BS EN IEC 60071-11:2022:2024 Edition

$189.07

Insulation co-ordination – Definitions, principles and rules for HVDC system

Published By Publication Date Number of Pages
BSI 2024 44
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
2 undefined
5 Annex ZA (normative)Normative references to international publicationswith their corresponding European publications
6 English
CONTENTS
8 FOREWORD
10 INTRODUCTION
11 1 Scope
2 Normative references
12 3 Terms and definitions
13 Tables
Table 1 ā€“ Classes and shapes of overvoltages, standard voltage shapesand standard withstand voltage tests
17 4 Symbols and abbreviations
4.1 General
18 4.2 Subscripts
4.3 Letter symbols
19 4.4 Abbreviations
5 Principles of insulation co-ordination
5.1 General
5.2 Essential differences between AC and DC systems
20 5.3 Insulation co-ordination procedure
5.4 Differences of withstand voltage selection in AC and DC systems
Table 2 ā€“ Comparison of the insulation co-ordination procedure of AC and DC systems
21 Figures
Figure 1 ā€“ Comparison of the selection between withstand voltagesfor AC equipment and for HVDC converter station equipment
22 6 Design procedure of insulation co-ordination
6.1 General
6.2 Arrester characteristics
6.3 Insulation characteristics
6.4 Determination of the representative overvoltages (Urp)
23 6.5 Determination of the co-ordination withstand voltages (Ucw)
6.6 Determination of the required withstand voltages (Urw)
24 Table 3 ā€“ Indicative values of ratios of required impulsewithstand voltage to impulse protective level
25 6.7 Determination of the specified withstand voltage (Uw)
7 Requirements for withstand voltage tests
8 Creepage distances
8.1 General
26 8.2 Base voltage for creepage distance
8.3 Creepage distance for outdoor insulation under DC voltage
8.4 Creepage distance for indoor insulation under DC or mixed voltage
8.5 Creepage distance of AC insulators
27 9 Clearances in air
28 Annex A (informative)Typical HVDC converter station schemes
29 Figure A.1 ā€“ Possible arrester locations in one pole of bipoleLCC converter station with 12-pulse converters in series
30 Figure A.2 ā€“ Possible arrester locations in one pole of bipolar of VSC converter stations
Figure A.3 ā€“ Possible arrester locations in symmetricalmonopole VSC converter stations
31 Table A.1 ā€“ Symbol description
32 Annex B (informative)Example of air clearances calculation
B.1 Introductory remarks
B.2 Calculated minimum air clearance for switching impulse stress
B.2.1 General
33 B.2.2 Example calculation
B.3 Calculated minimum air clearance for lightning impulse stress
B.3.1 General
34 B.3.2 Example calculation
35 Annex C (normative)Example of typical DC voltages with possible insulationlevels and corresponding air clearances
C.1 Introductory remarks
C.2 List of typical DC voltagesand possible insulation levels
C.3 Example of presumed switching impulse insulation levels and minimum air clearances
36 Table C.1 ā€“ Typical DC voltages and switching/lightning impulse withstand voltage
37 C.4 Example of presumed lightning impulse insulation levels and minimum air clearances
C.5 Possible/Presumed specified DC withstand voltages
C.5.1 General
Table C.2 ā€“ Correlation between presumed rated switching impulse withstandvoltages and minimum phase-to-earth air clearances
38 C.5.2 Specified DC withstand voltages
C.5.3 List of specified power frequency withstand voltages
Table C.3 ā€“ Correlation between presumed rated lightning impulse withstandvoltages and minimum phase-to-earth air clearances
39 Annex D (informative)Typical arrester characteristics
Figure D.1 ā€“ Typical arrester V-I characteristics
40 Annex E (informative)The Correlation of clauses between IEC 60071-11 and IEC 60071-5:2014
41 Bibliography
BS EN IEC 60071-11:2022
$189.07