criteria for protection from glare 5.4.3 Verification for protection from glare |
18 | Annex A (informative)Recommendations A.1 General A.2 Recommendations for daylight provision in a space |
22 | A.3 Recommendations for view |
23 | A.4 Recommendation for exposure to sunlight A.5 Recommendation for glare protection |
25 | Annex B (informative)Daylight B.1 General B.2 Calculation grids |
26 | B.3 Calculation methods B.3.1 General B.3.2 Calculation method using daylight factor (method 1) |
27 | B.3.3 Calculation method using illuminance level (method 2) B.4 Daylight availability |
28 | B.5 Validation of actual daylighting performance |
29 | Annex C (informative)View out C.1 General C.2 Quality of view out C.3 Width of view out |
34 | C.4 Verification of view out C.4.1 Simplified verification method |
35 | C.4.2 Advanced verification method |
38 | Annex D (informative)Exposure to sunlight D.1 General D.2 Principle of assessment of hours of sunlight |
40 | D.3 Method using software |
42 | D.4 Method using manual geometric constructions D.5 Determination of the position of the sun in the sky |
47 | D.6 Evaluation rules for sunlight duration |
49 | D.7 Sunlight duration in the reference point P D.7.1 Example D.7.2 Calculation D.7.3 Result |
51 | D.8 On-site verification of duration of exposure to sunlight |
52 | Annex E (informative)Glare E.1 General E.2 Daylight Glare Probability |
53 | E.3 Annual evaluation E.3.1 General |
54 | E.3.2 Simplified annual glare evaluation E.3.2.1 General |
55 | E.3.2.2 Solar protection device being opaque in the extended and close position E.3.2.3 Solar protection device where the curtain is made of textile, film or perforated opaque material |
58 | E.3.2.4 Non-diffusing glazing device with a low variable light transmittance (e.g. electrochromic glazing) |
61 | E.3.2.5 Sunshine zones |
62 | E.4 Reflections or veiling glare E.5 Verification of the glare protection capability of shadings |
65 | Annex F (informative)A–deviations |
66 | Annex G (normative)!Special national conditions |