Shopping Cart

No products in the cart.

BS EN 60079-35-1:2011:2012 Edition

$142.49

Household and similar electrical appliances – Safety – – Part 2-82: Particular requirements for amusement machines and personal service machines

Published By Publication Date Number of Pages
BSI 2012 26
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 60079-35 specifies requirements for the construction, testing and marking of caplights, including caplights with a point of connection for other equipment, for use in mines susceptible to firedamp (Group I – electrical equipment for explosive gas atmospheres as defined in IEC 60079-0). It deals only with the risk of the caplight becoming a source of ignition.

The requirements for performance are in IEC 60079-35-2.1

This standard supplements and modifies the general requirements of IEC 60079-0 except as indicated in Table 1. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirements of this standard take precedence.

Compliance with this standard will provide an EPL of Mb (see 4.1 of this standard). If an EPL of Ma is required, the caplight will need to conform to the requirements of 4.2 of this standard, which in turn refers to IEC 60079-11.

It is expected that from time to time, caplights conforming to this standard (EPL Mb) will operate in atmospheres where the firedamp exceeds statutory levels that require the withdrawal of people from the high firedamp atmosphere to a non-hazardous area.

In designing equipment for operation in conditions other than those given above, this standard may be used as guidance; however, additional testing may be required.

Where a caplight is assessed as intrinsically safe equipment, Ex ia, conforming to IEC 60079-11 only the clauses/subclauses listed in 4.2 require application.

Table 1 – Application or exclusion of specific clauses of IEC 60079-0

Applies – This requirement of IEC 60079-0 is applied without change.

Excluded – This requirement of IEC 60079-0 does not apply.

Modified – This requirement of IEC 60079-0 is modified as detailed in this standard.

NR – No requirements.

a The clause number in this table is shown for information only. The applicable requirements of IEC 60079-0 are identified by the clause title which is normative. This table was written against the specific requirements of the sixth edition of IEC 60079-0:2011. The clause numbers for the previous edition are shown for information only. This is to enable the General requirements of the fifth edition of IEC 60079-0:2007 to be used where necessary with this part of IEC 60079. Where there were no requirements (indicated by NR) or there is a conflict between requirements, the later edition requirements take precedence.

PDF Catalog

PDF Pages PDF Title
9 English

CONTENTS
11 INTRODUCTION
12 1 Scope
13 Table 1 – Application or exclusion of specific clauses of IEC 60079-0
15 2 Normative references
3 Terms and definitions
16 4 Level of protection
4.1 General
Figure 1 – Example of a caplight assembly
17 4.2 Additional requirements for EPL “Ma”
4.3 Thermal ignition compliance
4.4 Spark ignition compliance
5 Equipment construction
5.1 Enclosures
18 5.2 Cable
5.3 External charging contacts
5.4 Internal electrical connections
19 5.5 Solid electrical insulating materials
5.6 Internal wiring
5.7 Supply of electrical power to other equipment
5.8 Creepage and clearance distances
5.9 Assembled electrical connection
5.10 Thermal protection
20 6 Overcurrent protection
6.1 General
6.2 Fuse or thermal circuit-breaker
6.3 Resistive safety
21 7 Cells and batteries
8 Type verifications and tests
8.1 Impact test
8.2 Drop tests
8.3 Degree of protection (IP) by enclosures
22 8.4 Test to verify the non-ignition of a representative electrolytic gas mixture or firedamp by fuse or thermal circuit-breaker
8.5 Test to verify the non-ignition of a gas mixture by one strand of the cable between the headpiece and the battery by thermal ignition
8.6 Test to verify the resistance of the cable sheath to fatty acids
8.7 Test to verify the resistance of the cable sheath to fire
8.8 Test to verify the strength of cable entries, anchoring devices and cable
23 8.9 Electrolyte leakage test for cells and batteries
8.10 Current-limiting resistor test
9 Marking
9.1 General
24 9.2 Examples of marking
10 Instructions
BS EN 60079-35-1:2011