BS EN IEC 60076-22-5:2021
$142.49
Power transformers – Power transformer and reactor fittings. Electric pumps for transformers
Published By | Publication Date | Number of Pages |
BSI | 2021 | 30 |
This part of IEC 60076 covers electric pumps used in the cooling circuits of power transformers and reactors. It applies to electric pumps mounted on liquid immersed power transformers according to IEC 60076-1 and reactors according to IEC 60076-6 with and without conservator for indoor or outdoor installation.
It outlines the operation requirements for the electrical and hydraulic performance, mechanical design, routine testing and type testing. Additionally, performance and dimensions of preferred sizes of pump sets are specified in informative annexes.
The pumps covered in this document are rotodynamic pumps driven by a squirrel cage induction motor that is immersed in the insulating liquid.
Pump sets conforming to this document can be of in-line or end suction design.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
5 | Annex ZA(normative)Normative references to international publicationswith their corresponding European publications |
7 | English CONTENTS |
9 | FOREWORD |
11 | 1 Scope 2 Normative references |
12 | 3 Terms and definitions 4 Service conditions 4.1 General |
13 | 4.2 Degree of protection of electrical components (IP) 4.3 External corrosion protection 4.4 Internal corrosion protection 4.5 Insulating liquid characteristics 5 General characteristics and requirements 5.1 Rating plate information |
14 | 5.2 Direction of liquid flow and rotation 5.3 General mechanical requirements 5.4 Casing or enclosure |
15 | 5.5 Terminal box 5.6 Materials 5.7 Preferred sizes 5.8 Performance requirements 5.8.1 General |
16 | 5.8.2 Hydraulic performance 5.8.3 Hydraulic interchangeability Figures Figure 1 – Hydraulic interchangeability across the allowable operating range |
17 | 5.8.4 Electrical performance Figure 2 – Hydraulic interchangeability across an actual flow range |
18 | 5.8.5 Noise 5.9 Tests 5.9.1 General 5.9.2 List of tests 5.9.3 Routine tests |
19 | 5.9.4 Type tests |
20 | 5.9.5 Special tests |
21 | Annex A (informative)Preferred sizes of end suction pumps Figure A.1 – Dimensions of end suction pumps |
22 | Table A.1 – Dimensions of preferred sizes of end suction pumps (mm) |
23 | Annex B (informative)Preferred sizes of in-line pumps Figure B.1 – Dimensions of in-line pumps Table B.1 – Dimensions of preferred sizes of in-line pumps (mm) |
24 | Annex C (informative)Information required with enquiry, proposal and purchase order |
25 | Annex D (informative)Example of use of hydraulic interchangeability tolerances Figure D.1 – Pressure-flow characteristics |
26 | Figure D.2 – Tolerances as given in 5.8.3 applied to pump A |
27 | Figure D.3 – Pressure-flow characteristic of pump B superimposed on the characteristic of pump A Figure D.4 – Pressure-flow characteristic of pumps C and D superimposed on the characteristic of pump A |
28 | Figure D.5 – Flow ranges |
29 | Bibliography |