Shopping Cart

No products in the cart.

BS EN 60695-11-5:2017

$142.49

Fire hazard testing – Test flames. Needle-flame test method. Apparatus, confirmatory test arrangement and guidance

Published By Publication Date Number of Pages
BSI 2017 30
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 60695 specifies a needle-flame test to simulate the effect of a small flame which may result from fault conditions, in order to assess the fire hazard by a simulation technique. The results of this test may be used as elements of a fire hazard assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use.

It is applicable to electrotechnical equipment, its sub-assemblies and components and to solid electrical insulating materials or other combustible materials.

This basic safety publication is intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 104 and ISO/IEC Guide 51 .

One of the responsibilities of a technical committee is, wherever applicable, to make use of basic safety publications in the preparation of its publications. The requirements, test methods or test conditions of this basic safety publication will not apply unless specifically referred to or included in the relevant publications.

PDF Catalog

PDF Pages PDF Title
2 National foreword
7 English
CONTENTS
9 FOREWORD
11 INTRODUCTION
12 1 Scope
2 Normative references
13 3 Terms and definitions
15 4 Purpose of the test
5 Description of the test apparatus
5.1 Burner
5.2 Gas supply
5.3 Flame
5.4 Control valve
5.5 Laboratory fumehood/chamber
16 5.6 Layer
5.6.1 Specified layer
5.6.2 Standardized layer
5.7 Timing device
6 Test specimen
7 Flame application times
17 8 Conditioning and test conditions
8.1 Conditioning
8.2 Test conditions
9 Test procedure
9.1 General
9.2 Position of test specimen
9.3 Application of needle-flame
18 9.4 Number of test specimens
10 Observations and measurements
11 Evaluation of test results
12 Information to be given in the relevant specification
19 13 Test report
Figure 1 – Burner and flame
20 Figure 2 – Test positions
21 Annex A (normative) Confirmatory test arrangement
A.1 Confirmation of the test flame – Principle
A.2 Test apparatus
A.2.1 Burner
A.2.2 Control valve
A.2.3 Copper block
A.2.4 Thermocouple
A.2.5 Temperature/time indicating/recording devices
A.3 Procedure
23 Figures
Figure A.1 – Copper block
24 Figure A.2 – Confirmatory test arrangement
25 Figure A.3 – Gauge to measure flame height and the distancebetween burner and copper block (example)
26 Annex B (informative) Example of a product committee specification
Tables
Table B.1 – Severities and requirements
27 Annex C (informative) Comparison of results of confirmatory tests using propane and butane as fuel
Table C.1 – Results of the confirmatory test using propane and butane as fuel
28 Bibliography