BS EN 60990:2016 – TC:2020 Edition

$258.95

Tracked Changes. Methods of measurement of touch current and protective conductor current

Published By Publication Date Number of Pages
BSI 2020 145
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 60990:2016 is available as /2 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60990:2016 defines measurement methods for d.c. or a.c. current of sinusoidal or non-sinusoidal waveform, which could flow through the human body, and current flowing through a protective conductor. The measuring methods recommended for TOUCH CURRENT are based upon the possible effects of current flowing through a human body. In this standard, measurements of current through networks representing the impedance of the human body are referred to as measurements of TOUCH CURRENT. These networks are not necessarily valid for the bodies of animals. The specification or implication of specific limit values is not within the scope of this standard. IEC TS 60479 series provides information regarding the effects of current passing through the human body from which limit values may be derived. This standard is applicable to all classes of EQUIPMENT, according to IEC 61140. The methods of measurement in this standard are not intended to be used for TOUCH CURRENTS having less than 1 s duration, patient currents as defined in IEC 60601-1, a.c. at frequencies below 15 Hz, and currents above those chosen for ELECTRIC BURN limits. This third edition cancels and replaces the second edition published in 1999. It constitutes a technical revision. The principal changes in this edition as compared with the second edition are as follows: – the effects names have been updated to reflect increased understanding of the range of effects and is in concert with present usage; – the conditions of use invoking a GRIPPABLE PART have been reduced in the application of the requirements based upon the current understanding of this effect; – the references to ISO 10012-1, which has been replaced by management standard of the same number, have been replaced with explanatory text, where needed to maintain the sense of the document; – former informative Annex H (GRIPPABLE PART) has been deleted from this update as it does not properly represent the full set of conditions under which immobilization can occur. A new informative Annex H (Analysis of frequency filtered touch current circuits measurement) has been added and the Bibliography (formerly Annex M) has been updated with additional references for completeness. This basic safety publication is primarily intended for use by technical committees in the preparation of standards in accordance with /2 and ISO/IEC Guide 51. It is not intended for use by manufacturers or certification bodies independent of product standards. It has the status of a Basic Safety Publication in accordance with /2 Key words: Touch Current, Protective Conductor Current, Current Flow

PDF Catalog

PDF Pages PDF Title
83 European foreword
Endorsement notice
84 Annex ZA (normative) Normative references to international publications with their corresponding European publications
85 English
CONTENTS
89 FOREWORD
91 INTRODUCTION
93 1 Scope
2 Normative references
94 3 Terms and definitions
4 Test site
4.1 Test site environment
95 4.2 Test transformer
4.3 Earthed neutral conductor
Figures
Figure 1 – Example of earthed neutral, direct supply
96 5 Measuring equipment
5.1 Selection of measuring network
5.1.1 General
Figure 2 – Example of earthed neutral, with transformer for isolation
Figure 3 – Measuring network, unweighted touch current
97 5.1.2 Perception and startle-reaction
5.1.3 Letgo-immobilization
5.1.4 Electric burn (a.c.)
5.1.5 Ripple-free d.c.
Figure 4 – Measuring network, touch current weighted for perception or startle-reaction
Figure 5 – Measuring network, touch current weighted for letgo-immobilization
98 5.2 Test electrodes
5.2.1 Construction
5.2.2 Connection
5.3 Configuration
5.4 Power connections during test
5.4.1 General
99 Figure 6 – Single-phase equipment on star TN or TT system
Figure 7 – Single-phase equipment on centre-earthed TN or TT system
100 Figure 8 – Single-phase equipment connected line-to-line on star TN or TT system
Figure 9 – Single-phase equipment connected line-to-neutral on star IT system
Figure 10 – Single-phase equipment connected line-to-line on star IT system
101 Figure 11 – Three-phase equipment on star TN or TT system
Figure 12 – Three-phase equipment on star IT system
102 5.4.2 Equipment for use only on TN or TT star power distribution systems
5.4.3 Equipment for use on IT power distribution systems including unearthed delta systems
Figure 14 – Three-phase equipment on centre-earthed delta system
Figure 13 – Unearthed delta system
103 5.4.4 Equipment for use on single-phase centre-earthed power supply systems or on centre-earthed delta power supply systems
5.5 Supply voltage and frequency
5.5.1 Supply voltage
5.5.2 Supply frequency
6 Test procedure
6.1 General
6.1.1 Touch current measurements
104 6.1.2 Control switches, equipment and supply conditions
6.1.3 Use of measuring networks
6.2 Normal and fault conditions of equipment
6.2.1 Normal operation of equipment
6.2.2 Equipment and supply fault conditions
106 7 Evaluation of results
7.1 Perception, startle-reaction and letgo-immobilization
7.2 Electric burn
8 Measurement of protective conductor current
8.1 General
107 8.2 Multiple equipment
8.3 Measuring method
108 Annexes
Annex A (normative) Equipment
Figure A.1 – Equipment
109 Annex B (normative) Use of a conductive plane
Figure B.1 – Equipment platform
110 Annex C (normative) Incidentally connected parts
111 Annex D (informative) Choice of current limits
D.1 General
D.2 Limit examples
D.2.1 Ventricular fibrillation
D.2.2 Inability to letgo-immobilization
D.2.3 Startle-reaction
D.2.4 Perception threshold
D.2.5 Special applications
112 D.3 Choice of limits
113 D.4 Electric burn effects of touch current
114 Annex E (informative) Networks for use in measurement of touch current
E.1 General
E.2 Body impedance network – Figure 3
E.3 Startle-reaction (and body impedance) network – Figure 4
115 E.4 Letgo-immobilization (and body impedance) network – Figure 5
116 Annex F (informative) Measuring network limitations and construction
Figure F.1 – Frequency factor for electric burn
Figure F.2 – Frequency factor for perception or startle-reaction
117 Figure F.3 – Frequency factor for letgo-immobilization
118 Annex G (informative) Construction and application of touch current measuring instruments
G.1 Considerations for selection of components
G.1.1 General
G.1.2 Power rating and inductance for RS and RB
G.1.3 Capacitor CS
119 G.1.4 Resistors R1, R2 and R3
G.1.5 Capacitors C1, C2 and C3
G.2 Voltmeter
G.3 Accuracy
120 G.4 Calibration and application of measuring instruments
G.5 Records
G.6 Confirmation systems
122 Annex H (informative) Analysis of frequency filtered touch current circuit measurements
123 Figure H.1 – Triangular waveform touch current, startle-reaction
Tables
Table H.1 – Triangular waveform response comparison
124 Figure H.3 – 1 ms rise time pulse response, startle-reaction
Figure H.4 – 1 ms rise time pulse response, letgo-immobilization
Table H.2 – Square wave touch current response
125 Figure H.5 – Touch current vs. rise time plot, 20 ms square wave
Figure H.6 – PFC SMPS touch current waveform
126 Figure H.7 – 50 Hz square wave, 0,1 ms rise time, startle-reaction
Figure H.8 – 50 Hz square wave, 0,1 ms rise time, letgo-immobilization
Table H.3 – Square wave monopolar touch current response
127 Figure H.9 – IEC TS 60479-2 let-go threshold for AC and DC combinations augmented by additional data, mA each axis
128 Figure H.10 – Ex1 case: showing r.m.s. window
Figure H.11 – Waveform ex2 case: showing r.m.s. window
Table H.4 – Mixed ACnDC waveform evaluation, ex1
129 Table H.5 – Mixed ACnDC waveform evaluation, ex2
130 Annex I (informative) AC power distribution systems (see 5.4)
I.1 General
131 I.2 TN power systems
Figure I.1 – Examples of TN-S power system
132 Figure I.2 – Example of TN-C-S power system
Figure I.3 – Example of TN-C power system
133 I.3 TT power systems
Figure I.4 – Example of single-phase, 3-wire TN-C power system
Figure I.5 – Example of 3-line and neutral TT power system
134 I.4 IT power systems
Figure I.6 – Example of 3-line TT power system
Figure I.7 – Example of 3-line (and neutral) IT power system
135 Figure I.8 – Example of 3-line IT power system
136 Annex J (informative) Routine and periodic touch current tests, and tests after repair or modification of mains operated equipment
137 Annex K (normative) Network performance and calibration
K.1 Network or instrument performance and initial calibration
Table K.1 – Calculated input impedance and transfer impedancefor unweighted touch current measuring network (Figure 3)
138 Table K.2 – Calculated input impedance and transfer impedance for startle-reaction touch current measuring network (Figure 4)
Table K.3 – Calculated input impedance and transfer impedance for letgo-immobilization current measuring network (Figure 5)
139 K.2 Calibration in a confirmation system
K.2.1 General
K.2.2 Measurement of input resistance
K.2.3 Measurement of instrument performance
140 Table K.4 – Output voltage to input voltage ratios for unweighted touch current measuring network (Figure 3)
Table K.5 – Output voltage to input voltage ratios for startle-reaction measuring network (Figure 4)
141 Table K.6 – Output voltage to input voltage ratiosfor letgo-immobilization measuring network (Figure 5)
142 Bibliography
BS EN 60990:2016 - TC
$258.95