BS EN 61746-2:2011:2014 Edition
$189.07
Calibration of optical time-domain reflectometers (OTDR) – OTDR for multimode fibres
Published By | Publication Date | Number of Pages |
BSI | 2014 | 48 |
This part of IEC 61746 provides procedures for calibrating multimode optical time domain reflectometers (OTDR). It covers OTDR measurement errors and uncertainties. The test of the laser(s) source modal condition is included as an optional measurement.
This standard does not cover correction of the OTDR response.
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | CONTENTS |
8 | INTRODUCTION |
9 | 1 Scope 2 Normative references 3 Terms, definitions and symbols |
10 | Figures Figure 1 – Definition of attenuation dead zone |
15 | 4 Preparation for calibration 4.1 Organization 4.2 Traceability 4.3 Preparation 4.4 Test conditions 4.5 Documentation |
16 | 5 Distance calibration – General 5.1 General 5.2 Location deviation model |
17 | Figure 2 – Representation of the location deviation ΔL(L) |
18 | 5.3 Using the calibration results Table 1 – Additional distance uncertainty |
19 | 5.4 Measuring fibre length 6 Distance calibration methods 6.1 General 6.2 External source method |
20 | Figure 3 – Equipment for calibration of the distance scale – External source method |
21 | Figure 4 – Set-up for calibrating the system insertion delay |
25 | 6.3 Concatenated fibre method (using multimode fibres) Figure 5 – Concatenated fibres used for calibration of the distance scale |
28 | 6.4 Recirculating delay line method |
29 | Figure 6 – Distance calibration with a recirculating delay line |
30 | Figure 7 – OTDR trace produced by recirculating delay line |
32 | 7 Vertical scale calibration – General 7.1 General |
33 | 7.2 Loss difference calibration Figure 8 – Determining the reference level and the displayed power level |
34 | Figure 9 – Region A, the recommended region for loss measurement samples Table 2 – Attenuation coefficients defining region A |
35 | 7.3 Characterization of the OTDR source near field Figure 10 – Possible placement of sample points within region A |
36 | 8 Loss difference calibration method 8.1 General 8.2 Long fibre method |
37 | Figure 11 – Linearity measurement with a long fibre Figure 12 – Placing the beginning of section D1 outside the attenuation dead zone |
39 | Annex A (normative) Multimode recirculating delay line for distance calibration Figure A.1 – Recirculating delay line |
40 | Figure A.2 – Measurement set-up for loop transit time Tb |
41 | Figure A.3 – Calibration set-up for lead-in transit time Ta |
43 | Annex B (normative) Mathematical basis |
46 | Bibliography |