Particular safety requirements for equipment to be connected to information and communication technology networks

Published By Publication Date Number of Pages
BSI 2017 56
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document applies to the interface of equipment designed and intended to be connected as a communication terminal to an information and communication technology (ICT) network termination.

This document does not apply to:

  • equipment covered by IEC 62368‑1 ; and

  • interfaces to other networks.

NOTE 1

An example of ‘other networks’ is a dedicated Home and Building Electronic Systems/Building Automation and Control Systems HBES/BACS network covered by EN 50491‑3 .

This document specifies the safety requirements of the interface to the ICT network only.

NOTE 2

See Annex D.

Requirements additional to those specified in this document may be necessary for

  • equipment intended for operation while exposed, for example, to extremes of temperature, to excessive dust, moisture, or vibration, to flammable gases, to corrosive or explosive atmospheres,

  • electro medical applications with physical connections to the patient.

The following requirements are not covered by this document:

  • functional safety of equipment;

  • functional reliability of equipment;

  • communication facilities with remote supply using hazardous voltage;

  • protection of equipment connected to ICT networks from functional damage.

PDF Catalog

PDF Pages PDF Title
2 National foreword
5 Annex ZA(normative)Normative references to international publicationswith their corresponding European publications
6 Annex ZZ(informative)Relationship between this European Standard and the safety objectives of Directive 2014/35/EU [2014 OJ L96] aimed to be covered
9 English
CONTENTS
11 FOREWORD
13 INTRODUCTION
14 1 Scope
2 Normative references
3 Terms and definitions
15 4 Safety requirements and compliance criteria
4.1 General
16 4.2 Interconnection of equipment
4.2.1 General requirements
4.2.2 Types of interconnection circuits
4.3 ES1 circuits
4.3.1 Limits
4.3.2 Protection against contact with ES1 circuits
4.4 ES2 circuits
4.4.1 Limits
4.4.2 Protection against contact with ES2 circuits
4.5 ES3 circuits
4.5.1 Limits
4.5.2 Protection against contact with ES3 circuits
17 4.6 Protection from hazards in the equipment for persons servicing ICT networks, and users of other equipment connected to the network
4.6.1 Protection from ES3
4.6.2 Separation of the ICT network from earth
4.6.3 Touch current to ICT networks
4.6.4 Summation of touch currents from ICT networks
4.7 Protection of equipment users from overvoltages on ICT networks
4.8 Protection of the wiring system of an ICT network from overheating
18 Annex A (informative) Relevant safety standards for the application of this document
19 Annex B (informative) ICT network voltages and signals
B.1 General
20 B.2 Contact with operating voltages on ICT networks
Figure B.1 – Current limit curves
22 Annex C (informative) Comparison of terms and definitions introduced in this document
C.1 General
C.2 Comparison of terms and definitions
23 Table C.1 – Comparison of terms and definitionsin IEC 60950-1:2005 and IEC 623681:2014
26 Table C.2 – Comparison of terms and definitionsin IEC 62151:2000 and IEC 62368-1:2014
29 Annex D (informative) Overview of networks
Figure D.1 – Overview of network
30 Bibliography
31 Français
SOMMAIRE
33 AVANT-PROPOS
35 INTRODUCTION
36 1 Domaine d’application
2 Références normatives
37 3 Termes et définitions
38 4 Exigences de sécurité et critères de conformité
4.1 Généralités
4.2 Interconnexion des équipements
4.2.1 Exigences générales
4.2.2 Types de circuits d’interconnexion
4.3 Circuits ES1
4.3.1 Limites
4.3.2 Protection contre les contacts avec les circuits ES1
4.4 Circuits ES2
4.4.1 Limites
4.4.2 Protection contre les contacts avec les circuits ES2
39 4.5 Circuits ES3
4.5.1 Limites
4.5.2 Protection contre les contacts avec les circuits ES3
4.6 Protection contre les dangers liés à l’équipement des personnes responsables de l’entretien des réseaux des TIC et des utilisateurs d’autres équipements connectés au réseau
4.6.1 Protection contre les ES3
4.6.2 Séparation entre le réseau des TIC et la terre
4.6.3 Courant de contact vers les réseaux des TIC
4.6.4 Somme des courants de contact provenant des réseaux des TIC
4.7 Protection des utilisateurs de l’équipement contre les surtensions des réseaux des TIC
4.8 Protection du câblage électrique d’un réseau des TIC contre les surchauffes
40 Annexe A (informative) Normes de sécurité pertinentes pour l’application du présent document
41 Annexe B (informative) Tensions et signaux du réseau des TIC
B.1 Généralités
42 B.2 Contact avec les tensions de fonctionnement des réseaux des TIC
Figure B.1 – Courbes représentant la limite de courant
44 Annexe C (informative) Comparaison des termes et définitions présentés dans le présent document
C.1 Généralités
C.2 Comparaison des termes et définitions
45 Tableau C.1 – Comparaison des termes et définitionsde l’IEC 60950-1:2005 et de l’IEC 623681:2014
49 Tableau C.2 – Comparaison des termes et définitionsde l’IEC 62151:2000 et de l’IEC 62368-1:2014
53 Annexe D (informative) Aperçu des réseaux
Figure D.1 – Aperçu du réseau
54 Bibliographie
BS EN 62949:2017
$198.66