BS EN 62149-5:2011
$142.49
Fibre optic active components and devices. Performance standards – ATM-PON transceivers with LD driver and CDR ICs
Published By | Publication Date | Number of Pages |
BSI | 2011 | 32 |
This part of IEC 62149 specifies performance on the transceiver modules for asynchronoustransfer-mode passive optical network (ATM-PON) systems recommended by the International Telecommunication Union (ITU) in ITU-T Recommendation G.983.1.
PDF Catalog
PDF Pages | PDF Title |
---|---|
7 | English CONTENTS |
9 | INTRODUCTION |
10 | 1 Scope 2 Normative references |
11 | 3 Term, definitions and abbreviations 3.1 Terms and definitions |
12 | 3.2 Abbreviations 4 Classification 5 Product definition 5.1 Description of transceiver module |
13 | 5.2 Description of applied form 5.3 Block diagram 5.4 Absolute limiting rating Figures Figure 1 – Functional block diagram (example) |
14 | 5.5 Functional specification Tables Table 1 – Absolute maximum ratings |
15 | Table 2 – Operating environment |
16 | Table 3 – Electrical and optical characteristics |
19 | Table 4 – Electrical interface characteristics (PECL type) |
20 | Table 5 – Electrical interface characteristics (LVTTL type) Table 6 – Electrical interface characteristics of alarm output voltage (PECL type) Table 7 – Electrical interface characteristics of alarm output voltage (LVTTL type) |
21 | Figure 2 – Relationship of phase between clock and data signals Table 8 – Electrical interface characteristics of shutdown input voltage (both PECL and LVTTL types) |
22 | Figure 3 – Recommended electrical circuit diagram for LVTTL-type interface (example) Figure 4 – Schematic drawing for defining launched optical power without input to transmitter |
23 | 6 Testing 6.1 Characterization testing Figure 5 – Schematic drawing for defining launched optical power without input to transmitter |
24 | Table 9 – Transmitter section characterization tests |
25 | 6.2 Performance testing Table 10 – Receiver section characterization tests |
26 | 7 Environmental specifications 7.1 General safety 7.2 Laser safety 7.3 Electromagnetic emission Table 11 – Performance testing plan |
27 | Annex A (informative) Measurement on tolerance to the reflected optical power (Table 3, Item 13) Figure A.1 – Model for incidence into ONU receiver Figure A.2 – An example system to measure tolerance to the reflected optical power |
28 | Figure A.3 – A recommended system to measure tolerance to the reflected optical power |
29 | Annex B (informative) Logic level of alarm and shutdown signal |
30 | Bibliography |