Shopping Cart

No products in the cart.

BS EN 55016-2-3:2006:2007 Edition

$215.11

Specification for radio disturbance and immunity measuring apparatus and methods – Methods of measurement of disturbances and immunity – Radiated disturbance measurements

Published By Publication Date Number of Pages
BSI 2007 98
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of CISPR 16 is designated a basic standard, which specifies the methods of measurement of radiated disturbance phenomena in the frequency range 9 kHz to 18 GHz.

PDF Catalog

PDF Pages PDF Title
8 1 Scope
2 Normative references
9 3 Terms and definitions
12 4 Types of disturbance to be measured
4.1 Types of disturbance
4.2 Detector functions
13 5 Connection of measuring equipment
5.1 Connection of associated equipment
5.2 Connections to RF reference ground
5.3 Connection between the EUT and the artificial mains network
14 6 General measurement requirements and conditions
6.1 Disturbance not produced by the equipment under test
6.1.1 Compliance testing
6.2 Measurement of continuous disturbance
6.2.1 Narrowband continuous disturbance
15 6.2.2 Broadband continuous disturbance
6.2.3 Use of spectrum analyzers and scanning receivers
6.3 Operating conditions of the EUT
6.3.1 Normal load conditions
6.3.2 The time of operation
6.3.3 Running-in time
6.3.4 Supply
6.3.5 Mode of operation
16 6.4 Interpretation of measuring results
6.4.1 Continuous disturbance
6.4.2 Discontinuous disturbance
6.4.3 Measurement of the duration of disturbances
6.5 Measurement times and scan rates for continuous disturbance
17 6.5.1 Minimum measurement times
6.5.2 Scan rates for scanning receivers and spectrum analyzers
18 6.5.3 Scan times for stepping receivers
19 6.5.4 Strategies for obtaining a spectrum overview using the peak detector
22 7 Measurement of radiated disturbances
7.1 Introduction
7.2 Field-strength measurements in the frequency range 9 kHz to 1 GHz
7.2.1 Open area test site measurements
7.2.2 General measurement method
23 7.2.3 Measurement distance
24 7.2.4 Antenna height variation
7.2.5 Product specification details
7.2.5.1 Test environment
25 7.2.5.2 Configuration of equipment under test
26 7.2.6 Measurement instrumentation
7.2.7 Field-strength measurements on other out-door sites
7.2.8 Measurements in reverberating chambers
7.2.9 Measurement in absorber-lined shielded enclosures
7.2.9.1 Measurement in absorber-lined shielded enclosures with groundplane (semi-anechoic chambers = SAC or semi-anechoic Room = SAR)
7.2.9.2 Measurement in fully absorber-lined shielded enclosures (fully anechoic chamber = FAC or fully anechoic room = FAR)
7.2.9.2.1 Test set-up
28 7.2.9.2.2 EUT position
31 7.2.9.2.3 Cable layout and termination
32 7.2.9.3 Radiated emissions (30 MHz to 1 GHz) and immunity (80 MHz to 1 GHz) test method with common test set-up in semi-anechoic chamber
7.2.9.3.1 Applicability
7.2.9.3.2 EUT perimeter definition and antenna-to-EUT separation distance
7.2.9.3.3 Uniform test volume
33 7.2.9.3.4 Specifications for common emissions/immunity EUT test set-up
41 7.2.10 Measurements in TEM cells
42 7.3 Field-strength measurements in the frequency range 1 GHz to 18 GHz
7.3.1 Quantity to measure
7.3.2 Measurement distance
7.3.3 Set-up and operating conditions of the equipment under test (EUT)
43 7.3.4 Measurement site
7.3.5 Measurement instrumentation
7.3.6 Measurement procedure
7.3.6.1 General description of the radiated field measurement method above 1 GHz
47 7.3.6.2 General measurement procedure
7.3.6.3 Preliminary measurement procedure
48 7.3.6.4 Final measurement procedure
49 7.3.6.5 Procedure for APD measurement
50 7.3.6.5.1 Method 1 – Measurement of the level of disturbance
51 7.3.6.5.2 Method 2 – Measurement of the probability of time
7.4 Substitution method of measurement in the frequency range of 30 MHz to 18 GHz
7.4.1 Test site
52 7.4.2 Test antennas
53 7.4.3 EUT configuration
7.4.4 Test procedure
7.5 Measurements of equipment in situ
7.5.1 Applicability of and preparation for in situ measurements
54 7.5.2 Field-strength measurements in the frequency range 9 kHz to 30 MHz
7.5.2.1 Measurement method
55 7.5.2.2 Measurement distances other than the standard distance
7.5.3 Field-strength measurements in the frequency range above 30 MHz
7.5.3.1 Measurement method
7.5.3.2 Measurement distances other than the standard distance
56 7.5.4 In situ measurement of the effective radiated disturbance power using the substitution method
7.5.4.1 General measurement condition
7.5.4.2 Frequency range 30 MHz to 1 000 MHz
7.5.4.2.1 Measurement distance
57 7.5.4.2.2 Measurement method
59 7.5.4.3 Frequency range 1 GHz to 18 GHz
7.5.4.3.1 Measurement distance
7.5.4.3.2 Measurement method
60 7.5.5 Documentation of the measurement results
7.6 Measurement in a loop antenna system
7.6.1 General measurement method
61 7.6.2 Test environment
62
63 7.6.3 Configuration of the equipment under test
8 Automated measurement of emissions
8.1 Introduction: Precautions for automating measurements
64 8.2 Generic measurement procedure
8.3 Prescan measurements
66 8.4 Data reduction
67 8.5 Emission maximization and final measurement
68 8.6 Post processing and reporting
BS EN 55016-2-3:2006