Email:[email protected]

IEC 60728-3:2017 is also available as /2 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60728-3:2017 specifies the measuring methods, performance requirements and data publication requirements for active wideband equipment of cable networks for television signals, sound signals and interactive services. This fifth edition cancels and replaces the fourth edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) extension of upper frequency range limit for cable network equipment in the forward path from 1000 MHz to 1218 MHz (optional up to 1794 MHz); b) extension of upper frequency range limit for cable network equipment in the return path from 85 MHz to 204 MHz; c) integration and update of IEC 60728-3-1 content; d) integration and update of the Technical Specification CLC/TS 50083-3-3 content; e) deletion of specifications and test methods for obsolete analogue parameters; f) additional normative references; g) additional terms and definitions and abbreviations.

PDF Catalog

PDF Pages PDF Title
2 undefined
7 CONTENTS
10 FOREWORD
12 INTRODUCTION
13 1 Scope
2 Normative references
14 3 Terms, definitions, symbols and abbreviated terms
3.1 Terms and definitions
17 3.2 Symbols
19 3.3 Abbreviated terms
4 Methods of measurement
4.1 General
20 4.2 Linear distortion
4.2.1 Return loss
4.2.2 Group delay variation
21 4.3 Non-linear distortion
4.3.1 General
4.3.2 Types of measurements
22 4.3.3 Intermodulation
23 Figures
Figure 1 – Basic arrangement of test equipment for evaluation of the ratio of signal to intermodulation product
24 4.3.4 Composite triple beat
26 Figure 2 – Connection of test equipment for the measurement of non-linear distortion by composite beat
27 4.3.5 Composite second order beat
4.3.6 Method of measurement of non-linearity for pure digital channel load
29 Figure 3 – BER measurement test configuration
31 Tables
Table 1 – Measurement parameters for full channel load
33 Figure 4 – CINR measurement test setup
34 Figure 5 – Plot of CINR in dB curve (forward path) versus EUT channel output signal level in dB(V
35 4.3.7 Hum modulation of carrier
Figure 6 – Carrier/hum ratio
36 Figure 7 – Test set-up for local-powered objects
Figure 8 – Test set-up for remote-powered objects
37 Figure 9 – Oscilloscope display
38 4.4 Noise figure
4.4.1 General
4.4.2 Equipment required
4.4.3 Connection of equipment
Figure 10 – Measurement of noise figure
39 4.4.4 Measurement procedure
4.5 Crosstalk attenuation
4.5.1 Crosstalk attenuation for loop-through ports
4.5.2 Crosstalk attenuation for output ports
41 4.6 Measurement of noise power ratio (NPR)
4.6.1 General
Figure 11 – Measurement of crosstalk attenuation for loop through ports of multi-switches
42 4.6.2 Equipment required
4.6.3 Connection of equipment
Figure 12 – Characteristic of the noise filter
Figure 13 – Test setup for the non-linearity measurement
Table 2 – Notch filter frequencies
43 4.6.4 Measurement procedure
4.6.5 Presentation of the results
44 4.7 Immunity to surge voltages
4.7.1 General
4.7.2 Equipment required
4.7.3 Connection of equipment
Figure 14 – Presentation of the result of NPR
45 4.7.4 Measurement procedure
5 Equipment requirements
5.1 General requirements
5.2 Safety
5.3 Electromagnetic compatibility (EMC)
5.4 Frequency range
5.5 Impedance and return loss
Figure 15 – Measurement set-up for surge immunity test
46 5.6 Gain
5.6.1 Minimum and maximum gain
5.6.2 Gain control
5.6.3 Slope and slope control
5.7 Flatness
5.8 Test points
5.9 Noise figure
Table 3 – Example of return loss requirements
47 5.10 Non-linear distortion
5.10.1 General
5.10.2 Second-order distortion
5.10.3 Third order distortion
5.10.4 Composite triple beat
5.10.5 Composite second order
5.10.6 Maximum operating level for pure digital channel load
48 5.11 Hum modulation
5.12 Power supply
5.13 Environmental
5.13.1 General
5.13.2 Transportation
5.13.3 Installation or maintenance
5.13.4 Operation
49 5.13.5 Energy efficiency of equipment
5.14 Marking
5.14.1 Marking of equipment
5.14.2 Marking of ports
5.15 Requirements for multi-switches
5.15.1 Control signals for multi-switches
5.15.2 Amplitude frequency response flatness
5.15.3 Return loss
5.15.4 Through loss
5.15.5 Isolation
5.15.6 Crosstalk attenuation
50 5.15.7 Satellite IF to terrestrial signal isolation
5.16 Immunity to surge voltages
5.16.1 Degrees of testing levels
5.16.2 Recommendation of testing level degree
Table 4 – Parameters of surge voltages for different degrees of testing levels
Table 5 – Recommendations for degree of testing levels
51 Annexes
Annex A (normative) Test carriers, levels and intermodulation products
A.1 Two signal tests for second- and third-order products
A.1.1 Intermodulation products with test signals at frequencies ƒa and ƒb, see Table A.1
A.1.2 Signal levels
Figure A.1 – An example showing products formed when 2ƒa > ƒb
Table A.1 – Intermodulation products with two signals
52 A.2 Three signal tests for third order products – Intermodulation products with test signals at frequencies ƒa, ƒb and ƒc , see Table A.2 and Figure A.3
Figure A.2 – An example showing products formed when 2ƒa < ƒb
Figure A.3 – Products of the form ƒa ± ƒb ± ƒc
Table A.2 – Intermodulation products with three signals
53 Annex B (informative) Test frequency plan for composite triple beat (CTB), composite second order (CSO)
Table B.1 – Frequency allocation plan
55 Annex C (informative) Measurement errors that occur due to mismatched equipment
Figure C.1 – Error concerning return loss measurement
Figure C.2 – Maximum ripple
56 Annex D (informative) Examples of measurement channels
D.1 Operating frequency range 110 MHz to 1 006 MHz
D.2 Operating frequency range 110 MHz to 862 MHz
D.3 Operating frequency range 258 MHz to 1 218 MHz
57 Bibliography
BS EN IEC 60728-3:2018