BS EN 60076-16:2011
$167.15
Power transformers – Transformers for wind turbines applications
Published By | Publication Date | Number of Pages |
BSI | 2011 | 40 |
This part of IEC 60076 applies to dry-type and liquid-immersed transformers for rated power 100 kVA up to 10 000 kVA for wind turbine application s having a winding with highest voltage for equipment up to and including 36 kV and at least one winding operating at a voltage greater than 1,1 kV.
Transformers covered by this standard comply with the relevant requirements prescribed in the IEC 60076 standards.
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | English CONTENTS |
8 | INTRODUCTION |
9 | 1 Scope 2 Normative references |
10 | 3 Terms and definitions 4 Service conditions 4.1 Normal service conditions 4.2 Altitude 4.3 Temperature of cooling air |
11 | 4.4 Content of harmonic currents in the transformer 4.5 Wave-shape of supply voltage 4.6 Transient over and under voltages |
12 | 4.7 Humidity and salinity 4.8 Special electrical and environmental conditions around the transformer Tables Table 1 – Insulation levels |
13 | 4.9 Level of vibration 4.10 Provision for unusual service conditions for transformers for wind turbine applications 4.11 Transportation and storage conditions 4.12 Corrosion protection 5 Electrical characteristics 5.1 Rated power 5.2 Highest voltage for equipment |
14 | 5.3 Tappings 5.4 Connection group 5.5 Dimensioning of neutral terminal 5.6 Short circuit impedance 5.7 Insulation levels for high voltage and low voltage windings 5.8 Temperature rise guaranteed at rated conditions |
15 | 5.9 Overload capability 5.10 Inrush current 5.11 Ability to withstand short circuit 5.12 Operation with forced cooling 6 Rating plate 7 Tests 7.1 List and classification of tests (routine, type and special tests) 7.2 Routine tests |
16 | 7.3 Type tests 7.4 Special tests |
18 | Annex A (informative) Calculation method and tables |
19 | Figures Figure A.1 – Heat dissipation in a natural ventilated room |
25 | Table A.1 – Impact of harmonics content on liquid-immersed transformer losses |
28 | Table A.2 – Impact of harmonics content on dry type transformers losses |
31 | Table A.3 – Example of voltage harmonic order |
32 | Figure A.2 – Schematic diagram of power frequency current injection apparatus |
33 | Figure A.3 – Switched transformer winding voltage responses with capacitor injection |
34 | Figure A.4 – HV Injection test figure |
35 | Figure A.5 – Example of measurement device |
38 | Bibliography |