BS EN 60794-3-60:2008 2009
$167.15
Optical fibre cables – Outdoor cables. Family specification for drinking water pipe cables and subducts for installation by blowing and/or pulling/dragging/floating in drinking water pipes
Published By | Publication Date | Number of Pages |
BSI | 2009 | 40 |
IEC 60794-3-60:2008 covers drinking water pipe cables and subducts for installation by blowing and/or pulling/dragging/floating in drinking water pipes. Systems built with components covered by this standard are subject to the requirements of sectional specification IEC 60794-3. This publication is to be read in conjunction with /2, /2 and /2.
PDF Catalog
PDF Pages | PDF Title |
---|---|
7 | CONTENTS |
9 | FOREWORD |
11 | 1 Scope 2 Normative references |
12 | 3 Symbols and abbreviations |
13 | 4 Family specification for drinking water pipe cables and subducts for installation by blowing and/or pulling/dragging/floating in drinking water pipes (blank detail specification and minimum requirements) 4.1 Construction |
14 | 4.2 Optical fibres Tables Table 1 – Single-mode dispersion unshifted (B1.1) optical fibre Table 2 – Single-mode dispersion shifted (B2) optical fibre |
15 | Table 3 – Single-mode non-zero dispersion (B4) optical fibre Table 4 – Single-mode (B6) optical fibre |
16 | 4.3 Drinking water pipe cable constructions Table 5 – Characteristics – Cable for installation within subducts |
17 | Table 6 – Characteristics – Cable for direct installation within the high pressure gas pipe |
18 | 4.4 Installation and operating conditions Table 7 – Characteristics – Subduct construction Table 8 – Tests applicable to cables/cable elements |
19 | 4.5 Mechanical and environmental tests Table 9 – Subducts tests applicable |
22 | Table 10 – Tests applicable to the cable for installation within subducts |
26 | Table 11 – Tests applicable to the cables for direct installation into the drinking water pipe |
30 | Annex A (informative) Blank detail specification Table A.1 – Cable for installation within subducts |
31 | Table A.2 – Cables for direct installation into the drinking water pipes |
32 | Table A.3 – Subduct description |
33 | Annex B (informative) OF cables for drinking water pipes Table B.1 – OF cables for drinking water pipes |
34 | Annex C (informative) Examples of subducts and drinking water pipe cables Figures Figure C.1 – Examples of constructions of cables for installation in subducts within drinking water pipes |
35 | Figure C.2 – Examples of constructions for drinking water pipe cables |
36 | Annex D (informative) Example for installation schemes of optical fibre cables in drinking water pipes (Fibre in drinking water pipes) Figure D.1 – Schematic drawing – I/O-port for OF cables into drinking water lines |
37 | Figure D.2 – Schematic drawing – Installation of OF cables in drinking water lines Figure D.3 – Installation of I/O-ports on high pressure PE drinking water pipes |