BS EN 60076-18:2012:2013 Edition

$189.07

Power transformers – Measurement of frequency response

Published By Publication Date Number of Pages
BSI 2013 48
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 60076-18:2012 covers the measurement technique and measuring equipment to be used when a frequency response measurement is required either on-site or in the factory either when the test object is new or at a later stage. This standard is applicable to power transformers, reactors, phase shifting transformers and similar equipment.

PDF Catalog

PDF Pages PDF Title
5 English
CONTENTS
8 1 Scope
2 Terms and definitions
9 3 Purpose of frequency response measurements
10 4 Measurement method
4.1 General
12 4.3 Measurement connection and checks
4.3.1 Measurement connection and earthing
4.3.2 Zero-check measurement
4.3.3 Repeatability check
4.3.4 Instrument performance check
13 4.4 Measurement configuration
4.4.1 General
4.4.2 Principles for choosing the measurement configuration
14 4.4.3 Star- and auto-connected windings with a neutral terminal
4.4.4 Delta windings and other windings without an accessible neutral
Tables
Table 1 – Standard measurements for a star connected winding with taps
15 4.4.5 Zig-zag connected windings
4.4.6 Two-winding three-phase transformers
4.4.7 Three-phase auto-transformers
4.4.8 Phase shifting transformers
4.4.9 Reactors
4.4.10 Method for specifying additional measurements
Table 2 – Standard measurements for delta connected winding without tap
16 4.5 Frequency range and measurement points for the measurement
5 Measuring equipment
5.1 Measuring instrument
5.1.1 Dynamic range
Table 3 – Format for specifying additional measurements
17 5.1.2 Amplitude measurement accuracy
5.1.3 Phase measurement accuracy
5.1.4 Frequency range
5.1.5 Frequency accuracy
5.1.6 Measurement resolution bandwidth
5.1.7 Operating temperature range
5.1.8 Smoothing of recorded data
5.1.9 Calibration
5.2 Measurement leads
18 5.3 Impedance
6 Measurement records
6.1 Data to be recorded for each measurement
19 6.2 Additional information to be recorded for each set of measurements
21 Annex A (normative) Measurement lead connections
22 Figure A.1 – Method 1 connection
23 Figure A.2 – Method 3 connection
24 Annex B (informative) Frequency response and factors that influence the measurement
Figure B.1 – Presentation of frequency response measurements
25 Figure B.2 – Comparison with a baseline measurement
Figure B.3 – Comparison of the frequency responses of twin transformers
26 Figure B.4 – Comparison of the frequency responses from sister transformers
Figure B.5 – Comparison of the frequency responses of three phases of a winding
28 Figure B.6 – General relationships between frequency response and transformer structure and measurement set-up for HV windings of large auto-transformer
29 Figure B.7 – Effect of tertiary delta connection on the frequency response of a series winding
30 Figure B.8 – Effect of star neutral connection on the tertiary winding response
Figure B.9 – Effect of star neutral termination on series winding response
31 Figure B.10 – Measurement results showing the effect of differences between phases in internal leads connecting the tap winding and OLTC
Figure B.11 – Effect of measurement direction on frequency response
32 Figure B.12 – Effect of different types of insulating fluid on frequency response
Figure B.13 – Effect of oil filling on frequency response
33 Figure B.14 – Effect of a DC injection test on the frequency response
Figure B.15 – Effect of bushings on frequency response
34 Figure B.16 – Effect of temperature on frequency response
35 Figure B.17 – Examples of bad measurement practice
Figure B.18 – Frequency response of a tap winding before and after partial axial collapse and localised inter-turn short-circuit with a photograph of the damage
36 Figure B.19 – Frequency response of an LV winding before and after axial collapse due to clamping failure with a photograph of the damage [8]
37 Figure B.20 – Frequency response of a tap winding with conductor tiltingwith a photograph of the damage [1]
38 Annex C (informative) Applications of frequency response measurements
40 Annex D (informative) Examples of measurement configurations
Table D.1 – Standard end-to-end measurements on a three-phase auto-transformer
41 Figure D.1 – Winding diagram of an auto-transformer with a line-end tap changer
Table D.2 – Tap-changer connections
42 Figure D.2 – Connection diagram of an inductive inter-winding measurement on a three-phase YNd1 transformer
Table D.3 – Inductive inter-winding measurements on a three-phase YNd1 transformer
Table D.4 – Capacitive inter-winding measurements on a three-phase YNd1 transformer
43 Figure D.3 – Connection diagram for a capacitive inter-winding measurement on a three-phase YNd1 transformer
Figure D.4 – Connection diagram for an end-to-end short-circuit measurement on a three-phase YNd1 transformer
Table D.5 – End-to-end short-circuit measurements on a three-phase YNd1 transformer
44 Annex E (informative) XML data format
45 Bibliography