BS EN IEC 60072-1:2022
$142.49
Rotating electrical machines. Dimensions and output series – Frame numbers 56 to 400 and flange numbers 55 to 1080
Published By | Publication Date | Number of Pages |
BSI | 2022 | 32 |
This document is applicable for the majority of rotating electrical machines for industrial purposes within the dimension range and output powers: Foot- mounted: shaft heights: 56mm to 400mm Flange- mounted: pitch circle diameter of flange: 55mm to 1080mm It specifies the fixing dimension, shaft extension dimensions and the assignment of output powers and frame sizes.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
5 | Annex ZA (normative)Normative references to international publicationswith their corresponding European publications |
7 | English CONTENTS |
9 | FOREWORD |
11 | 1 Scope 2 Normative references 3 Terms and definitions |
12 | 4 Symbols 4.1 Letter symbols for dimensions |
14 | 4.2 Dimensional sketches Figures Figure 1 – Dimensional sketches |
15 | 5 Designations of machines 5.1 Frame sizes 5.2 Flange numbers 5.3 Shaft extension 6 Location of the terminal box 6.1 Machines with feet 6.2 Machines without feet |
16 | 7 Fixing dimensions and tolerances 7.1 General 7.2 Foot-mounted machines Tables Table 1 – Dimensions for machines with shaft height from 56 mm to 400 mm |
17 | 7.3 Flange-mounted machines Table 2 – Dimensions and tolerances for flanges with pitch circle diameters from 55 mm to 1 080 mm |
18 | 8 Shaft end dimensions and tolerances 8.1 Shaft end dimenions |
19 | Table 3 – Dimensions and tolerances for shaft ends |
21 | 8.2 Parallelism of shaft to foot face 8.3 Parallelism of keyway to shaft axis 8.4 Lateral displacement of keyway 9 Methods of measurement 9.1 General Table 4 – Tolerance for parallelism shaft to foot face Table 5 – Tolerance for parallelism of keyway to shaft axis |
22 | 9.2 Shaft extensions run-out 9.3 Concentricity of spigot and shaft 9.4 Perpendicularity of mounting face of flange to shaft Figure 2 – Illustration of the measurement of shaft extensions run-out Figure 3 – Illustration of the measurement of concentricity |
23 | 9.5 Parallelism of shaft to foot face Figure 4 – Illustration of the measurement of perpendicularity Figure 5 – Illustration of the measurement of parallelism |
24 | 9.6 Parallelism of keyway to shaft axis 9.7 Lateral displacement of keyway 10 Preferred rated output values Figure 6 – Illustration of parallelism of keyway Figure 7 – Illustration of lateral displacement of keyway |
25 | Table 6 – Preferred rated output values |
26 | 11 Relationships between frame size, shaft extensions, rated outputs and flange numbers Table 7 – Totally enclosed fan-cooled induction motors (IC41) with squirrel-cage rotor |
27 | Table 8 – Totally enclosed fan cooled induction motors (IC41) with slip ring rotor |
28 | Table 9 – Ventilated induction motors (IC01) with squirrel-cage rotor Table 10 – Ventilated induction motors (IC01) with slip ring rotor |
29 | Annex A (informative)Additional relationships for frame sizes and output ratings Table A.1 – Relationships between frame size and rated output for 50 Hz increased safety “eb” |
30 | Annex B (informative)Additional recommended letters and dimensions Table B.1 – Additional frame letters and B dimensions in mm |
31 | Bibliography |