Luminaires – Particular requirements. Luminaires for emergency lighting

Published By Publication Date Number of Pages
BSI 2010 32
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This section of IEC 60598-2 specifies requirements for emergency lighting luminaires for use with electrical light sources on emergency power supplies not exceeding 1 000 V.

This section does not cover the effects of non-emergency voltage reductions on luminaires incorporating high pressure discharge lamps.

This section also includes relevant requirements and tests that shall be conducted and complied with for control gears, as specified in IEC 60924, that incorporate additional facilities such as remote control devices, indicators, changeover devices, etc.

22.1.1 Normative references

The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of the ISO/IEC Directives. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this part of the ISO/IEC Directives are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies. Members of ISO and IEC maintain registers of currently valid International Standards.

IEC 60073, Basic and safety principles for man-machine interface, marking and identification – Coding principles for indication devices and actuators

IEC 60079, Electrical apparatus for explosive gas atmospheres

IEC 60155, Glow-starters for fluorescent lamps

IEC 60285, Alkaline secondary cells and batteries – Sealed nickel-cadmium cylindrical rechargeable single cells

IEC 60364-5-56, Electrical installations of buildings – Part 5: Selection and erection of electrical equipment – Chapter 56: Safety services

IEC 60598-1, Luminaires – Part 1: General requirements and tests

IEC 60742, Isolating transformers and safety isolating transformers – Requirements

IEC 60896-2, Stationery lead-acid batteries – General requirements and test methods – Part 2: Valve regulated types

IEC 60924, D.C. supplied electronic ballasts for tubular fluorescent lamps – General and safety requirements

PDF Catalog

PDF Pages PDF Title
1 BRITISH STANDARD
BRITISH STANDARD
BRITISH STANDARD
BRITISH STANDARD
BS EN 60598-2-22:1999 +A2:2008
Incorporating corrigenda December 1999, June 2006, December 2007
Luminaires –
Luminaires –
Part 2-22: Particular requirements – Luminaires for emergency lighting

ICS 29.140.40; 91.160.10

2 This British Standard was published under the authority of the Standards Committee and comes into effect on 15 March 1999
This British Standard was published under the authority of the Standards Committee and comes into effect on 15 March 1999
This British Standard was published under the authority of the Standards Committee and comes into effect on 15 March 1999
© BSI 2008
ISBN 978 0 580 63994 9
National foreword
National foreword
This British Standard is the UK implementation of EN 60598-2-22:1998+A2:2008, incorporating corrigenda December 2005 and October 2007. It is derived from IEC 60598-2-22:1997, incorporating amendment 2:2008. It supersedes BS EN 60598-2-22:1999.
The CENELEC common modifications have been implemented at the appropriate places in the text. The start and finish of each common modification is indicated in the text by tags éè.
The start and finish of text introduced or altered by amendment is indicated in the text by tags. Tags indicating changes to IEC text carry the number of the IEC amendment. For example, text altered by IEC amendment 1 is indicated by !”.
The UK participation in its preparation was entrusted by Technical Committee CPL/34/4, Luminaires, to Subcommittee CPL/34/4/2, Luminaires for emergency lighting.
A list of organizations represented on this subcommittee can be obtained on request to its secretary.
This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.
Compliance with a British Standard cannot confer immunity from legal obligations.
Compliance with a British Standard cannot confer immunity from legal obligations.






Amendments/corrigenda issued since publication
Amendments/corrigenda issued since publication


Amd. No.
Date
Comments

10562 Corrigendum No. 1
Corrigendum No. 1
December 1999
Change to date of withdrawal (dow) of conflicting national standards

14393
20 June 2003
Implementation of IEC amendment 1:2003 with CENELEC endorsement A1:2003

16331 Corrigendum No. 2
30 June 2006
Revision of Foreword, Annex ZA and Annex ZB

17505 Corrigendum No. 3
31 December 2007
Revision of EN foreword

31 July 2008
Implementation of IEC amendment 2:2008 with CENELEC endorsement A2:2008
32 BS EN 60598-2-22:1999 +A2:2008
BS EN 60598-2-22:1999 +A2:2008
BSI Group Headquarters
BSI Group Headquarters
389 Chiswick High Road,
London W4 4AL, UK
Tel +44 (0)20 8996 9001
Fax +44 (0)20 8996 7001
www.bsigroup.com/standards
British Standards Institution (BSI)
British Standards Institution (BSI)
BSI is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter.
Revisions
British Standards are updated by amendment or revision. Users of British Standards should make sure that they possess the latest amendments or editions.
It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an ina…
BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards.
Buying standards
Orders for all BSI, international and foreign standards publications should be addressed to Customer Services. Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001 Email: [email protected]
You may also buy directly using a debit/credit card from the BSI Shop on the Website http://www.bsigroup.com/shop.
In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise requested.
Information on standards
BSI provides a wide range of information on national, European and international standards through its Library and its Technical…
Subscribing members of BSI are kept up to date with standards developments and receive substantial discounts on the purchase pri…
Information regarding online access to British Standards via British Standards Online can be found at
http://www.bsigroup.com/BSOL
Further information about BSI is available on the BSI website at
http://www.bsigroup.com
Copyright
Copyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of the publications of the international st…
This does not preclude the free use, in the course of implementing the standard, of necessary details such as symbols, and size,…
Details and advice can be obtained from the Copyright & Licensing Manager. Tel: +44 (0)20 8996 7070 Email: [email protected]
BS EN 60598-2-22:1998+A2:2008
$142.49