Shopping Cart

No products in the cart.

BS EN 60695-2-12:2010+A1:2014

$102.76

Fire hazard testing – Glowing/hot-wire based test methods. Glow-wire flammability index (GWFI) test method for materials

Published By Publication Date Number of Pages
BSI 2014 18
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 60695 specifies the details of the glow-wire test to be applied to test specimens of solid electrical insulating materials or other solid materials for flammability testing to determine the glow-wire flammability index (GWFI).

GWFI is the highest temperature, determined during this standardized procedure, at which the tested material

  1. does not ignite or, if it does, extinguishes within 30 s after removal of the glow-wire and is not totally consumed,

    and

  2. molten drips, if they occur, do not ignite the wrapping tissue.

This test method is a materials test carried out on a series of standard test specimens. The data obtained, along with data from the glow-wire ignition temperature (GWIT) test method for materials, IEC 60695‑2‑13 , can then be used in a preselection process in accordance with IEC 60695‑1‑30 to judge the ability of materials to meet the requirements of IEC 60695‑2‑11 .

NOTE

As an outcome of conducting a fire hazard assessment, an appropriate series of preselection flammability and ignition tests may allow a reduction of end product testing.

This basic safety publication is intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 104 and ISO/IEC Guide 51 .

One of the responsibilities of a technical committee is, wherever applicable, to make use of basic safety publications in the preparation of its publications. The requirements, test methods or test conditions of this basic safety publication will not apply unless specifically referred to or included in the relevant publications.

PDF Catalog

PDF Pages PDF Title
7 English
CONTENTS
8 INTRODUCTION
9 1 Scope
2 Normative references
10 3 Terms and definitions
11 4 Test specimens
4.1 Test specimen preparation
4.2 Test specimen dimensions
4.3 Testing ranges in formulations
12 5 Apparatus
6 Temperature measuring system verification
7 Conditioning and test conditions
7.1 Conditioning of test specimens
7.2 Conditioning of the wrapping tissue and the wooden board
7.3 Testing conditions
13 8 Test procedure
8.1 General
8.2 Initial test temperatures
8.3 Test temperatures
Table 1 – Initial test temperatures
14 9 Observations and measurements
9.1 General
9.2 Initial observations
9.3 Test observations
10 Evaluation of test results
10.1 Test criteria
10.2 Glow-wire flammability index
15 11 Test report
16 Bibliography
BS EN 60695-2-12:2010+A1:2014