Shopping Cart

No products in the cart.

BS EN 61439-4:2013

$167.15

Low-voltage switchgear and controlgear assemblies – Particular requirements for assemblies for construction sites (ACS)

Published By Publication Date Number of Pages
BSI 2013 36
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 61439-4:2012 defines the specific requirements of ACS as follows: – ASSEMBLIES for which the rated voltage does not exceed 1 000 V in case of a.c. or 1 500 V in case of d.c.; – ASSEMBLIES where the nominal primary voltage and the nominal secondary voltage of transformers incorporated in ACS are within the limits specified above; – ASSEMBLIES intended for use on construction sites, both indoors and outdoors, i.e. temporary places of work to which the public do not generally have access and where building construction, installation, repairs, alteration or demolition of property (buildings) or civil engineering (public works) or excavation or any other similar operations are carried out; – transportable (semi-fixed) or mobile ASSEMBLIES with enclosure. The manufacture and/or assembly may be carried out other than by the original manufacturer. This first edition of IEC 61439-4 cancels and replaces the second edition of IEC 60439-4 (2004), and constitutes a technical revision. This edition includes the following significant technical changes with respect to the last edition of IEC 60439-4: – modification of the title as “Part 4: Particular requirements for assemblies for construction sites (ACS)”; – alignment on IEC 61439-1 regarding the structure and technical content, as applicable; – to allow comparison with tested ACS. This publication is to be read in conjunction with /2.

PDF Catalog

PDF Pages PDF Title
9 English
CONTENTS
10 1 Scope
2 Normative references
11 3 Terms and definitions
13 4 Symbols and abbreviations
5 Interface characteristics
14 6 Information
15 7 Service conditions
16 8 Constructional requirements
18 9 Performance requirements
10 Design verification
20 Figure 101 – Impact test using striking element
21 11 Routine verification
101 Particular features of ACS
23 Table 101 – Values of assumed loading
24 Annexes
Annex C (informative) User information template
25 Annex D (informative) Design verification
Table D.1 – List of design verifications to be performed
26 Annex O (informative) Guidance on temperature rise verification
27 Annex P (normative) Verification of the short-circuit withstand strength of busbar structures by comparison with a tested reference design by calculation
28 Annex AA (informative) List of notes concerning certain countries
30 Annex CC (informative) Items subject to agreement between the assembly manufacturer and the user
Table CC.1 – Items subject to agreement between the assembly manufacturer and the user
34 Bibliography
BS EN 61439-4:2013
$167.15