$186.33

Tracked Changes. Industrial-process control. Safety of analyzer houses

Published By Publication Date Number of Pages
BSI 2020 69
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 61285:2015 describes the physical requirements for the safe operation of the process analyser measuring system installed in an analyser house (AH) in order to ensure its protection against fire, explosion and health hazards. This standard applies for analyser houses with inner and/or external potential explosive atmospheres and it applies to hazards caused by toxic substances or asphyxiant gases. This third edition cancels and replaces the second edition published in 2004 and constitutes a technical revision. The main changes are: – incorporation of previously issued corrigendum and – minor updates to several sections and references.

PDF Catalog

PDF Pages PDF Title
1 Tracked_Changes_Cover
3 30271478_Final
45 English
CONTENTS
47 INTRODUCTION
48 1 Scope
2 Normative references
49 3 Terms and definitions
52 4 Location of AHs and connection within the process plant areas
4.1 General
4.2 Response time
4.3 Utilities
4.4 Safety
4.4.1 Location
4.4.2 Escape
4.4.3 Area classification
4.4.4 Peripheral hazards
4.5 Access
53 5 Design, construction and layout of AHs
5.1 General
5.2 General requirements
5.3 Dimensions and layout
5.4 Structural requirements
5.4.1 Construction materials
54 5.4.2 Walls
5.4.3 Floors and foundation
5.4.4 Doors
5.4.5 Windows
5.4.6 Roof
5.5 Equipment
5.5.1 Lighting
5.5.2 Communications
5.5.3 Piping, tubing and valves
55 5.5.4 Utilities
5.5.5 Fire extinguishers
5.5.6 Ventilation
56 5.5.7 Temperature
5.6 Labelling/instructions/documentation
5.6.1 Entrance
5.6.2 Alarms
5.6.3 Safety procedures
57 5.6.4 Additional data
6 Explosion protection of AHs
6.1 General
6.2 General requirements
6.3 Protection of AHs against explosion hazards by means of artificial ventilation
6.3.1 Classification
58 6.3.2 Requirements for AHs where the explosion hazard originates externally
6.3.3 Requirements for AHs where the explosion hazard originates from internal gases or vapours
59 6.3.4 Requirements for AHs where the explosion hazard originates from internal liquids
60 6.3.5 Requirements for AHs where the explosion hazard originates from any combination of the above
6.4 Protection of AHs against explosion hazards by means of natural ventilation
6.4.1 General
6.4.2 Ventilation requirements
61 6.4.3 Heating requirements
6.4.4 Gas detectors
7 Measures to prevent health hazards to personnel in AHs
7.1 General
7.2 Guidelines
7.3 General requirements
62 7.4 Safety measures
63 7.5 External hazards
7.6 Additional measures for abnormal working conditions
64 7.7 Labelling/instructions/documentation
65 Annex A (normative) Leakage risk of modules in the AH
A.1 General
A.2 Modules with negligible leakage risk
A.3 Modules with limited leakage risk
A.3.1 General
66 A.3.2 Guidance for evaluating modules
Tables
Table A.1 – Module evaluation
67 Bibliography