BS EN IEC 60099-8:2018 – TC:2020 Edition

$280.87

Tracked Changes. Surge arresters – Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV

Published By Publication Date Number of Pages
BSI 2020 163
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

NEW!IEC 60099-8:2017 is available as /2 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60099-8:2017 covers metal-oxide surge arresters with external series gap (externally gapped line arresters (EGLA)) that are applied on overhead transmission and distribution lines, only to protect insulator assemblies from lightning-caused flashovers.  This document defines surge arresters to protect the insulator assembly from lightning-caused over-voltages only. Therefore, and since metal-oxide resistors are not permanently connected to the line, the following items are not considered for this document: – switching impulse spark-over voltage; – residual voltage at steep current and switching current impulse; – thermal stability; – long-duration current impulse withstand duty; – power-frequency voltage versus time characteristics of an arrester; – disconnector test; – aging duties by power-frequency voltage. Considering the particular design concept and the special application on overhead transmission and distribution lines, some unique requirements and tests are introduced, such as the verification test for coordination between insulator withstand and EGLA protective level, the follow current interrupting test, mechanical load tests, etc. Designs with the EGLA’s external series gap installed in parallel to an insulator are not covered by this document. This second edition cancels and replaces the first edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: The Lightning discharge capability test has been completely re-written and re-named to Test to verify the repetitive charge transfer rating, Qrs with lightning discharges to reflect changes introduced in IEC 60099-4 Ed.3 (2014) regarding new methods for rating the energy and charge handling capability of metal-oxide arresters. In addition to testing to evaluate the performance of the MO resistors, procedures for evaluating the performance of the EGLA series gaps have been introduced. – Omissions from Ed. 1 of this standard have been included, notably an RIV test and a means for determining the thermal time constant of the SUV portion of the EGLA. – Definitions for new terms have been added – A number of NOTES in Ed. 1 have been converted to normative requirements Keywords: externally gapped line arresters (EGLA), lightning-caused over-voltages

PDF Catalog

PDF Pages PDF Title
91 National foreword
95 CONTENTS
99 FOREWORD
101 INTRODUCTION
Figures
Figure 1 – Configuration of an EGLA with insulator and arcing horn
102 1 Scope
2 Normative references
103 3 Terms and definitions
106 4 Identification and classification
4.1 EGLA identification
4.2 EGLA classification
Tables
Table 1 – EGLA classification – “Series X” and “Series Y“
107 5 Standard ratings and service conditions
5.1 Standard rated voltages
5.2 Standard rated frequencies
5.3 Standard nominal discharge currents
5.4 Service conditions
5.4.1 Normal service conditions
5.4.2 Special service conditions
Table 2 – Steps of rated voltages (r.m.s. values)
108 6 Requirements
6.1 Insulation withstand of the SVU and the complete EGLA
6.1.1 Insulation withstand of the housing of the SVU
6.1.2 Insulation withstand of EGLA with shorted (failed) SVU
6.2 Residual voltages
6.3 High current duty
6.4 Lightning discharge capability
6.5 Short-circuit performance of the SVU
109 6.6 Mechanical performance
6.7 Weather aging of SVU
6.8 Reference voltage of the SVU
6.9 Internal partial discharges
6.10 Coordination between insulator withstand and EGLA protective level
110 6.11 Follow current interrupting
6.12 Electromagnetic compatibility
6.13 End of life
7 General testing procedure
7.1 Measuring equipment and uncertainty
7.2 Test samples
111 8 Type tests
8.1 General
8.2 Insulation withstand tests on the SVU housing and on the EGLA with failed SVU
8.2.1 General
Table 3 – Type tests (all tests to be performed with or without insulator assembly; by manufacturer’s decision)
112 8.2.2 Insulation withstand test on the SVU housing
8.2.3 Insulation withstand tests on EGLA with failed SVU
113 8.3 Residual voltage tests
8.3.1 General
8.3.2 Procedure for correction and calculation of inductive voltages
114 8.3.3 Lightning current impulse residual voltage test
115 8.3.4 High current impulse residual voltage test
8.4 Standard lightning impulse sparkover test
116 8.5 High current impulse withstand test
8.5.1 Selection of test samples
8.5.2 Test procedure
117 8.5.3 Test evaluation
8.6 Test to verify the repetitive charge transfer rating, Qrs with lightning discharges
8.6.1 MO resistors
118 Figure 2 – Test procedure to verify the repetitive charge transfer rating, Qrs
119 8.6.2 Series gap
120 8.7 Short-circuit tests
8.7.1 General
Figure 3 – Test procedure to verify the repetitive charge withstand of the series gap
121 8.7.2 Preparation of the test samples
122 8.7.3 Mounting of the test sample
123 8.7.4 High-current short-circuit tests
125 8.7.5 Low-current short-circuit test
8.7.6 Evaluation of test results
127 Table 4 – Test requirements
128 Table 5 – Required currents for short-circuit tests
129 Figure 4 – Examples of SVU units
130 Figure 5 – Short-circuit test setup
131 8.8 Follow current interrupting test
8.8.1 General
8.8.2 "Test method A"
Figure 6 – Example of a test circuit for re-applying pre-failing circuit immediately before applying the short-circuit test current
133 8.8.3 "Test method B"
135 8.9 Mechanical load tests on the SVU
8.9.1 General
8.9.2 Bending test
139 Figure 7 – Thermo-mechanical test
140 Figure 8 – Example of the test arrangement for the thermo-mechanical test and direction of the cantilever load
141 Figure 9 – Test sequence of the water immersion test
144 8.9.3 Vibration test
145 8.10 Weather aging tests
8.10.1 General
8.10.2 Sample preparation
8.10.3 Test procedure
8.10.4 Test evaluation
146 8.10.5 Additional test procedure for polymer (composite and cast resin) housed SVUs
8.11 Radio interference voltage (RIV) test
9 Routine tests
9.1 General
147 10 Acceptance tests
10.1 General
10.2 Reference voltage measurement of SVU
Table 6 – Acceptance tests
148 10.3 Internal partial discharge test of SVU
10.4 Radio interference voltage (RIV) test
10.5 Test for coordination between insulator withstand and EGLA protective level
10.5.1 General
10.5.2 Steep front impulse test
Table 7 – Virtual steepness of wave front of steep front impulses
149 10.5.3 Standard lightning impulse sparkover test
10.6 Follow current interrupting test
10.6.1 General
150 10.6.2 Test procedure
10.6.3 Test sequence
10.6.4 Test evaluation
10.7 Vibration test on the SVU with attached electrode
10.7.1 General
10.7.2 Sample preparation
10.7.3 Test procedure and test condition
151 10.7.4 Test evaluation
152 Annex A (informative) Example of a test circuit for the follow current interrupting test
Figure A.1 – Example of a test circuit for the follow current interrupting test
153 Annex B (normative) Mechanical considerations
B.1 Test of bending moment
Figure B.1 – Bending moment – Multi-unit SVU
154 B.2 Definition of mechanical loads
Figure B.2 – Definition of mechanical loads
155 B.3 Definition of seal leak rate
Figure B.3 – SVU unit
156 B.4 Calculation of wind-bending-moment
Figure B.4 – SVU dimensions
157 B.5 Flow chart – Procedures of tests of bending moment for porcelain/cast resin and polymer-housed SVUs
Figure B.5 – Procedures of tests of bending moment for porcelain/cast resin and polymer-housed SVUs
158 Annex C (normative) Special service conditions
C.1 General
C.2 Temperature in excess of +40 °C or below –40 °C
C.3 Application at altitudes higher than 1 000 m
C.4 Fumes or vapours that may cause deterioration of insulating surface or mounting hardware
C.5 Excessive contamination by smoke, dirt, salt spray or other conducting materials
C.6 Excessive exposure to moisture, humidity, dripping water, or steam
C.7 Live washing of arrester
C.8 Unusual transportation or storage
159 C.9 Non-vertical erection and suspended erection
C.10 Wind speed > 34 m/s
C.11 Earthquake
C.12 Torsional loading of the arrester
160 Bibliography