BS EN 61347-2-13:2014+A1:2017:2018 Edition
$142.49
Lamp controlgear – Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules
Published By | Publication Date | Number of Pages |
BSI | 2018 | 30 |
This part of IEC 61347 specifies particular safety requirements for electronic controlgear for use on d.c. or a.c. supplies up to 1 000 V (a.c. at 50 Hz or 60 Hz) and at an output frequency which can deviate from the supply frequency, associated with LED modules.
Controlgear for LED modules specified in this standard are designed to provide constant voltage or current at SELV or higher voltages. Deviations from the pure voltage and current types do not exclude the gear from this standard.
The annexes of IEC 61347-1 which are applicable according to this Part 2-13 and using the word “lamp” are understood to also comprise LED modules.
Particular requirements for SELV controlgear are given in Annex I.
Performance requirements are covered by IEC 62384 .
Plug-in controlgear, being part of the luminaire, are covered as for built-in controlgear by the additional requirements of the luminaire standard.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
4 | Foreword Foreword |
5 | European foreword to amendment A1 |
8 | FOREWORD |
10 | INTRODUCTION |
11 | 1 Scope 2 Normative references 3 Terms and definitions |
13 | 4 General requirements 5 General notes on tests |
14 | 6 Classification 7 Marking 7.1 Mandatory marking 7.2 Information to be provided if applicable 8 Protection against accidental contact with live parts 9 Terminals 10 Provisions for protective earthing 11 Moisture resistance and insulation |
15 | 12 Electric strength 13 Thermal endurance test for windings of ballasts 14 Fault conditions 15 Transformer heating 15.1 General 15.2 Normal operation 15.3 Abnormal operation 16 Construction |
16 | 17 Creepage distances and clearances 18 Screws, current-carrying parts and connections 19 Resistance to heat, fire and tracking 20 Resistance to corrosion 21 Maximum working voltage (U out) in any load condition |
17 | Annex A (normative) Test to establish whether a conductive part is a live part which may cause an electric shock |
18 | Annex B (normative) Particular requirements for thermally protected lamp controlgear |
19 | Annex C (normative) Particular requirements for electronic lamp controlgear with means of protection against overheating |
20 | Annex D (normative) Requirements for carrying out the heating tests of thermally protected lamp controlgear |
21 | Annex E (normative) Use of constant S other than 4 500 in t w tests |
22 | Annex F (normative) Draught-proof enclosure |
23 | Annex G (normative) Explanation of the derivation of the values of pulse voltages |
24 | Annex H (normative) Tests |
25 | Annex I (normative) Particular additional requirements for SELV d.c. or a.c. supplied electronic controlgear for LED modules |
26 | Annex J (normative) Particular additional safety requirements for a.c., a.c./d.c. or d.c. supplied electronic controlgear for emergency lighting |
29 | Bibliography |