BS EN IEC 60974-5:2019

$142.49

Arc welding equipment – Wire feeders

Published By Publication Date Number of Pages
BSI 2019 30
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 60974-5:2019 specifies safety and performance requirements for industrial and professional equipment used in arc welding and allied processes to feed filler wire. This document is applicable to wire feeders and to wire-feed controls that are stand-alone (separate from the welding equipment), housed together in a single enclosure or housed in a single enclosure with other welding equipment. The wire feeder can be suitable for manually or mechanically guided torches. This fourth edition cancels and replaces the third edition published in 2013 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: – changes induced by the publication of IEC 60974-1:2017; – addition of requirements for welding circuit connections in 6.9; – clarification of requirements and conformity in 6.3.1; – clarification of thermal requirements in Clause 9; – addition of requirements in relation to abnormal operation in Clause 10. This International Standard is to be used in conjunction with IEC 60974-1:2017.

PDF Catalog

PDF Pages PDF Title
2 undefined
5 Annex ZA(normative)Normative references to international publicationswith their corresponding European publications
6 Annex ZZ (informative)Relationship between this European standard and the safety objectives of Directive 2014/35/EU [2014 OJ L96] aimed to be covered
7 English
CONTENTS
9 FOREWORD
11 Scope
2 Normative references
3 Terms and definitions
13 4 Environmental conditions
5 Tests
5.1 Test conditions
5.2 Measuring instruments
5.3 Conformity of components
5.4 Type tests
5.5 Routine tests
14 Protection against electric shock
6.1 Insulation
6.2 Protection against electric shock in normal service (direct contact)
6.2.1 Protection provided by the enclosure
6.2.2 Capacitors
6.2.3 Automatic discharge of supply circuit capacitors
Table 1 – Minimum degree of protection
15 6.2.4 Isolation of the welding circuit
6.2.5 Welding circuit touch current
6.2.6 Touch current in normal condition
6.3 Protection against electric shock in case of a fault condition (indirect contact)
6.3.1 Protective provisions
6.3.2 Isolation between windings of the supply circuit and the welding circuit
6.3.3 Internal conductors and connections
16 6.3.4 Isolation of the welding circuit from the frame
6.3.5 Touch current in fault condition
6.4 Power supply to external devices connected to the welding circuit
6.5 Overcurrent protection of the supply circuit
6.6 Cable anchorage
6.7 Auxiliary power supply
6.8 Inlet openings
6.9 Welding circuit connections
17 6.10 Control circuits
6.11 Isolation of hanging means
7 Liquid cooling system
8 Shielding gas supply
18 9 Thermal requirements
10 Abnormal operation
10.1 General requirements
19 10.2 Stalled fan test
11 Mechanical provisions
11.1 Wire feeder
11.2 Enclosure
11.3 Handling means
11.4 Drop withstand
20 11.5 Tilting stability
11.6 Filler wire supply
11.6.1 Filler wire supply mounting
11.6.2 Wire spool retaining device
11.6.3 Filler wire overrun
11.7 Feeding
21 11.8 Protection against mechanical hazards
12 Rating plate
12.1 General
12.2 Description
22 12.3 Contents
Figure 1 – Principle of the rating plate of stand-alone wire feeder
23 13 Indication of wire-feed speed
14 Instructions and markings
14.1 Instructions
24 14.2 Markings
25 Annex A (normative)Determination of the variation in wire-feed speed
A.1 With respect to load change
A.2 With respect to supply voltage change
26 A.3 With respect to temperature rise
27 Annex B (informative)Example of a rating plate of a stand-alone wire feeder
Figure B.1 – Stand-alone wire feeder
28 Bibliography
BS EN IEC 60974-5:2019