Shopping Cart

No products in the cart.

BS EN 60269-6:2011

$142.49

Low-voltage fuses – Supplementary requirements for fuse-links for the protection of solar photovoltaic energy systems

Published By Publication Date Number of Pages
BSI 2011 32
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 60269-6:2010 gives supplementary requirement to those given in IEC 60269-1 for fuse-links for protecting photovoltaic (PV) strings and photovoltaic (PV) arrays in equipment for circuits of nominal voltages up to 1 500 V d.c. This publication is to be read in conjunction with /2.

PDF Catalog

PDF Pages PDF Title
6 English
CONTENTS
8 1 General
1.1 Scope and object
1.2 Normative references
9 2 Terms and definitions
2.2 General terms
12 3 Conditions for operation in service
3.4 Voltage
3.5 Current
3.6 Frequency, power factor and time constant
13 3.10 Temperature inside an enclosure
4 Classification
5 Characteristics of fuses
5.1 Summary of characteristics
5.2 Rated voltage
5.5 Rated power dissipation of the fuse-link
5.6 Limits of time-current characteristics
14 5.7 Breaking range and breaking capacity
6 Markings
6.2 Markings on fuse-links
7 Standard conditions for construction
7.5 Breaking capacity
Tables
Table 101 – Conventional times and currents for “gPV” fuse-links
15 8 Tests
8.1 General
Table 102 – Survey of complete tests on fuse-links and number of fuse-links to be tested
16 8.3 Verification of temperature rise limits and power dissipation
Table 103 – Survey of tests on fuse-links of the smallest rated current of a homogeneous series and number of fuse-links to be tested
17 8.4 Verification of operation
8.5 Verification of the breaking capacity
18 8.11 Mechanical and miscellaneous tests
Table 104 – Values for breaking-capacity tests on “gPV” fuse-links
20 Figures
Figure 101 – Current of test cycling
21 Annex AA (normative) Examples of standardized fuse-links for the protection of solar photovoltaic energy systems
22 Figure AA.1 – Fuse-links with cylindrical contact caps, type A
23 Figure AA.2 – Fuse-links with cylindrical contact caps type A with striker – Additional dimensions for sizes 14 x 51, 20 x 127 and 22 x 127 only
24 Figure AA.3 – North American cylindrical fuse-links with blade contacts – Sizes 61- 600 A
26 Figure AA.4 – Fuse-links with blade contacts, type C, C referring IEC 60269-2 “Fuse system A (NH fuse system)”
28 Figure AA.5 – Fuse-links with long blade contacts, type D
29 Annex BB (informative) Guidance for the protection of photovoltaic strings and arrays with fuse-links designed for PV applications
30 Bibliography
BS EN 60269-6:2011
$142.49