This part of IEC 62341 specifies the standard measurement conditions and measurement methods for determining the image sticking and lifetime of organic light emitting diode (OLED) display panels and modules. It mainly applies to modules.

PDF Catalog

PDF Pages PDF Title
6 English
CONTENTS
8 1 Scope
2 Normative references
3 Terms and definitions
9 4 Measuring configuration
4.1 General
4.2 Light measuring device (LMD)
5 Standard measuring conditions
5.1 Standard measuring environmental conditions
5.2 Standard measuring dark-room condition
5.3 Standard setup conditions
5.3.1 General
Figures
Figure 1 – Measuring system and arrangement
10 5.3.2 Adjustment of OLED display modules
5.3.3 Starting conditions of measurements
5.3.4 Test patterns
Tables
Table 1 – An example of measuring distance and radius size
11 5.3.5 Conditions of measuring equipment
6 Measuring methods of image sticking
6.1 Purpose
6.2 Measuring method
6.2.1 Measuring equipment
6.2.2 Measuring procedure
Figure 2 – Test pattern for image sticking
12 6.3 Analysis and report
6.3.1 Analysis
Figure 3 – An example of the burn-in image
14 6.3.2 Report
Table 2 – An example of typical value
15 7 Measuring methods of the luminance lifetime
7.1 Purpose
7.2 Measuring method
7.2.1 Measuring equipment
7.2.2 Measuring procedure
Table 3 – An example of the image sticking time with reference
Table 4 – An example of the image sticking data at target time
16 7.2.3 Estimation of luminance lifetime
Figure 4 – An example of luminance behavior in operation for an OLED display panel or module
17 7.3 Analysis and report
Figure 5 – An example of lifetime estimation with the extrapolation method
Figure 6 – An example of estimated lifetime depending on the time elapsed
18 Figure 7 – An example of Weibull distribution of lifetime
Table 5 – Examples of lifetime measurement
19 Annex A (informative) Calculation method of equivalent signal level
20 Figure A.1 – Measured 10 mA/cm2 to 80 mA/cm2 OLED degradation values and corresponding modelled functions with m = 1/1,7
22 Table A.1 – Examples of the maximum and the minimum equivalent signal levels (8 bits)
23 Figure A.2 – Accumulated colour intensity of IEC 62087:2011 10-min video loopin RGB subpixel format with equivalent signal distribution chart basedon the left images, respectively
24 Figure A.3 – Accumulated colour intensity of the IEC 62087:2011 10-min video loop in W, R, G, and B format, with equivalent signal distribution chart based on the left images, respectively
25 Annex B (informative) Acceleration test of lifetime measurement
Figure B.1 – Examples of Weibull distributions of accelerated lifetime test
26 Table B.1 – Summary of the acceleration test results in Figure B.1