BS EN 50193-1:2016 – TC:2020 Edition

$186.33

Tracked Changes. Electric instantaneous water heaters. Methods for measuring the Performance – General requirements

Published By Publication Date Number of Pages
BSI 2020 59
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This European Standard applies to electric instantaneous water heaters for domestic hot water heating for household and similar applications, which show both of the following characteristics: – fulfilling at least one load pattern from Annex A – heating up to temperatures below the boiling temperature. This European Standard specifies terms, definitions and measurement methods for the assessment of energy efficiency. This European Standard does not take into account requirements regarding the safety of the appliances.

PDF Catalog

PDF Pages PDF Title
36 European foreword
37 1 Scope
2 Normative references
3 Terms and definitions
39 4 General test conditions
4.1 Measurement Equipment
Table 1 — Measurement Equipment Accuracy
4.2 Number of appliances to be tested
4.3 General conditions
40 4.4 Test setup
5 Energy efficiency
5.1 Test methods
5.1.1 General
5.1.2 Static efficiency
41 5.1.3 Start-up losses
5.1.4 Determination of the smart control factor SCF
42 5.1.5 Determination of smart control compliance
5.2 Calculation methods
5.2.1 General
5.2.2 Daily energy demand
5.2.3 Correction factor
5.2.4 Energy efficiency
43 5.2.5 Annual electricity consumption
44 Annex A (informative) Load pattern
45 Table A.1 — Water heater load patterns (reference test tapping patterns) 3XS to S
46 Table A.2 — Water heater load patterns (reference test tapping patterns) M to XL
47 Table A.3 — Water heater load patterns (reference test tapping patterns) XXL to 4XL
48 Annex B (normative) Test setup
Figure B.1 — Test setup for open-outlet instantaneous water heater
49 Figure B.2 — Test setup for closed instantaneous water heater
50 Figure B.3 — Thermocouple water connection part
51 Figure B.4 — Example of a thermocouple feed through
52 Annex C (informative) Alternative test methods under development
C.1 General
C.2 Annual energy consumption
54 Annex ZZA (informative) Relationship between this European Standard and the energy labelling requirements of Commission Delegated Regulation (EU) No 812/2013 aimed to be covered
Table ZZA.1 — Correspondence between this European Standard and Commission Delegated Regulation (EU) No 812/2013 of 18 February 2013 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to energy labelling of wa…
55 Annex ZZB (informative) Relationship between this European Standard and the ecodesign requirements of Commission Regulation (EU) No 814/2013 aimed to be covered
Table ZZB.1 — Correspondence between this European Standard and Commission Regulation (EU) No 814/2013 of 2 August 2013 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for water he…
56 Bibliography
BS EN 50193-1:2016 - TC
$186.33