BS EN 50491-11:2015+A1:2020
$215.11
General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) – Smart Metering. Application Specifications. Simple External Consumer Display
Published By | Publication Date | Number of Pages |
BSI | 2020 | 88 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
6 | Foreword |
8 | Introduction |
9 | 1 Scope 2 Normative References 3 Terms, definitions and abbreviations 3.1 Terms and definitions |
10 | 3.2 Abbreviations |
11 | 4 General reference model |
13 | 5 Requirements for the Data interface 5.1 General |
14 | 5.2 Minimization of data transmission 5.3 Data consistency 5.4 Filtering of message types and data points |
15 | 6 Conformity and Testing 7 Metering Functional Blocks of MDC 7.1 MDC Heat Meter (M_HEATM) 7.1.1 Aims and objectives 7.1.2 Functional specification 7.1.3 Constraints |
16 | 7.1.4 Data Point Overview |
18 | 7.2 MDC Heat Cost Allocator (M_HCA) 7.2.1 Aims and objectives 7.2.2 Functional specification 7.2.3 Constraints |
19 | 7.2.4 Data Point Overview |
20 | 7.3 MDC Water Meter (M_WATERM) 7.3.1 Aims and objectives 7.3.2 Functional specification 7.3.3 Constraints |
21 | 7.3.4 Data Point Overview |
22 | 7.4 MDC Generic Meter (M_GENERICM) 7.4.1 Aims and objectives 7.4.2 Functional specification |
23 | 7.4.3 Constraints 7.4.4 Data Point Overview |
24 | 7.5 MDC Gas Meter (M_GASM) 7.5.1 Aims and objectives 7.5.2 Functional specification |
25 | 7.5.3 Constraints 7.5.4 Data Point Overview |
26 | 7.6 MDC Electricity Meter (M_ELECM) 7.6.1 Aims and objectives 7.6.2 Functional specification |
27 | 7.6.3 Constraints 7.6.4 Data Point Overview |
29 | 7.7 MDC Breaker (M_BREAKERM) 7.7.1 Aims and objectives 7.7.2 Functional Specification 7.7.3 Constraints 7.7.4 Datapoint description |
30 | 7.8 MDC Valve (M_VALVEM) 7.8.1 Aims and objectives 7.8.2 Functional Specification |
31 | 7.8.3 Constraints 7.8.4 Datapoint description |
32 | 8 Metering Data model 8.1 Introduction 8.2 Boolean Value |
33 | 8.3 1-octet unsigned counter value 8.4 Datapoint Types 2-Octet Float Value” |
34 | 8.5 2-octet unsigned counter value 8.6 4-Octet Signed unsigned counter Value 8.7 4 Octet signed time period |
35 | 8.8 Datapoint Type “MeteringValue” 8.8.1 General 8.8.2 Coding General |
36 | 8.8.3 Coding VallnfField |
37 | 8.8.4 Coding Status 8.8.5 Recommended display format for metering data |
38 | 8.9 DPT Active Energy |
39 | 8.10 DPT for tariff information 8.11 DPT_Currency |
40 | 8.12 DPTs for Price Information 8.13 Format of DPT_DateTime 8.13.1 Coding |
41 | 8.13.2 Remarks to the coding of DPT_DateTime 8.13.2.1 Remarks to the field Year in DPT_DateTime 8.13.2.2 Remarks to the field Hour in DPT_DateTime |
42 | 8.13.2.3 Remarks to the field Fault in DPT_DateTime 8.13.2.4 Remarks to the field Standard Summer Time in DPT_DateTime 8.13.2.5 Remarks to the field No Day of the Week in DPT_DateTime 8.13.2.6 Remarks to the field Quality of Clock in DPT_DateTime |
44 | 8.14 Datapoint Type DPT_Metering_DeviceType |
45 | 8.15 Datapoint Type Character Set |
46 | 8.16 Datapoint Type DPT_VarString_8859_1 8.17 DPT_Gas_Measurement_Condition |
47 | 8.18 Datapoint Type DPT_Meter_BreakerValve_State 8.19 Datapoint Type DPT_Meter_Mode |
48 | 8.20 Datapoint Type DPT_Power_Threshold_Status 8.21 Datapoint Type DPT_Battery_Status |
49 | Annex A (informative) Cross reference mapping EN 50491-11 and COSEM/OBIS A.1 Introduction A.2 Generic data points: MDC Generic Meter (M_GENERICM) |
52 | A.3 Electricity data points: MDC Electricity Meter (M_ELECM) |
58 | A.4 MDC Heat Heatmeter (M_HEATM) |
66 | A.5 MDC Heat Cost Allocator (M_HCA) |
72 | A.6 MDC Water Meter (M_WATERM) |
77 | A.7 MDC Gas Meter (M_GASM) |
83 | A.8 MDC Valve (M_VALVEM) |
87 | Bibliography |