BS EN 60700-1:1998+A2:2008:2009 Edition

$167.15

Thyristor valves for high-voltage direct current (HVDC) power transmission – Electrical testing

Published By Publication Date Number of Pages
BSI 2009 42
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
1 BRITISH STANDARD
2 National foreword
4 Foreword
Foreword to amendment A1
5 Contents
7 1 Scope
2 Normative references
3 Definitions
3.1 Insulation co-ordination terms
3.1.1 test withstand voltage
3.1.2 steep front impulse
3.1.3 internal and external insulation
3.1.4 valve protective firing
8 3.2 Valve construction terms
3.2.1 valve support
3.2.2 valve structure
9 3.2.3 redundant thyristor levels
3.2.4 valve base electronics
3.2.5 thyristor level
3.2.6 valve section
3.3 type tests
3.3.1 dielectric tests
3.3.2 operational tests
3.4 production tests
3.4.1 routine tests
3.4.2 sample tests
4 General requirements
4.1 Guidelines for the performance of type tests
10 4.2 Atmospheric correction
4.3 Treatment of redundancy
11 4.4 Criteria for successful type testing
12 Table 1 – Thyristor level faults permitted during type tests
13 5 List of type tests
6 Dielectric tests on valve support
6.1 Purpose of tests
14 6.2 Test object
6.3 Test requirements
15 7 Dielectric tests for multiple valve units (MVU)
7.1 Purpose of tests
7.2 Test object
16 7.3 Test requirements
18 8 Dielectric tests between valve terminals
8.1 Purpose of tests
8.2 Test object
19 8.3 Test requirements
22 8.4 Valve non-periodic firing test
24 9 Periodic firing and extinction tests
9.1 Purpose of tests
9.2 Test object
9.3 Test requirements
29 10 Tests with transient forward voltage during the recovery period
10.1 Purpose of tests
10.2 Test object
10.3 Test requirements
30 11 Valve fault current tests
11.1 Purpose of tests
11.2 Test object
11.3 Test requirements
32 12 Tests for valve insensitivity to electromagnetic disturbance
12.1 Purpose of tests
33 12.2 Test object
12.3 Test requirements
13 Testing of special features
13.1 Purpose of tests
13.2 Test object
34 13.3 Test requirements
14 Production tests
14.1 Purpose of tests
14.2 Test object
14.3 Test requirements
14.4 Production test objectives
35 15 Method for loss determination
16 Presentation of type test results
36 Annex A (normative) Test safety factors
A.1 General
A.2 Test safety factors for dielectric tests
A.2.1 Impulse tests
38 A.2.2 AC and d.c. temporary and long-term voltage tests
39 A.3 Test safety factors for operational tests
Annex B (normative) Partial discharge measurements
B.1 Measurement of partial discharge
B.2 Partial discharge during a.c. tests
40 B.3 Partial discharge during d.c. tests
B.4 Composite a.c. plus d.c. voltage stress
41 Annex C (informative) Fault tolerance capability