BS EN 61300-2-14:2013
$102.76
Fibre optic interconnecting devices and passive components. Basic test and measurement procedures – Tests. High optical power
Published By | Publication Date | Number of Pages |
BSI | 2013 | 18 |
IEC 61300-2-14:2012 describes a procedure for determining the suitability of a fibre optic interconnecting device or a passive component to withstand the exposure to optical power that may occur during operation. This third edition cancels and replaces the second edition published in 2005 and constitutes a technical revision. This edition includes the following significant technical change with respect to the previous edition: fundamental change of the measurement method to introduce various measurement environments such as limited testing resources. Keywords: exposure to optical power
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | English CONTENTS |
7 | 1 Scope 2 Normative references 3 Apparatus 3.1 Source (S) |
8 | 3.2 Optical detector (D) 3.3 Environmental chamber 3.4 Data acquisition system (DAS) 3.5 Branching device (BD) 3.6 Temporary joints (TJ) 3.7 Safety devices 3.8 Test set-up |
9 | 4 Procedure 4.1 Preconditioning 4.2 Initial examinations and measurements Figure 1 – Optical power test set-up |
10 | 4.3 Conditioning 4.4 Recovery 4.5 Final examinations and measurements 5 Severity 5.1 General 5.2 Optical power |
11 | 5.3 Wavelengths 5.4 Temperature 5.5 Humidity 5.6 Exposure time 6 Details to be specified |
12 | Annex A (normative) Examples of test set-up Figure A.1 – Optical power test set-up for WDM device |
13 | Figure A.2 – Optical power test set-up in series connection |
14 | Annex B (informative) Examples of pass/fail criteria during exposure time |
16 | Bibliography |